AquaStar Loxone Operation Manual Download Page 9

 

 

 

9

  

www.praherplastics.com

 

  Add the Device into the Loxone Config 

10

 
Before being able to use the Loxone Aquastar Air, it must be learnt-in. To do this the 
Aquastar needs to be in learing mode. 
 

10.1  Initial setup 

When the Loxone Aquastar Air is powered up for the first time, the learning mode will start 
automatically. 
 

10.2  Re-learning in process: 

To re-learn the Loxone Loxone Aquastar Air, simply press and hold the learn button for at 
least 5 seconds. The Loxone Loxone Aquastar Air is now back in the learning mode. 
 
The learn button is located on the Mainboard (red circled).  

Be aware that the antenna is screwed on the SMA connector (yellow circled). 

 

 

Once the unit is in the learning mode, the status LED flashes red-green-yellow in sequence. 
 
 

 

 

Summary of Contents for Loxone

Page 1: ...Zertifiziert nach certified acc to EN ISO 9001 2008 SMART HOME READY...

Page 2: ...8 Assembly 8 9 9 1 Function and installation diagram 8 Add the Device into the Loxone Config 9 10 10 1 Initial setup 9 10 2 Re learning in process 9 Electrical Connection 11 11 Technical data 12 12 C...

Page 3: ...3 www praherplastics com...

Page 4: ...amiliarization with the Loxone Aquastar Air and utilization of the same for the intended purpose This operation manual contains important information for safe proper and economical operation of the Lo...

Page 5: ...user s facility in the installation dismantling putting into operation operation or maintenance of the Loxone Aquastar Air must have read and understood the entire operation manual and in particular...

Page 6: ...ossible In this case the equipment is to be secured against unintentional start up and if necessary to be decommissioned Live parts can be uncovered when opening the cover or removing parts Before an...

Page 7: ...ficant technical products which are manufactured with high accuracy to the most modern technical production methods Entitled complaints will naturally be rectified as fast as possible if they occur Th...

Page 8: ...diagram 6 way valve type 11 2 und 2 Connections thread or solvent socket all connections open Max operating pressure ABS 11 2 2 3 5 bar GFK 11 2 2 6 bar Filtern der Fl ssigkeit z B Wasser Becken Pumpe...

Page 9: ...time the learning mode will start automatically 10 2 Re learning in process To re learn the Loxone Loxone Aquastar Air simply press and hold the learn button for at least 5 seconds The Loxone Loxone A...

Page 10: ...e and click on Create Device The device will now be listed in the Periphery tree The following objects are now available for configuration as part of the device itself Beyond the classic functions of...

Page 11: ...5A at cos 1 30VDC 5A Use a Auxiliary relay at greater loads The potential free relays Rel1 to Rel3 are designed as NO contacts and act as a functional enhancement in the Loxone system e Pressure senso...

Page 12: ...12 Voltage 100 240V AC 50 60 Hz Protection IP 65 Frequency 50 60 Hz Max Power 15 Watt 11 2 2 Connection diagram for pump and Praher ball valve EO510 13 13 1 Connection diagram for one phase pump 13 2...

Page 13: ...13 www praherplastics com Circuitboards 14 14 1 Mainboard 14 2 Power Supply...

Page 14: ...B 90 X 114 165 C 29 5 31 5 38 50 D 48 47 60 85 5 E 61 5 59 5 81 110 F 163 5 160 210 306 G 304 300 348 445 H 39 42 5 36 50 I 87 5 90 114 165 J 117 117 117 117 K 175 180 228 117 L 125 125 125 330 M 165...

Page 15: ...astar Air 16 1 Aquastar lid with foam rubber cord 2 Hexagon screw 3 Gear motor 4 Aquastar body bottom 5 Cabel with Connector plug for pressure sensor 6 V6ND valve 1 2 7 Control board 8 Pressure sensor...

Page 16: ...quastar Air 17 For dismantling the electronic drive off the valve a box spanner with a wrench size of 15mm is needed Carry out Installation in reverse order step 8 1 Inspection glas step 2 and hexagon...

Page 17: ...1 16 63 50 109 121 38 5 124 5 16 Check valve S6 D DN A Z t D PN 50 40 77 87 31 5 101 5 16 63 50 87 99 38 5 115 3 16 PVC S6 DN 32 40 50 d 40 50 63 G 1 1 4 1 1 2 2 A 77 77 87 D 101 5 101 5 115 3 E 138 5...

Page 18: ...ven at increased pressure The pump fails to switch on or off o Relay is burnt out The maximum pump current of 8A was exceeded o The pump is not properly connected The pump must always be looped via co...

Page 19: ...19 www praherplastics com Notizen Notes...

Page 20: ...Praher Plastics Austria GmbH BA DEEN 15 03 358 90454...

Reviews: