5
4
5) Troubleshooting
5.1
Reduced Flow
• Check pump and impeller for any blockages. It may be necessary to take the impeller and
cage out and clean them.
• Check pipe and plumbing for any kinks or blockages.
5.2 Pump is not pumping:
• Make sure nothing is blocking the impeller. It may be necessary to clean pump.
6) SAFeTY CONSIderATIONS
• This product must be installed on an electrical circuit protected by a Ground Fault Circuit
Interrupter (GFCI). Refer to your electric supply dealer for details.
• If you have any questions or doubts about this product, consult a qualified electrician.
• Do not lift the pump by the power cord — it is not designed for portable use.
• Always disconnect from electrical supply before attempting to service or perform
maintenance procedures.
7) rePLACemeNT PArTS
To order replacement parts or accessories, contact your local Aquascape
™
retailer.
Scala/Scale
1:2
223
8,781
12
8
5,
05
6
11
1
4,
38
0
CAGE
BASE
CAGE NOSE
VOLUTE
O-RING
IMPELLER
REAR BEARING
1:2
Scala/Scale
1:2
158
6,224
91 3,
58
3
79 3,
12
7
CAGE
BASE
CAGE NOSE
IMPELLER
VOLUTE
O-RING
Scala/Scale
1:2
223
8,781
12
8
5,
05
6
11
1
4,
38
0
CAGE
BASE
CAGE NOSE
VOLUTE
O-RING
IMPELLER
REAR BEARING
1:2
Scala/Scale
1:2
158
6,224
91 3,
58
3
79 3,
12
7
CAGE
BASE
CAGE NOSE
IMPELLER
VOLUTE
O-RING
Figure 2
Figure 3
Pumps 750 GPH, 1000
GPH, and 1500 GPH
Pumps 350 GPH and 500 GPH
Replacement Part
item #
Replacement Part
item#
350 gph Impeller
98491
350 gph - 500 gph Cage
98582
500 gph Impeller
98492
750 gph - 2000 gph Cage
98584
750 gph Impeller
98493
350 gph - 500 gph Base
98570
1000 gph Impeller
98494
750 gph - 1500 gph Base
98572
1500 gph Impeller
98495
2000 gph Base
98575
2000 gph Impeller
98496
optional accessories
item #
Divert Valve
20000
Maxi Waterbell Fountain Head
21000
Maxi Waterlily Fountain Head
22000
Foam Jet Fountain Head
23000
Maxi Daisy Fountain Head
24000
Fitting Threaded Adapter 350 gph - 500 gph
99530
Fitting Threaded Adapter 750 gph - 2000 gph
99531