IMPORTANT about SECURITY! 

 

The installation and operation of ECO pumps may only be carried out 

by persons over 16 years, who can understand the text of this users 
instructions correctly. 

 

Check that the power supply is identically with the one indicated on the pump. 
ECO pumps are provided with 10 m of grounded electrical safety cable and casted 
plug. The pump has to be connected to a grounded plug with earth leakage circuit 

breaker of 30 mA . 
Use only good quality grounded extension leads, flexes, plugs and the like. 
For ensuring optimal safety, the cable is casted into the pump housing and cannot be 
exchanged. If the cable is damaged, the pump may 

not

 be used any longer. 

When carrying out activities in or near the water, all devices which are immersed or 
in touch with the pond water should be switched off. 
The pump may 

not

 be lifted or pulled by the power supply cable. Mount an additional 

wire to the pump housing to lift the pump out of the water. 
The ECO pump is exclusively made for pumping water. Other floating media, burn-
able liquids or water over 40º C may 

not

 be pumped.  

The ECO pump may 

not 

run dry, as this could damage or even destroy the pump. 

Possible damages caused by dry run are 

not 

covered by the warranty. 

The ECO pump has to be installed at least 10 cm and not more than 2 m below the 
water level. See the maximum depth on the data sheet of the pump. 
The ECO pump has to be placed horizontal and 

not 

in the bottom sludge. If neces-

sary you should use an elevation like f. ex. a socket of bricks.  
The water temperature may not exceed 40º C, as this can damage the pump. How-
ever the automatic thermal security device will ensure, that the pump will be discon-

nected.  
When the pump and its connections are installed and checked completely (there may 
not be any air bubbles in the ducts), it can be connected to the power supply. 

NB: 

 

Before use: Check that the cable, the socket and the plug are dry and intact. 

 

Caused by safety reasons, repairs at the cable and the pump motor may only be carried 

out by the supplier or an authorized electrician (see the certificate of warranty). 

 

When the pump is installed outside the pond (dry-installation), all connections and con-

nection parts have to be watertight and equipped with gaskets. Fasten all connections 
and connection parts properly.  

 

The gaskets have a limited lifetime and have to be checked regularly. If the gaskets are 

porous or defect, they have to be replaced.   

 

For avoiding overheating, when the pump is installed outside the pond, the hoses / 

pipes should have following diameters:  

(Use always the hose / pipe with the biggest possible diameter).

 

ECO  3600 -   4800  min. 25 mm on outlet and 32 mm on suction side  

ECO 

7200 - 11000  min. 32 mm on outlet and 32 mm on suction side  

ECO  14000 - 18000  min. 40 mm on outlet and 40 mm on suction side  

ECO  22000 - 25000  min. 40 mm on outlet and 50 mm on suction side  

Summary of Contents for ECO 11000

Page 1: ...automatic thermal security device totally waterproof and their ceramic bearings guarantees a reliable and long lifetime ECO pumps are suitable for the operation of filter and pressure filters larger...

Page 2: ...the maximum depth on the data sheet of the pump The ECO pump has to be placed horizontal and not in the bottom sludge If neces sary you should use an elevation like f ex a socket of bricks The water...

Page 3: ...ccessories ECO pumps are available in 8 versions All ECO pumps have a Super Vortex impeller This special impeller ensures a large wa ter capacity and an easy transport of dirt particles up to 8 mm The...

Page 4: ...hat the impeller is running smoothly in the motor housing and that the gasket is mounted correctly before you fasten the 4 screws again Put the pump back to the pump housing and ensure that all parts...

Page 5: ...6 Lock clips 5 pcs AT001312 17 Universal hose adapter AT001334 7 Screw f motor shackle 2 pcs AT001314 18 Socket with thread for suction 1 for ECO 3600 11000 not illus trated AT001332 8 Motor shackle A...

Page 6: ...not suck air For utilizing the water capacity optimal you always have to use a hose pipe with the largest possible diameter Saw the unused diameter of the hose adapter of For dry installation you may...

Page 7: ...Aqua Tech offers a 24 month warranty period on the ECO pump series Send the certifi cate of warranty and a copy of the dated receipt to the supplier At any reclamation or warranty repair the certifica...

Page 8: ...ain clean it regularly depending on the pollution level of the water for ensuring the optimal operation Regulator Extern suction Optimal use of suction The extern suction of the Eco pumps can easily b...

Page 9: ...easily save up to 40 of the power consumption which usually is needed for the transportation of the indicated quantity of water compared to other pond pumps The pump can be recycled and is included t...

Page 10: ...nd bearings ECO s external suction can be connected to a skimmer a satellite pre filter or a pre filter and is easy to adjust so that the indicated distribution sucks from both the pump housing and fr...

Page 11: ...ng to the lifting height Use always the biggest possible hose or pipe diameter as this will ensure a low friction and avoid sharp angles or bends so that you will get the optimal pump performance If y...

Page 12: ...know how in the pump technology Developed with the purpose to create the optimal pump to a price everyone can effort ECO pumps are environment friendly and safe our resources Welcome to the world of...

Reviews: