background image

LENS INSTALLATION

With the camera inside the housing, first disengage the pinion gear (key #12) by pulling and 

rotating the disc (key # 10) under the focus/zoom knob into the up position, install the lens 

prepared with its gears (if needed) through the port opening in the front of the housing. If using a 

gear always confirms that it is properly installed and aligned on the lens. Once installed, release 

the disc (key # 10) and rotate the focus / zoom control knob (Key # 11) to ensure that the gears 

are properly meshed, that their rotation is smooth and that it does not do not grind or bind.

Note: To avoid damaging the auto-focus mechanism of the camera when using standard AF-D 

type lenses, you should always set the Focus Control to “M” Manual for testing the proper meshing 

of focusing gears. This procedure is not required with AF-S type lenses.

MOUNTING THE PORT

Before mounting the port on the housing always ensure that the port O-ring is clean, lubricated and properly seated in its groove and that 

he sealing surface on the housing is clean and free of physical damage.

The AQUATICA AD7000 Digital Housing System features a bayonet mount (key #19) equipped 

with a locking mechanism (key # 18). If there is already a port or extension mounted on the 

housing and you wish to remove it, simply pull the lock lever (key 18a) downward until it stop, 

rotate the port counter clockwise and carefully pull out, and put it aside in a safe place with the 

port lens delicate surface protected.

To mount the port or extension ring simply:

1.  

Place the housing on its back on a soft steady surface. 

2.  

Place the port or extension ring inside the main port of the housing. Align one of the 

 

four alignment notches with the opening of the housing.

3.  

Place your hands on opposite sides of the port or extension ring.

4.  

Push with even force on both sides of the port or extension ring until you feel it snap 

 

into place. Make sure the bayonet is completely inside the housing.

5.  

Turn the port clockwise until it stops. Do not force, if there is too much resistance 

takes 

 

the port off, check the O-ring and retry. Once in, engage the port lock by pushing on the 

 

lock lever in (key 18b) as you would a button.

6.  

Check to ensure for the proper seating and sealing of the port or extension and that it is 

 

safely locked on the housing.

Note: It is recommended that you familiarize yourself with this mount by trying it without the 

camera; this will allows you to see the inside view of the bayonet mount and of the ports or 

extension rings in the housing.

CHANGING A LENS (REMOVING A LENS) 

By the front: Remove the port; the lens mounted gears may restrict the view and ease of ac

-

cess to the lens release button of camera. The AQUATICA AD7000 Digital Housing features a 

Lens Release Lever (key # 13) that is designed to trigger the lens release button of camera to 

allow easy removal of lens. To remove a lens, simply rotate Lens Release Lever (key # 13) to 

press the camera lens release, hold and turn the lens clockwise.

By the rear: remove the back, pull out the lens release lever (key # 13) and the M/S/C lever 

(key # 16) out of the way, lift and turn the disc under the focus/zoom knob (Key # 10) to 

disengage the pinion gear (key #12), release the saddle lock, remove hot shoe cable if using 

one and pull out the camera and lens assembly, replace lens and reinstall by reversing this 

procedure.

page 8

19

18a

18b

10

12

16

13

10

12

11

Summary of Contents for AD7000

Page 1: ...OPERATING MANUAL FOR THE AQUATICA PRO DIGITAL HOUSING FOR THE NIKON D7000 PRODUCT 20068...

Page 2: ...housing in a sturdy shock proof container and avoid travelling with the camera mounted inside the housing as impact forces especially on the external push buttons will be transferred to the camera Whe...

Page 3: ...22 Metering Pattern Selector button 23 Flash actuating exposure compensation lever 24 Video record button 25 Live View lever 26 Multi selector array 27 INFO activation button 28 Removable Viewfinder 2...

Page 4: ...n on the camera allowing easy removal of the lens 14 LENS RELEASE INTERNAL KNOB LEVER Applies pressure on the camera lens lock button 15 FOCUS MODE SELECTOR Press to select between AF A AF C and AF S...

Page 5: ...ti Selector to scroll select and magnify 37 RELEASE MODE DIAL SELECTOR UNLOCK BUTTON This button unlock the release mode dial so it can be rotated with the release mode dial knob key 7 38 AE AF LOCK L...

Page 6: ...ther brands of ports can also be used with an Aquatica port adapter H A comprehensive line of lens gears and related accessories PREPARATION OF THE HOUSING 1 Attach Grip Bracket to the housing The hou...

Page 7: ...ommand Dial the use of AF types of lenses is mandatory A comprehensive list of the lenses supported and their required gears is supplied at the end of this manual For the latest updated version of thi...

Page 8: ...n drawing at right 2 If using optical connectors then do not install the hot shoe HYB version as this will cancel the built in flash of the camera also make sure your built in flash on the camera is f...

Page 9: ...ort or extension ring inside the main port of the housing Align one of the four alignment notches with the opening of the housing 3 Place your hands on opposite sides of the port or extension ring 4 P...

Page 10: ...be and converter manufacturer for compatibility Set up instruction for iTTL operation Using the tip of a pen push all the switches to the ON up position this will activate the connections on your main...

Page 11: ...ll advantage of this feature To program from the CSM menu f1 Switch from this menu select the option with the light bulb symbol and Information display press OK to accept 2 The lever on the rear right...

Page 12: ...r When travelling by air remove the port This allows for equalization of the air pressure inside the housing to the external air pressure Failure to do so may cause serious damage to the ports by disl...

Page 13: ...an the O ring groove where the O ring sits with a cotton swab Be sure to remove any lint the cotton swab may leave behind Inspect the groove for damage 5 Wipe the part of the housing that the O ring s...

Page 14: ...ins no O rings just tough reliable performance from TLC For Sea Sea strobes For Ikelite Grip 17856 For Ikelite TTL Slave sensor Sea Sea Ikelite DS 200 Hartenberger 17802 Arm clamp to 1 ball Buoancy Co...

Page 15: ...R REASON IS NOT THE RESPONSABILLITY OF AQUATICA Therefore the appropriate insurance should be maintained by the user Warranty does not apply to replaceable seals or damages to impacts or abrasive surf...

Reviews: