HEATING QUICK START AND STOP

1.   Verify Electrical Power is Present at Heater:

  A.   Ensure that the unit has electrical power connected; the heater controller 

display should be illuminated.

  B.  If the display is blank, be certain the electrical breaker, and heater disconnect, 

are switched to “ON.”

  C. For now, leave the water circulation pump OFF.

2.   Set the Heater Controls (Refer to Control Panel Layout, page 4)

     If heater is connected to a Call-Flex controller, please reference installation 

manual for details.

  A.   The user/owner settings can be made without water flowing. Once the 

heater has electrical power connected, with water not flowing, the display 

should read FLO.

  B.  Press the MODE button until the HEAT (HEA) indication displays. This 

will enable the remaining programming keys.

  C.  Using the POOL / SPA selector key, select the POOL mode. An illuminated 

POOL indicator light, located on the left side of the display, will confirm the 

POOL control has been selected. If heating only a spa, using the DOWN 

arrow key, lower the POOL temperature until OFF is displayed; then proceed 

to Step-“E.”

  D. Use the UP / DOWN arrow keys to set the desired water temperature for 

the POOL water.

  E.  If the heat pump will be used to heat a spa, use the POOL/SPA selector key 

to select SPA, then use the UP / DOWN arrow keys to set the desired water 

temperature for the SPA.  An illuminated SPA indicator light, located on 

the left side of the display, will confirm the SPA control has been selected. 

If heating only a POOL, using the DOWN arrow key, lower the SPA 

temperature until OFF is displayed.

  F.  The heat pump controls are now set to maintain the desired water temperature 

for the POOL and/or SPA.

3. To Begin Heating:

  A. Verify MODE is set to: HEAT (HEA); then, depending on which body of   

  water is to be heated, use the POOL / SPA selector key to select  POOL or  

  SPA.

  B.  Position water valves to flow water from the pool or spa, through the  

 

  heater,  and back to the  pool or spa.

  C. Start the water pump; the fan will start, and after 4-minute time delay the   

  unit will begin  heating. The selected body of water will be brought to 

       

 

 

 

 

 

                         2

   

5.  Replace the winterizing plug; thread the plug in clockwise until just snug, 

then  apply an additional 1/8 turn. To prevent insects and critters from entering 

the plumbing during the winterized period, partially reconnect the two (2) 

plumbing connection unions: couple each union one or two threads; this will 

permit condensation to drain, but will prevent  most insects and animals from 

entering the plumbing circuit.

6.  Next Season: To ready the heat pump for use, simply retighten plumbing 

connection unions.  Hand-tight is generally sufficient.

RECOMMENDED ANNUAL MAINTENANCE 

TO INCLUDE:

Clean all drains

Oil fan motor (if needed)

Inspect and clean coil

Check all electrical components

Check all relays for proper operation

Check and adjust water flow

Check water pressure controls

Check operation of thermal expansion valve

Check refrigerant levels

Check all incoming voltages

Check compressor starting and running amps

Check fan motor running amps

Check circulating pump running amps

Check air temperature differential

Check water temperature differential

Check pool chemical levels

Calibrate thermostat

Annual maintenance should be performed starting one year 

after the installation of the heater.  

Call Aquatherm Customer Service at 239-482-0606 

for recommendation of service company in your area.

13

Summary of Contents for AT115

Page 1: ...______ SERIAL_____________________________________________________ PURCHASE DATE_ ___________________________________________ INSTALLING CONTRACTOR____________________________________ POOL SPA HEAT PU...

Page 2: ......

Page 3: ...erved Except for a few minor owner capable maintenance items explained later in this manual repair and service of your heat pump must be performed only by licensed service personnel If you suspect you...

Page 4: ...e power supply panel and the disconnect switch located near the heat pump are both turned ON Is the code FLO displayed If so check to be sure that the circulating pump is operating and the filter is c...

Page 5: ...he desired water temperature for the POOL and or SPA 3 To Begin Heating A Verify MODE is set to HEAT HEA then depending on which body of water is to be heated use the POOL SPAselector key to select PO...

Page 6: ...operation whenever the actual displayed water temperature falls below the desired set point after an initial time delay of 4 minutes the unit will begin heating THE HEATER CONTROLLER HAS AN ANTI SHOR...

Page 7: ...heated is different Your heat pump comes equipped with two thermo stats One thermostat is for the pool and the other is for the spa Simply position the pool and spa isolation valves as directed by you...

Page 8: ...10 Operational Programming Codes FLO No Water Flow Detected This code appears whenever the circulating pump is off or when the heater is not receiving correct water flow OFF System is Off This code a...

Page 9: ...MENDED WATER CHEMISTRY STANDARDS 9 6 USER LOCK CODE OPTION ULC Heat pumps are shipped from the factory with the ULC option disabled En abling the ULC function permits the heat pump owner to restrict a...

Page 10: ...nu ously until the desired water temperature is attained This may take several hours to several days depending upon the size of the pool or spa and weather conditions If a time clock or similar device...

Reviews: