AquaStar Ultimate Ozone U3000 Kit Installation And User Manual Download Page 4

The Ultimate Ozone™ system uses an air pump to move air through a corona discharge ozone generator.  Our model 

U1000 is capable of outputting 1 gram per hour of ozone which is suitable for treating up to 40,000 gallon pools. 

Ozone is moved into the pool/spa through compatible 1/4'' tubing that is to be connected to 

the 1/4'' Hose Barb Outlet Fitting on the bottom of the U1000 and connected to a FlowStar™ 

Ozone Compatible Skimmer (Aquastar Model # SKR1xx-OZ). (See Figure 2.2)

The ozone compatible tubing should be run inside 1'' conduit/PVC pipe; sweeps should be 

used for any 90° turns.   A junction box must be installed on the deck to avoid water back-

flow (AquaStar Model #JBRxxx or JBSxxx).  Connect the conduit to the 1” port located at 

the bottom of the junction box.  Connect the ¼” ozone compatible tubing to the ¼” hose 

barb located on the bottom of the ozone unit and feed the tubing through the conduit to the 

junction box.

Another line of conduit should be run from the second 1” socket port located on the bot-

tom of the junction box to the 1” socket port located on the bottom of the Ozone compatible 

FlowStar™ skimmer’s throat.  (See Figure 2.3).   Remove the bubble plate, by unscrewing the 

two screws located on either side, from inside the skimmer’s throat and feed the ozone com-

patible tubing from the junction box to the skimmer.

Connect 2'' PVC pipe to the 2'' socket located on the bottom of the throat of the FlowStar™ 

skimmer, the PVC pipe must be at least 2'4'' below water line and no greater than 4 feet, See Figure 2.3.  

BLOW OUT OZONE TUBE TO CLEAR LINE OF WATER AND DEBRIS BEFORE ATTACHING OZONE DIF-

FUSER STONE.

Attach the ozone diffuser stone to the ozone compatible tubing and feed the diffuser stone into the 2” pipe (contact 

chamber).  The ozone diffuser stone should rest a minimum of three quarters of the way down the pipe.  Secure the 

bubble plate back into the throat of the skimmer by fastening both screws.  

The contact chamber will allow water in through a returning fitting, (included with SKR1xx-OZ) that fits into 2” pipe 

(33xx and BPxxx).  Install the fitting housing so that it is flush with the pool’s finish and thread in bubbler plate (BPxxx). 

NOTE: THE THREAD IN BUBBLER PLATE IS NOT A SUCTION OUTLET AND DOES NOT NEED TO BE A 

VGB COMPLIANT DRAIN TO COVER THE OPEN PIPE.

General System Overview and Installation

Figure 2.1 Overview of System

Figure 2.2 Front View of System

3

Ultimate Ozone™ Installation and User’s Guide

Figure 2.3 

Skimmer Ozone Ports

 

Rev: 030717

Summary of Contents for Ultimate Ozone U3000 Kit

Page 1: ...ULTIMATE OZONE OZONE GENERATION SYSTEM MODELS U1000 and U3000 Kit INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS ...

Page 2: ...LATION AND OPERATION The installation operation and servicing of this ozone system can only be carried out after reading and understanding the information contained in this guide The installation must be performed in accordance with all federal state and local regulations and codes This product must be wired in conjunction with a properly grounded Ground Fault Circuit Interrupter GFCI Only three 3...

Page 3: ...1000 Corona Discharge Pump 1 unit OZG4017 Ozone Diffuser Stone 1 unit OZG4016 Ozone Compatible 1 4 Tubing 100 ft Limited Warranty Aquastar Pool Products Inc offers a one year limited warranty on the Ultimate Ozone See warranty sec tion for details and limitations SECTION 2 Installation Location Ultimate Ozone units are designed for wall mounting Mount the unit in a clean protected area either indo...

Page 4: ...2 3 Remove the bubble plate by unscrewing the two screws located on either side from inside the skimmer s throat and feed the ozone com patible tubing from the junction box to the skimmer Connect 2 PVC pipe to the 2 socket located on the bottom of the throat of the FlowStar skimmer the PVC pipe must be at least 2 4 below water line and no greater than 4 feet See Figure 2 3 BLOW OUT OZONE TUBE TO C...

Page 5: ...eed 8 0 ppm As Br2 when bathers are present 4 Ultimate Ozone Installation and User s Guide Maintenance The Ultimate Ozone requires little maintenance For a properly prerforming system ensure that the skimmer basket is regulary checked and kept clean from excess debris Every month all visual components should be inspected If anything is found to be damaged it should be replaced SECTION 4 Troublesho...

Page 6: ...rts thereof to or from AquaStar Pool Products Inc s Technical Service Department Also AquaStar Pool Products Inc is not liable for any loss of time inconvenience incidental expenses such as telephone calls labor or material charges incurred in connection with the removal or replacement of the equipment or any other incidental or consequential damages including but not limited to damage to pool equ...