background image

Aquatic 

 

Serenity DriftBath Owner's Manual & Installation Guide

1A

  

Ledge Installation - 1

1B  

Ledge Installation - 2

1C  

Apron Installation

1D

  

Wall Installation

1E  

Sunken Installation

INSTALLATION INSTRUCTIONS 

 STRUCTURAL PREPARATION:

Note: The bath should remain in its shipping carton until time of installation. 

1.

  

Literature dimensions are for reference only. Installation dimensions should be taken directly from the tub. An access 

panel of 16” x 16” minimum must be provided at the pump end of the tub allowing sufficient clearance to make final 

connections and for servicing the pump and power panel. Access may be through the wall or platform apron at the 

end of the unit. In the case of sunken installations, access should be made through the ceiling below.

 

IT IS THE INSTALLER’S RESPONSIBILITY TO PROVIDE SUFFICIENT SERVICE ACCESS. 

MAKE ABSOLUTELY CERTAIN THAT ACCESS PANELS AND/OR SERVICE OPENINGS ARE PROPERLY 

PLACED AND THAT ALL POSSIBLE AREAS WHERE SERVICE MAY BE REQUIRED ARE ACCESSIBLE.

2.

  

Install the drain fitting to the bath. 

THE DRAIN FITTING WILL PROTRUDE BELOW THE BASE OF THE TUB 

APPROXIMATELY 1 1/2”. 

Clearance must be provided for the drain by cutting away the subfloor (where possible) 

or by blocking below the tub as may be required. 

NOTE: 

Watertight installation of the drain and overflow is the 

installer’s responsibility. Drain and/or overflow leakage is not included in the warranty of this product.

  

WARNING: 

Factory skirts do not allow for blocking up of the tub base. All blocking must be solid and provide 

uniform support to the tub base.

3.  Tub must rest entirely on the base. 

DO NOT SUPPORT THE WEIGHT OF THE TUB BY THE RIM.

 Where leveling is 

required, and to reduce vibration noise, prepare a bed of wet mortar in area where tub is to be installed. Carefully 

level unit, ensuring that uniform support is given to all areas of the base and no portion of the lip is bearing weight.

4.  Frame out under the tub rim as shown in one of the illustrations below. 

NOTE:

 Due to the variety of installations 

possible, framing procedures other than those described may be required. Plumb in selected location using a level. 

Level front to back and across both sides. A ledge under the rim, or an apron without a ledge, may be constructed as 

required (see Diagram 1A and 1B). Where installation will be against a wall, stud wall framing should allow for wall 

sheathing material to run full length to the floor (see Diagram 1C). Install tub firmly against sheathing as dicated, with 

blocking below rim to prevent deflection or movement of tub. To prevent a rocking movement of tub after installation, it 

is important to have rim in contact, but not supported by blocking material.

5.  When placing the tub on a platform or cut out (see Diagrams 1A and 1D), the opening should be 1” smaller than the 

specified rim dimensions. Extreme care must be taken in this type of installation to ensure the tub will come to rest 

entirely on the base.

WARNING: 

ALL ELECTRICAL CONNECTIONS SHOULD BE MADE BY A LOCALLY LICENSED ELECTRICIAN/TECHNICIAN.

Summary of Contents for SERENITY DRIFTBATH

Page 1: ...MANUAL INSTALLATION GUIDE Note Read all instructions before proceeding with installation All specifications are 1 4 and are subject to change without notice Dimensions listed in inches mm SERENITY DR...

Page 2: ...ATION INSTRUCTIONS Structural Preparation 7 8 Plumbing 8 DriftBath with Chromatherapy LED Lights 9 OPERATION INSTRUCTIONS Bath side On Off Controls 10 DRIFTBATH USER INFORMATION 11 FCC CONSUMER INFORM...

Page 3: ...d reference when contacting the distributor to expedite warranty claims OWNER INFORMATION Model Name Serial Number Purchase Date Distributor AQUATIC Product Registration Information 8101 E Kaiser Blvd...

Page 4: ...to these instructions during the life of your DriftBath Failure to comply with these instructions may invalidate your warranty If you have any questions concerning installation operation maintenance o...

Page 5: ...may lead to unconsciousness with the possibility of drowning Never use the bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics na...

Page 6: ...tand for a few minutes 6 Plug in pump cord and run pump for 10 minutes 7 Inspect the tub completely Any defect must be reported to Aquatic prior to installation in order to have it covered by warranty...

Page 7: ...roduct WARNING Factory skirts do not allow for blocking up of the tub base All blocking must be solid and provide uniform support to the tub base 3 Tub must rest entirely on the base DO NOT SUPPORT TH...

Page 8: ...other finishing materials Apply a second bead of silicone between the first course of tile and the bath deck PLUMBING 1 After securing tub in place normal waste and overflow water spout and valves ar...

Page 9: ...tlet as in the above figure to a minimum 20 amp 120 vac dedicated circuit breaker which is GFCI protected not supplied INSTALLATION INSTRUCTIONS DRIFTBATH WITH CHROMATHERAPY LED LIGHTS TEST RESET Ligh...

Page 10: ...May Induce Hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6o F The symptoms of hyperthermia include...

Page 11: ...de reasonable protection against such interference in a residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does caus...

Page 12: ...MS CLEAN PLUS does not replace the necessity to purge your DriftBath system at least twice a month with a low foaming detergent and bleach SURFACE CLEANING Use common household non abrasive cleaners f...

Page 13: ...ies of bacteria causing the problem would require lengthy and costly laboratory testing however most experts believe the bacteria responsible is Serratia Marcescens These bacteria thrive on moisture d...

Page 14: ...oluble form that is especially noticeable with white tubs If high manganese in the water is present you may also notice black stains on white laundry If this occurs you need to contact the water suppl...

Page 15: ...r trips 1 Low voltage 2 Motor windings connected for wrong voltage 3 Inadequate ventilation 4 Wiring too small 1 Contact your electrician 2 Contact Aquatic 3 Refer to installer dealer 4 Contact your e...

Page 16: ......

Page 17: ...1 The tub is subject to damage during shipping by carriers faulty installation maintenance abuse accident or other damages 2 The tub is installed outdoors 3 The tub is not installed in accordance wit...

Page 18: ......

Page 19: ......

Page 20: ...AQUATIC Fax On Demand System Toll Free 877 618 7024 8101 E Kaiser Blvd Anaheim CA 92808 800 945 2726 Fax 866 544 5353 www aquaticbath com 8MANDBTH F O D 9009 02 13...

Reviews: