background image

CAUTION- POOL/SPA REFINISHING OPERATIONS

During pool refinishing or acid cleaning, the water flow through the heater must 

be shut off. Water flow to the heater must remain off until water chemistry is once 

again in balance and the water is clear in appearance.  Failure to follow these in-

structions may void heater warranty.

CONTROL IRRIGATION AND STORM RUN OFF

•  Control Irrigation: Irrigation water spray can damage heater components. 

Regardless of water quality, it is important that irrigation be directed 

away from the heat pump.

•  Prevent rain water runoff from pouring directly into the heater. The heater is 

designed to withstand normal rainfall, but solid streams of water from roof 

drip-lines may eventually damage heat pump components. 

•  If the heat pump resides beneath a roof edge, to promote heat pump longevity, 

a rain leader  (gutter), or  rain shield, will be necessary.

MAINTAIN PROPER CLEARANCES AROUND HEATER

•  For maximum efficiency, proper air flow clearances around heater must be 

maintained.

•  It is important to keep the area immediately adjacent to the heat pump clear 

of items such as shrubs and bushes, lawn furniture, chemicals containers, etc. 

These items can prevent air from circulating fully through the heater, and will 

result in inefficient operation or damage to the heat pump. 

•  In addition, do not place objects on top of the heat pump; doing so will block 

the air from exiting the heater, and will result in damage to the compressor 

and fan motor.

•  Proper clearances are also necessary in order to access the heater for service.

60”

2’’

6’

FRONT

TOP VIEW

FRONT

BACK

AIR

COIL

36”

12”

12”

12”

60”

2’’

6’

FRONT

TOP VIEW

FRONT

BACK

AIR

COIL

36”

12”

12”

12”

10

Operational & Programming Codes

 

FLO  No Water Flow Detected

 

This code appears whenever the circulating pump is off, or when    

the heater is not receiving correct water flow.

OFF  System is Off

 

This code appears whenever heater has been turned off via the mode   

 selector button, or when the temperature set point has been lowered 

below 45 

o

F.

CFI  Celsius/Fahrenheit Selection

 

This is a programming entry point to select in which format   

the water temperature will be displayed.

ULC  User Lock Code

 

This is a programming entry point; when activated, steps to the next   

 menu level: ELC.

ELC  Enter Lock Code

 

This a programming entry point; permits end user to select a secret     

 code, thereby limiting access to the owner settings.

CFO  Call Flex Options

 

This is a programming entry point; when used in conjunction with a 

Call/Flex option kit, permits the use of CALL or FLEX options. 

FS 

Heater in Defrost Mode

 

 

This code appears as a  normal display during periods of lower air 

temperatures. Sequence follows:

 

Heat-Only Defrost Sequence: Fan continues to run and compressor 

is off. Compressor  will restart when air coil temperature rises to 

approximately 38°F.

LOC

  This is a Service Entry point (not intended for use by the owner). 

The [LOC] code permits  service personal to enter a factory code for 

access to adjustable calibration and site-dependant setup parameters. 

Service adjustments are available to authorized installation and service 

personnel, only.

Failure  to  heed  the  following  may 

result  in  equipment  damage  and 

voiding of manufacturer’s warranty.

CAUTION !

Heat pumps contain no owner-serviceable components. Owner-

initiated adjustments, beyond the controller  “LOC” code, must 

not  be  attempted.  If  adjustments  are  deemed  necessary,  the 

owner should contact installing dealer or Aquatherm Customer 

Support at 239-482-0606.

5

Summary of Contents for AT115

Page 1: ...______ SERIAL_____________________________________________________ PURCHASE DATE_ ___________________________________________ INSTALLING CONTRACTOR____________________________________ POOL SPA HEAT PU...

Page 2: ......

Page 3: ...erved Except for a few minor owner capable maintenance items explained later in this manual repair and service of your heat pump must be performed only by licensed service personnel If you suspect you...

Page 4: ...e power supply panel and the disconnect switch located near the heat pump are both turned ON Is the code FLO displayed If so check to be sure that the circulating pump is operating and the filter is c...

Page 5: ...he desired water temperature for the POOL and or SPA 3 To Begin Heating A Verify MODE is set to HEAT HEA then depending on which body of water is to be heated use the POOL SPAselector key to select PO...

Page 6: ...operation whenever the actual displayed water temperature falls below the desired set point after an initial time delay of 4 minutes the unit will begin heating THE HEATER CONTROLLER HAS AN ANTI SHOR...

Page 7: ...heated is different Your heat pump comes equipped with two thermo stats One thermostat is for the pool and the other is for the spa Simply position the pool and spa isolation valves as directed by you...

Page 8: ...10 Operational Programming Codes FLO No Water Flow Detected This code appears whenever the circulating pump is off or when the heater is not receiving correct water flow OFF System is Off This code a...

Page 9: ...MENDED WATER CHEMISTRY STANDARDS 9 6 USER LOCK CODE OPTION ULC Heat pumps are shipped from the factory with the ULC option disabled En abling the ULC function permits the heat pump owner to restrict a...

Page 10: ...nu ously until the desired water temperature is attained This may take several hours to several days depending upon the size of the pool or spa and weather conditions If a time clock or similar device...

Reviews: