AquaticLife 540372 Installation, Operation & Maintenence Manual Download Page 3

3

NOTE:

 Most sinks are pre-drilled with a 1 ¼" 

diameter hole that can be used for the faucet.

If your sink does not have a hole, you will need 

to drill one.

 

 

w w w . a q u a t i c l i f e . c o m

NOTE:

 If your model includes 

rubber plugs on any of the ports, 
it is now OK to remove the plug 
by simply pulling it out of the 
press fitting. 

MOUNTING THE FILTRATION UNIT

The Aquatic Life TI Filtration Unit is designed to be 
mounted to a secure surface. This will allow for the 
cartridges to easily be replaced as needed. 

The TI Module includes a metal bracket with screw holes 
for easy hanging. 

Use screws designed for the type of surface that the
TI Module will hang on. Once the TI Module is hanging
on the screws, tighten the screws to secure the TI Module 
to the surface. 

FAUCET INSTALLATION

The faucet may be installed on any flat surface.
Always check the underside of the desired location
to make sure it is clear of obstructions. 

Step 1

 – Determine the desired location for your faucet

on your sink surface.

Step 2

 – Place a piece of masking tape on the sink to 

determine hole location. Mark the center of the hole to be 
drilled on the tape. 

Step 3

 – Use a variable speed drill on low speed to drill

an 

1

/

8

" hole in the center of the marked location. 

Step 4

 – Enlarge the hole using a 

¼

" drill bit followed by a 

½

" drill bit. Using the different size bits to enlarge the hole 

will make it easier to achieve the final 

½

" diameter hole size.

  

Step 5

 – Assemble the faucet

as shown in the diagram. 

CAUTION! 

Once drilled, the hole in the sink 

might be sharp. Use caution when inserting the 
faucet stem into the hole. 

Chrome

Plate

Model: 540372

Twist-In 2-Stage Water Filtration Unit

Installation, Operation & Maintenance Guide

Rubber

Washer

Plastic

Washer

Lock

Washer

Hex Nut

Insert

Tubing

Sleeve

Hex Nut

Sink/Counter

Summary of Contents for 540372

Page 1: ...h cartridge connects to the filter housing by simply inserting and twisting It is important the cartridges be installed in the correct order to effectively filter the water Thank you for purchasing an Aquatic Life Twist In TI 2 Stage Water Filtration Unit When maintained properly this unit will provide you with years of high quality filtered water w w w a q u a t i c l i f e c o m Model 540372 Twi...

Page 2: ...ink Hand tightening this adapter is usually sufficient However if needed use a 1 adjustable wrench Connect To Cold Water Supply Only Model 540372 Twist In 2 Stage Water Filtration Unit Installation Operation Maintenance Guide Tools Materials Recommended for Installation 1 Adjustable Wrench Electric Drill 1 8 and Drill Bits for metal for faucet hole Masking Tape Pencil Screwdriver Teflon Tape Conte...

Page 3: ...cet may be installed on any flat surface Always check the underside of the desired location to make sure it is clear of obstructions Step 1 Determine the desired location for your faucet on your sink surface Step 2 Place a piece of masking tape on the sink to determine hole location Mark the center of the hole to be drilled on the tape Step 3 Use a variable speed drill on low speed to drill an 1 8...

Page 4: ...ng 4 Pull back on the tubing to ensure it is secure 5 Insert the locking blue clip back onto the end of the press fitting NOTE To remove a piece of tubing remove the blue clip and press down on the collet where the tubing enters the fitting While the collet is depressed remove the tubing from the fitting Collet Tubing Collet Flange O ring Blue Clip Tubing Push 2x Tubing Pull NOTE We recommend cutt...

Page 5: ...oming water supply This will be the Under Sink Water Adapter Step 2 Connect the other end of the yellow tubing to the port on the TI Module closest to the Sediment Cartridge Step 3 Cut the yellow tubing and install the Manual On Off Valve in a convenient place in the water supply line Step 4 Step 4 Connect one end of the blue tubing to the filtered water port on the TI module The other end of the ...

Page 6: ...lt in loss of filter performance and can shorten the lifespan of the filter UNIT MAINTENANCE 6 Month Maintenance TI Sediment Filter Cartridge Item 330377 TI Carbon Block Cartridge Item 330379 MAINTENANCE REMINDERS The Aquatic Life TI Cartridges include a place where you can write the date of installation to make it easy to know when a cartridge needs to be replaced NOTE The life span of the filter...

Page 7: ...quatic Life TI filtration products and accessories PRODUCT REGISTRATION Thank you for purchasing an Aquatic Life product we know you ll enjoy it BENEFITS OF REGISTRATION Confirmation of Ownership Provides a record in the event you need to contact us about your product in the future Your Safety Allows us to contact you with important product notifications Improved Product Support Helps us continue ...

Page 8: ...9710 Klingerman St S El Monte CA 91733 or electronic mail customersupport aquaticlife com Lifetime Products shall be allowed a reasonable period of time to investigate any warranty claim and to perform any testing Lifetime Products deems necessary to determine the cause of the defect This warranty shall be interpreted under the laws of the State of California Rev 04 13 16 THREE YEAR LIMITED WARRAN...