    Pipeline Pump Instructions - 

AquaStar Pool Products

HidroShop.mx

Summary of Contents for Pipeline Pumps PLP150B

Page 1: ...LATION AND USER S GUIDE All rights reserved Copyright AquaStar 2022 U S Patent Pending IN029 081822 FOR YOUR SAFETY Read understand and follow all warning notices and instructions before installing us...

Page 2: ...H i d r o S h o p m x...

Page 3: ...ING INSTRUCTIONS 16 4 3 1 SET TIME 16 4 3 2 SPEED SET UP 16 4 3 3 SCHEDULE SET UP 17 4 3 4 VARIABLE SPEED SET UP 17 4 3 5 LANGUAGE SET UP 17 4 3 6 NO FLOW SET UP 18 4 3 7 PUMP PRIMING SET UP 18 4 3 8...

Page 4: ...4 Pipeline Pump Instructions AquaStar Pool Products H i d r o S h o p m x...

Page 5: ...jury do not permit children to use or climb on this product Closely supervise children at all times Components such as the filtration system pumps and heaters must be positioned to prevent children fr...

Page 6: ...tive and the problem must be corrected by a qualified service representative before using Connect the motor bonding lug to the pool or spa electrical bonding structure Failure to bond pump to pool or...

Page 7: ...isassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity This pump is capable of high pressure t...

Page 8: ...IN DEATH OR SERIOUS INJURY BEFORE USING THIS PUMP CONFIRM THE SUCTION SYSTEM IS COMPLIANT WITH THE VIRGINIA GRAEME BAKER POOL SPA SAFETY ACT VGBA AND THE FOLLOWING GUIDELINES THE SUCTION SYSTEM MUST P...

Page 9: ...law s May 24 2021 effective date Drain covers compliant with the previous version of the U S Consumer Product Safety Standard may also be used in compliance with the VGBA those manufactured or import...

Page 10: ...or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the pump by a person responsible for their safety NEVER run the...

Page 11: ...pump speeds and schedules with the free AquaStar PipeLine Connect App MOTOR FEATURES High Efficiency Permanent Magnet Synchronous Motor PMSM Operates at lower temperatures due to high efficiency Desi...

Page 12: ...ce 8 Make sure that floor drainage is adequate to prevent flooding 3 1 PUMP LOCATION 3 0 INSTALLATION INSTRUCTIONS CONTINUED Install all electrical controls at equipment pad such as on off switches ti...

Page 13: ...local codes and ordinances Improper installation will create an electrical hazard which could result in death or serious injury to users installers or others due to electrical shock and may also caus...

Page 14: ...the Bonding Lug on the side of the motor as shown in Figure 4 in accordance with the National Electrical Code 2 Use no smaller than 8 AWG conductor for US installations and no smaller than 6 AWG cond...

Page 15: ...p at the breaker 4 Be sure the control panel display is active and press the Run button to begin priming See Figure 5 5 Close the air bleed valve on the pool filter once all air has escaped 6 The pump...

Page 16: ...n before modifying any pump setting 4 3 1 SET TIME Time is set using a 24 hour clock hr min Press Menu button to enter the settings menu Use buttons Up and Down to highlight Time and press Enter Press...

Page 17: ...repeatedly press to return to the home screen Note Schedule settings can also be adjusted within the AquaStar Pipeline Connect App 4 3 4 VARIABLE SPEED SET UP This function allows the pump to cycle t...

Page 18: ...t the Priming option and press Enter Use buttons Up and Down to highlight 9 The Function option and press Enter to Enable or Disable this feature which is set to Enabled by default The Priming Time op...

Page 19: ...VSPV WiFi network enter the IP address 192 168 8 1 88 into a web browser Select SSID Password on the right side of the screen Enter your new SSID Name Password and Repeat Password then press Submit Di...

Page 20: ...de 3 4 6 and 16 1 247 Replica address Isolated A B data bus without 120 ohm terminal resistor 4 3 11 SYSTEM RESET This function will reset all the user settings to the factory default and can not be u...

Page 21: ...0 1 4 Enabled Disabled Default Disabled hr mm Default 07 30 hr mm Default 18 30 800 3400 RPM Default 0900 RPM 800 3400 RPM Default 2900 RPM 10 500 RPM Default 100 RPM 0 5 9 9s Default 1 0s Language En...

Page 22: ...MANCE SPECIFICATIONS Note Refer to the pump motor label and all national and local electrical codes for specific electrical requirements and specifications 0 10 20 30 40 50 60 70 80 0 20 40 60 80 100...

Page 23: ...bled and checked for obstructions Contact a qualified repair professional OH Motor temperature overheating Have a licensed electrician Ensure that the voltage at motor terminals is no more or less tha...

Page 24: ...ician Check voltage at motor terminals and at panel while pump is running If voltage at panel is 10 below the rated voltage on the motor nameplate consult your power company If the voltage at motor te...

Page 25: ...plate seal If water is leaking from the gap between the seal plate and pump housing then the seal plate and or seal plate O ring will need to be replaced Contact a qualified repair professional Exces...

Page 26: ...asket and clean out all debris trapped within Fill strainer side of pump housing with water and replace basket lid and locking ring Pump located above max prime height Measure the height from the pool...

Page 27: ...et with pump housing inlet port Fill the pump housing with water to the bottom edge of the inlet port Note If drain plug was removed replace before filling Clean the locking ring lid O ring and sealin...

Page 28: ...r screw clockwise to remove and set aside Insert a 3 8 slotted screwdriver into the hole on the fan end of the motor This will keep the motor shaft from rotating as you unthread the impeller from the...

Page 29: ...1 8 LG PAN HEAD PHILL 316SS QTY 2 15 O RING 341 EPDM O RING 341 EPDM 16 AP1017 DIFFUSER PUMP 17 AP1108 1 4 20 X 1 LG LEFT THD BUTTON SCREW 316 SS AND WASHER 5 OD X 23 ID X 1 THK EPDM RUBBER 18 O RING...

Page 30: ...9 AP1005 PUMP HOUSING 10 AP1040 IMPELLER ASSEMBLY 3 HP 11 AP1051 SEAL CERAMIC PS 3865R 12 AP1006 SEAL PLATE PUMP 13 AP1106 SCREW 1 4 20 X 7 8 LG HEX HEAD 18 8 SS AND WASHER 3 4 OD X 5 16 ID USS 18 8...

Page 31: ...urchase is not available the manufacturing date of the product will be the sole determination of the purchase date To obtain warranty service please contact the place of purchase AquaStar shall not be...

Reviews: