ATTENTION INSTALLER
RISK OF SUCTION ENTRAPMENT.
Only install this pump on suction systems that have been evaluated
and found in conformance with the Virginia Graeme Baker Pool & Spa Act, and all warning notices and
instructions that accompany the product.
FAILURE TO PROTECT USERS FROM ALL FIVE SUCTION
ENTRAPMENT HAZARDS CAN RESULT IN SERIOUS INJURY OR DEATH.
This pump is not equipped with Automatic Pump Shut-off or Safety Vacuum Release System (SVRS)
protection. It does not protect against body or limb entrapment, disembowelment, or hair entanglement.
RISK OF HAZARDOUS PRESSURE.
Before installing this pump, read and follow all warning notices and
instructions that accompany the product.
FAILURE TO FOLLOW WARNINGS AND INSTRUCTIONS MAY
RESULT IN PERSONAL INJURY OR DEATH.
Do not install pump on/off switches or controls near filters.
Trapped air in the system can cause the filter
lid to be blown off when the pump starts up, which can result in death, or serious injury.
Do not use with storable pools.
A permanently-installed pool is constructed in or on the ground or in a
building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is
capable of being readily disassembled for storage and reassembled to its original integrity.
This pump is capable of high pressure that may exceed the limits of other equipment.
Confirm all
equipment installed on the pressure-side of this pump has a working pressure rating of 50 psi or greater. If
the working pressure of other equipment does not meet this requirement, do not install this pump unless
the other equipment is removed or replaced first.
Separation Hazard.
Failure to follow safety and operation instructions could result in violent separation of
pump components. Strainer cover must be properly secured to pump housing with strainer cover lock ring.
Pressure Testing Hazards
. To minimize the risk of severe injury or death, the pump should not be subjected
to the piping system pressurization test. Do not connect the system to an unregulated city water system or
other external source of pressurized water producing pressures greater than 35 PSI. Local codes may require
the pool piping system to be subjected to a pressure test, however, these requirements are generally not
intended to apply to the pool equipment such as pumps, filters, heaters, or in-line sanitizing systems.
NEVER PRESSURE TEST WITH COMPRESSED AIR!
1.2 INSTALLATION SAFETY INSTRUCTIONS
CONTINUED
HidroShop.mx