AquatiControl Technology ELC-800r Operation And Maintenance Manual Download Page 3

 

ACT 2009 

- 3 -

INTRODUCTION

 

 
 

The AquatiControl Technology (ACT) Model ELC-800r is designed to provide 

the most accurate and reliable automatic water level control for swimming pools, spas, 
fountains, and spray pads. All of the user-friendly features incorporated into the system 
were designed with the operator in mind. 
 
 

The importance of precise control of water level in relation to proper filtration and 

water chemistry makes it possible to appreciate a device that will maintain levels within 
+/- 1/8 of an inch.  Installing the system requires basic tools and is accomplished quickly.  
Installation and operating instructions can be found on the following pages of this 
manual.  Line drawings for each sensing configuration can be found on our website at 

www.aquaticontrol.com

 
 

The ELC-800r should ship with the following contents: 

 
 (1) 

Control 

unit 

 

(1) 

Sensing Unit  

Standard Well 
Sight Glass 
Wet Well 
Surge Tank 
Deck Well 

 (1) 

Mounting 

Hardware 

 

(1) 

Operation and Maintenance Manual 

 (1) 

Warranty 

Card 

 
 

If any items are not found in this package, please call your closest distributor or 

the factory at (303) 762-9470. 

 

ELC-800r-SW 

ELC-800r-DW 

ELC-800r-SG 

ELC-800r-WW 

ELC-800r-ST 

Standard Well 

Deck Well 

Sight Glass 

Wet Well 

Surge Tank 

Sensing unit 

Sensing well 

Sensing box 

Sensing stick 

Sensing stick 

5' ½” 

Polytubing 

Sensing box 

25' remote 

cable 

Compression 

Fitting 

2- 1" Clic 

clamps 

1/2" PVC ball 

valve 

25' remote 

cable 

25' remote 

cable 

Mounting 
hardware 

2- 1/2" Parker 

fittings 

25' remote 

cable 

1/2"x close 

Nipple TBE 

Mounting 
hardware 

25' remote 

cable 

 

 

 

 
 

 

 
 

 

 

Summary of Contents for ELC-800r

Page 1: ...800r AUTOMATIC WATER LEVEL CONTROLLER AquatiControl Technology 3820 South Federal Blvd Sheridan Colorado 80110 Toll Free 877 755 8817 Fax 303 761 1499 www aquaticontrol com Serial No _________________...

Page 2: ...ACT 2009 2 TABLE OF CONTENTS Introduction 3 Installation 4 5 Wiring Diagram 6 Operation 7 8 Routine Maintenance 9 Troubleshooting 10 11 Warranty 12...

Page 3: ...is manual Line drawings for each sensing configuration can be found on our website at www aquaticontrol com The ELC 800r should ship with the following contents 1 Control unit 1 Sensing Unit Standard...

Page 4: ...ol The normal water level should sit approximately 1 from the bottom of the end cap The surge tank sensing unit is installed in the surge tank at normal operating water level with the included clic co...

Page 5: ...r setting to shut off a circulation pump in a low water situation A 24VAC contactor in line with the pump is needed and not supplied Also required is another sensing unit that will suit the needs of t...

Page 6: ...mal level sensor terminals s 10 11 12 Fill Valve attaches to fill valve terminals s 1 2 3 Dual Level Control Normal Level Sensor attaches to normal level sensor terminals s 10 11 12 Fill Valve attache...

Page 7: ...olenoid opening Fill on delay can be set from 15 seconds to 99 seconds DEFAULT 15 seconds MAX FILL TIME maximum time solenoid valve is allowed to stay on per fill cycle Max fill time can be set from 2...

Page 8: ...RESET PASSWORD enables password protection of settings NONE No password required to change settings NEW Enter up to 8 digit 0 9 password If the password is forgotten the user can perform a master res...

Page 9: ...t normally need to be cleaned SURGE TANK The Surge Tank Sensing Unit will not normally need to be cleaned however if the cap on the bottom of the sensing application becomes clogged with debris it can...

Page 10: ...hut off Turn on valve Defective sensor Replace sensor Sensing unit not set properly Readjust sensor to desired water level Wiring is incorrect in sensor junction box Check wiring connection Level ligh...

Page 11: ...RECTIVE ACTION Can not change settings Forgotten wrong password Reset ELC by turning the power on while holding the up and down arrows ELC does not allow pump to turn on ELC is still in alarm and need...

Page 12: ...or part which is returned transportation prepaid to the factory within one year of delivery to the original purchaser and which is proven defective upon examination ACT disclaims all liability for da...

Reviews: