AquaStar Loxone Operation Manual Download Page 18

www.praherplastics.com 

18 

  Troubleshooting 

19

 
 

 

The drive rotates continually without approaching a position 

o

  Device was operated without a respective valve 

  Please return for repair; damage has already occurred in this case 

 

 

The drive continually triggers the backwash cycle 

o

  The system contains pressure boosting components (e.g., Solar absorbers) 

  Set the pressure sensor in such a way that the Loxone Aquastar Air does 

not trip even at increased pressure 

 

 

The pump fails to switch on or off 

o

  Relay is burnt-out 

  The maximum pump current of 8A was exceeded 

o

  The pump is not properly connected 

  The pump must always be looped via contacts 13-14 

 

 

The disk is not lifting freely, or the drive is not running smoothly, or flow noises 
can be heard  

o

  The pump does not switch off when the valve retainer is lifted 

  The pump must always be looped via contacts 13-14 

o

  The drop from the water surface to the valve is too great 

  Make sure that the total water column does not exceed 3m. 

o

  The V6 valve is soiled or clogged by debris 

  Clean the valve and use a pre-filter 

 
 
 
 
 
 

 

Summary of Contents for Loxone

Page 1: ...Zertifiziert nach certified acc to EN ISO 9001 2008 SMART HOME READY...

Page 2: ...8 Assembly 8 9 9 1 Function and installation diagram 8 Add the Device into the Loxone Config 9 10 10 1 Initial setup 9 10 2 Re learning in process 9 Electrical Connection 11 11 Technical data 12 12 C...

Page 3: ...3 www praherplastics com...

Page 4: ...amiliarization with the Loxone Aquastar Air and utilization of the same for the intended purpose This operation manual contains important information for safe proper and economical operation of the Lo...

Page 5: ...user s facility in the installation dismantling putting into operation operation or maintenance of the Loxone Aquastar Air must have read and understood the entire operation manual and in particular...

Page 6: ...ossible In this case the equipment is to be secured against unintentional start up and if necessary to be decommissioned Live parts can be uncovered when opening the cover or removing parts Before an...

Page 7: ...ficant technical products which are manufactured with high accuracy to the most modern technical production methods Entitled complaints will naturally be rectified as fast as possible if they occur Th...

Page 8: ...diagram 6 way valve type 11 2 und 2 Connections thread or solvent socket all connections open Max operating pressure ABS 11 2 2 3 5 bar GFK 11 2 2 6 bar Filtern der Fl ssigkeit z B Wasser Becken Pumpe...

Page 9: ...time the learning mode will start automatically 10 2 Re learning in process To re learn the Loxone Loxone Aquastar Air simply press and hold the learn button for at least 5 seconds The Loxone Loxone A...

Page 10: ...e and click on Create Device The device will now be listed in the Periphery tree The following objects are now available for configuration as part of the device itself Beyond the classic functions of...

Page 11: ...5A at cos 1 30VDC 5A Use a Auxiliary relay at greater loads The potential free relays Rel1 to Rel3 are designed as NO contacts and act as a functional enhancement in the Loxone system e Pressure senso...

Page 12: ...12 Voltage 100 240V AC 50 60 Hz Protection IP 65 Frequency 50 60 Hz Max Power 15 Watt 11 2 2 Connection diagram for pump and Praher ball valve EO510 13 13 1 Connection diagram for one phase pump 13 2...

Page 13: ...13 www praherplastics com Circuitboards 14 14 1 Mainboard 14 2 Power Supply...

Page 14: ...B 90 X 114 165 C 29 5 31 5 38 50 D 48 47 60 85 5 E 61 5 59 5 81 110 F 163 5 160 210 306 G 304 300 348 445 H 39 42 5 36 50 I 87 5 90 114 165 J 117 117 117 117 K 175 180 228 117 L 125 125 125 330 M 165...

Page 15: ...astar Air 16 1 Aquastar lid with foam rubber cord 2 Hexagon screw 3 Gear motor 4 Aquastar body bottom 5 Cabel with Connector plug for pressure sensor 6 V6ND valve 1 2 7 Control board 8 Pressure sensor...

Page 16: ...quastar Air 17 For dismantling the electronic drive off the valve a box spanner with a wrench size of 15mm is needed Carry out Installation in reverse order step 8 1 Inspection glas step 2 and hexagon...

Page 17: ...1 16 63 50 109 121 38 5 124 5 16 Check valve S6 D DN A Z t D PN 50 40 77 87 31 5 101 5 16 63 50 87 99 38 5 115 3 16 PVC S6 DN 32 40 50 d 40 50 63 G 1 1 4 1 1 2 2 A 77 77 87 D 101 5 101 5 115 3 E 138 5...

Page 18: ...ven at increased pressure The pump fails to switch on or off o Relay is burnt out The maximum pump current of 8A was exceeded o The pump is not properly connected The pump must always be looped via co...

Page 19: ...19 www praherplastics com Notizen Notes...

Page 20: ...Praher Plastics Austria GmbH BA DEEN 15 03 358 90454...