FOCUSING MODE

NOTE :

 Select the proper focus mode with the focus mode button (key # 16) and the main command knob on the housing. For more 

detailed information concerning the operation of the different focus modes consult the Canon instruction book for the 

Canon 1Ds Mk 

III

.

USING THE HOUSING

Whenever changing ports or O-rings, it is highly advisable to perform a simple seal test without the camera inside. Strapping a weight to 

the housing and lowering the unit to a depth of 30 to 50 feet of water for at least 10 minutes will assure you that the seating of the new 

port or o-ring is proper. This test, though time consuming and often considered unnecessary, may save your camera equipment from 
irreparable water damage.The housing is now ready for the dive.

CAUTION:

 Never jump into the water with the housing. It is best to have the system handed to you after you have made your entry, or 

have it lowered to you on a rope. Make certain that ropes of other equipment stay clear of the system.

When photographing, be sure to respect the environment. Avoid damaging marine life or manipulating sea creatures to obtain a pleasing 
photo. The housing is slightly negatively buoyant so that you can lay it down on the bottom, but avoid laying it on living coral or other 
delicate marine life.

Changing the memory card

Always take care to thoroughly dry the housing before opening it to change memory card. Wipe the housing off with a dry towel. If 

possible it is suggested that the housing be blown dried by directing an air nozzle around the main o-ring before opening.

Rest the housing on its front with the lens facing down, be carefull to protect the port surface, release the top latch first then the two side 

latches simultaneously. Lift the rear part of the housing and place it in a secure location. This minimizes the possibility of any residual 

water falling into the housing and on to the camera when the housing is opened or damage to the sealing surface.

TRANSPORTING THE AQUATICA Pro Digital housing

Store the 

AQUATICA Pro Digital

 housing in a sturdy, shock proof container. 

When travelling by air, remove or loosen the port.

 This 

allows for equalization of the air pressure inside the housing to the external air pressure. Failure to do so may cause serious damage 

to the acrylic ports. Avoid travelling with the camera mounted in the housing. If you must do so, remove the lens as external impact or 
shocks can damage the camera bayonet mount.

CARE AND MAINTENANCE

Of the housing:

After each and every salt water dive, your housing system should be soaked or rinsed in fresh water. The housing system should soak 
in fresh water for at least 30 minutes. During this soaking period reach into the water and operate all the controls several times.

Be sure to remove the housing’s main o-ring and clean it after every use. Refer to Maintenance: Of the O-rings. To ensure that the hand 

grips won’t fuse on to the housing due to the exposure to salt water, it is also a good practice to occasionally remove the hand grips. 
Clean and lubricate the bolts with a small amount of WD-40.

WARNING:

 Use WD-40 carefully, sparingly and only on metal to metal surfaces. WD-40 can damage the acrylic on the ports, the 

optical surfaces on lens as well as the O-rings.

Of the Ports:

Care should be taken with the Dome Port and Macro Port to avoid scratches on the lens surface. The acrylic port is softer than glass 

so minor exterior scratches are often unavoidable. However, since the indices of refraction for acrylic and water are almost equal the 

scratches will not seriously impair image quality. Internal scratches(air side) must be avoided as they do not fill in with water and will 

affect the quality of the image.

Clean the dome using only products recommended for cleaning acrylic and a soft lint free cloth. Dust on the interior surfaces of the port 
can be removed with a soft camel hair brush or a blower brush. Caution must be taken when using aerosol devices as not to spray the 

lens material with the liquid propellant as this may seriously affect the optical properties of the port. Use of pressurize air from a dive 

tank is not recommended, the force of the air stream may easily dislodge a port or O-ring, It is advisable that ports should be removed 
and serviced after avery dive.

page 10

Summary of Contents for 20060

Page 1: ...OPERATING MANUAL FOR THE AQUATICA PRO DIGITAL HOUSING FOR THE CANON 1Ds Mk III PRODUCT 20060...

Page 2: ...malfunction Please read and follow the following precautions Store and transport the housing in a sturdy shock proof container and avoid travelling with the camera mounted inside the housing as impac...

Page 3: ...se knob 17 Lens Release knob lever 18 Port Release mechanism button 19 Hot shoe connector 20 Grips left right 21 Bayonet Flange 22 Grip s Accessories mounting holes 1 4 20 23 Latches x3 24 Quick contr...

Page 4: ...de can be used in conjunction with the AF DRIVE button 12 to activate the AEB function This button can also be used in conjunction with the AF DRIVE button 12 to activate the AEB function 12 AF DRIVE...

Page 5: ...2 INFO BUTTON Press to display information on shooting mode can be used to display histogram in playback mode 33 MENU BUTTON Press to activate menu display scroll using either the main 2 or quick 24 c...

Page 6: ...ION OF THE HOUSING 1 Attach Grip to the housing The housing comes with two grips for both right and left hand grips which should be installed on the sides of the housing with the supplied screws and A...

Page 7: ...the installation directions included with each gears carefully Since the aperture control is achieved through the Main or Quick Command Dial the use of lenses of the EF types is mandatory A comprehen...

Page 8: ...s hot shoe connector onto the hot shoe base of the camera as seen in drawing at right Before closing the housing always ensure that 1 The main O ring on the front half of the housing is clean lubrica...

Page 9: ...an lubricated and properly seated in its groove and that he sealing surface on the Housing is clean and free of physical damage The AQUATICA Pro Digital Housing System features a locking bayonet mount...

Page 10: ...the photographer current needs careful reading of the section 10 will provide useful information on how to optimize this camera for the underwater photographer s requirements 1 Push the Mode dial but...

Page 11: ...ng in a sturdy shock proof container When travelling by air remove or loosen the port This allows for equalization of the air pressure inside the housing to the external air pressure Failure to do so...

Page 12: ...ing groove where the O ring sits with a Q tip Be sure to remove any lint the Q tip may leave behind Inspect the groove for damage 5 Wipe the part of the housing that the O ring seals against with a cl...

Page 13: ......

Page 14: ...F 4 18457 18457 18482 NR Z 18709 Sigma 14mm F2 8 EX ASPHERICAL HSM 18462 18462 18480 NR F 18697 Sigma 15mm F2 8 FISHEYE Not Needed Not Needed 18480 Not Needed 18484 F 18715 Sigma 15 30mm F3 5 4 5 EX D...

Page 15: ...ER 18480 8 DOME SHADE F E 18480 8 DOME SHADE W A ZOOM FOCUS GEARS MAINTENANCE REBUILT O RING KITS EXTENSION RINGS Please visit our website at www aquatica ca for a complete selection of our Technical...

Page 16: ...the appropriate insurance should be maintained by the user Warranty does not apply to replaceable seals or damages to impacts or abrasive surfaces Warranty applies only to products purchased from aut...

Reviews: