Troubleshooting
19
The drive rotates continually without approaching a position
o
Device was operated without a respective valve
Please return for repair; damage has already occurred in this case
The drive continually triggers the backwash cycle
o
The system contains pressure boosting components (e.g., Solar absorbers)
Set the pressure sensor in such a way that the Loxone Aquastar Air does
not trip even at increased pressure
The pump fails to switch on or off
o
Relay is burnt-out
The maximum pump current of 8A was exceeded
o
The pump is not properly connected
The pump must always be looped via contacts 13-14
The disk is not lifting freely, or the drive is not running smoothly, or flow noises
can be heard
o
The pump does not switch off when the valve retainer is lifted
The pump must always be looped via contacts 13-14
o
The drop from the water surface to the valve is too great
Make sure that the total water column does not exceed 3m.
o
The V6 valve is soiled or clogged by debris
Clean the valve and use a pre-filter