24
www.
AQUASURE
USA
.com
818 N Mountain Ave #203c, Upland, CA 91786 | 800.661.0680 | [email protected]
CAUSE:
CORRECTION:
A
Water leaks from faucet spouts
Adjust the faucet by turning the tee bar located under
the handle to provide a small amount of free play in
the handle when shut off. Should this not work, repair
or replace the faucet.
B
Water leaks from beneath the handle
Repair or replace the faucet.
6. Faucet leaks or drips
CAUSE:
CORRECTION:
A
Water is shut off at stop valve
Open main stop valve.
B
Flowlok is set to off position
Make sure Flowlok main lever is in open position.
Lever should be lowered.
C
Output line is crimped
Reroute the line so they are not restricting the water
from existing the faucet.
D Tank is not pre-charged
Empty out the tank and recharge the tank pressure
E
Tank is defective or does not hold pressure
Replace the tank
F
Tank is not filled with water yet
Allow holding tank to refill for about an hour or so
before using the water.
G Insufficient water pressure
Incoming water pressure must be above 40 psi. Install
a booster pump or permeate pump
H Incorrect installation
Check the installation guide and make sure all the
steps are installed properly.
7. Little to no water at dispensing faucet.
CAUSE:
CORRECTION:
A
Air bubble trapped inside the housing
Purge the air by tilting the system on one side, shut
off the tank ball valve and turn on the dispensing
faucet for about 1 minute. Repeat 3 or 4 time to
purge out all the air.
8. System makes humming noise
CAUSE:
CORRECTION:
A
Insufficient water pressure
Incoming water pressure must be above 40 psi. Install
a booster pump or permeate pump
B
Lower water temperature
Cold water affects the performance of system. Install
a booster pump or permeate pump to compensate for
lower water temperature.
9. Tank takes a long time to fill
CAUSE:
CORRECTION:
A
Insufficient water pressure for system to shut off Incoming water pressure must be above 40 psi. Install
a booster pump or permeate pump
B
Feed water valve is not open fully
Open feed water valve fully to lessen the restricted
flow
C
Sediment/Carbon pre-filters is clogged
Replace the filter
10. System slow to shut off