Use in the pond: 

ECO pumps are supplied complete ready for the operation in the pond (wet installation). 

Mount the swivel head (15) and the middle piece (16) plus the hose adapter (17) on the 

outlet adapter of the pump. NB: The gaskets have to be placed correctly between all 

joints. 

 

The pump can also be turned around in the housing, so the hose adapter comes out at 

the side of the pump housing. If you choose this solution, the housing part (5) has to be 

demounted and the supplied housing part with a hole (5) has to be mounted, hereafter 

the extension socket (14) has to be mounted directly on the pump and than turned to a 

horizontal position: now you can mount the ball-joint (15), middle piece (16), the univer-
sal hose adapter (17) and the plug for the outlet (1) on the top-housing. 

Use outside the pond: 

ECO pumps can also be installed outside the pond, f. ex. to a pressure filter or a larger 

filter systems. As the pumps are not self sucking, they always have to be installed 20 cm  

under the water level.  

 

Before use, the hoses have to be filled with water. Fasten the socket with thread (18), 

the universal hose  adapter (19) and the gaskets on the inlet and the outlet of the pump. 

Ensure, that everything is watertight, so that the system cannot suck air. 

 

For utilizing the water capacity optimal, you always have to use a hose / pipe with the 

largest possible diameter. Saw the unused diameter of the hose adapter of.  

 

For dry installation you may 

not

 use the ball-joint, as this is 

not

 100% watertight. 

Use in winter: 

When the temperature is not falling to under -5º C, the ECO pump can also operate in 
winter. In severe winters, where the temperature falls below -5º C, the pump has to be 

taken out from the pond. Clean the pump and the pump housing (pre-filter housing) 

properly. Check, if the pump or the cable are de-

fect. To prevent the gaskets from drying out, we 

recommend to store the pump wet, f. ex. in a 

bucket of water. The pump has to be started at 

least once a month for 10 minutes for preventing 

corrosion. 

 

Important ! 

The pump may not run dry, as the motor could 
be damaged and the bearings and the ceramic 

shaft could break down.  
Never use the pump in the pond without hous-
ing (pre-filter housing). Make sure that the 

hose is not bended, so that the water flow is 

blocked. 
When the pump is  in use, you have to main-
tain (clean) it regularly, depending on the pol-

lution level of the water. 

 

We recommend to rinse the housing (pre-filter 

housing) and clean the impeller ca. once a month 

(or even before, if the water flow reduces percep-

tible). Use a soft brush and clean water. 

 

See illustration A and B for demounting and 

mounting of housing, pump, impeller etc.

 

 

3

4

9

 m

m

 

 

1

7

6

 m

m

 

 

412 mm 

Summary of Contents for ECO 11000

Page 1: ...automatic thermal security device totally waterproof and their ceramic bearings guarantees a reliable and long lifetime ECO pumps are suitable for the operation of filter and pressure filters larger...

Page 2: ...the maximum depth on the data sheet of the pump The ECO pump has to be placed horizontal and not in the bottom sludge If neces sary you should use an elevation like f ex a socket of bricks The water...

Page 3: ...ccessories ECO pumps are available in 8 versions All ECO pumps have a Super Vortex impeller This special impeller ensures a large wa ter capacity and an easy transport of dirt particles up to 8 mm The...

Page 4: ...hat the impeller is running smoothly in the motor housing and that the gasket is mounted correctly before you fasten the 4 screws again Put the pump back to the pump housing and ensure that all parts...

Page 5: ...6 Lock clips 5 pcs AT001312 17 Universal hose adapter AT001334 7 Screw f motor shackle 2 pcs AT001314 18 Socket with thread for suction 1 for ECO 3600 11000 not illus trated AT001332 8 Motor shackle A...

Page 6: ...not suck air For utilizing the water capacity optimal you always have to use a hose pipe with the largest possible diameter Saw the unused diameter of the hose adapter of For dry installation you may...

Page 7: ...Aqua Tech offers a 24 month warranty period on the ECO pump series Send the certifi cate of warranty and a copy of the dated receipt to the supplier At any reclamation or warranty repair the certifica...

Page 8: ...ain clean it regularly depending on the pollution level of the water for ensuring the optimal operation Regulator Extern suction Optimal use of suction The extern suction of the Eco pumps can easily b...

Page 9: ...easily save up to 40 of the power consumption which usually is needed for the transportation of the indicated quantity of water compared to other pond pumps The pump can be recycled and is included t...

Page 10: ...nd bearings ECO s external suction can be connected to a skimmer a satellite pre filter or a pre filter and is easy to adjust so that the indicated distribution sucks from both the pump housing and fr...

Page 11: ...ng to the lifting height Use always the biggest possible hose or pipe diameter as this will ensure a low friction and avoid sharp angles or bends so that you will get the optimal pump performance If y...

Page 12: ...know how in the pump technology Developed with the purpose to create the optimal pump to a price everyone can effort ECO pumps are environment friendly and safe our resources Welcome to the world of...