Ultimate Ozone™ Installation and User’s Guide

Rev: 030717

PLEASE READ, FOLLOW, AND SAVE THESE INSTRUCTIONS!

Attention Installer:

 Read this manual completely before attempting installation. Failure to follow these 

instructions could result in injury or death and will void the product warranty. Consult AquaStar Pool 

Products with any question regarding this product. This guide must be left with the pool owner.

Attention User: 

This guide contains important information about the installation, operation and safe use 

of this product. Please retain this guide for future reference. 

 

 

        FAILURE TO FOLLOW ALL INSTRUCTIONS AND WARNINGS CAN RESULT IN SERIOUS 

BODILY INJURY OR DEATH. 

THIS OZONE SYSTEM SHOULD BE INSTALLED AND SERVICED ONLY BY A 

QUALIFIED POOL PROFESSIONAL.

            

        

DO NOT INHALE OZONE GAS PRODUCED BY THIS PRODUCT

. Short-term inhalation 

of high concentrations of ozone and long-term inhalation of low concentrations of ozone can cause 

serious harmful physiological effects.  The ozone system box and ozone stone must be installed in outdoor 

locations only, or indoor locations with forced air ventilated rooms and indoor pool and spas areas must 

be ventilated in accordance with ASHRAE Standard 62.1 2013, Ventilation for Acceptable Indoor Air 

Quality, and/or applicable local codes.

IMPORTANT SAFETY INSTRUCTION! PLEASE READ PRIOR TO 

INSTALLATION AND OPERATION!

 

 

        The installation, operation and servicing of this ozone system can only be carried out 

after reading and understanding the information contained in this guide. The installation must be 

performed in accordance with all federal, state and local regulations and codes.

 

 

        This product must be wired in conjunction with a properly grounded, Ground Fault 

Circuit Interrupter (GFCI).

 Only three (3) wire grounded cord suitable for outdoor use should be used to 

connect this product. For outdoor use, a suitable watertight cord connector must be used. If an extension 

cord is necessary, a cord with a proper outdoor rating must be used. Locate the cord so that it will not be 

tripped over or pulled. If in doubt consult a qualified electrician. 

 

 

        Receptacles that provide power for this product must be located at least 10 feet 

(3.0 meters) from the inside wall of the pool or spa. The ozone unit box must be installed at least 5 feet 

(1.5 meters) from the inside wall of the pool or spa and no less than one foot above overflow water level to 

prevent water from contacting electrical equipment. 

 

 

        ELECTRIC SHOCK HAZARD! Disconnect from power source before opening the ozone 

system box for any reason. Failure to do so can result in serious injury or death.

 

 

        Never attempt any servicing while unit is wet. Do not store or use gasoline, chemicals 

or other flammable liquids or vapors near this or any other appliance. Do not permit children to use this 

product.

ONLY use ozone compatible tubing and ozone stone. Never replace with metal tubing.

1

Summary of Contents for Ultimate Ozone U3000 Kit

Page 1: ...ULTIMATE OZONE OZONE GENERATION SYSTEM MODELS U1000 and U3000 Kit INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS ...

Page 2: ...LATION AND OPERATION The installation operation and servicing of this ozone system can only be carried out after reading and understanding the information contained in this guide The installation must be performed in accordance with all federal state and local regulations and codes This product must be wired in conjunction with a properly grounded Ground Fault Circuit Interrupter GFCI Only three 3...

Page 3: ...1000 Corona Discharge Pump 1 unit OZG4017 Ozone Diffuser Stone 1 unit OZG4016 Ozone Compatible 1 4 Tubing 100 ft Limited Warranty Aquastar Pool Products Inc offers a one year limited warranty on the Ultimate Ozone See warranty sec tion for details and limitations SECTION 2 Installation Location Ultimate Ozone units are designed for wall mounting Mount the unit in a clean protected area either indo...

Page 4: ...2 3 Remove the bubble plate by unscrewing the two screws located on either side from inside the skimmer s throat and feed the ozone com patible tubing from the junction box to the skimmer Connect 2 PVC pipe to the 2 socket located on the bottom of the throat of the FlowStar skimmer the PVC pipe must be at least 2 4 below water line and no greater than 4 feet See Figure 2 3 BLOW OUT OZONE TUBE TO C...

Page 5: ...eed 8 0 ppm As Br2 when bathers are present 4 Ultimate Ozone Installation and User s Guide Maintenance The Ultimate Ozone requires little maintenance For a properly prerforming system ensure that the skimmer basket is regulary checked and kept clean from excess debris Every month all visual components should be inspected If anything is found to be damaged it should be replaced SECTION 4 Troublesho...

Page 6: ...rts thereof to or from AquaStar Pool Products Inc s Technical Service Department Also AquaStar Pool Products Inc is not liable for any loss of time inconvenience incidental expenses such as telephone calls labor or material charges incurred in connection with the removal or replacement of the equipment or any other incidental or consequential damages including but not limited to damage to pool equ...