![AquaScape Ultra 1100 Instructions & Maintenance Download Page 3](http://html1.mh-extra.com/html/aquascape/ultra-1100/ultra-1100_instructions-and-maintenance_2960914003.webp)
No.
Description
1.
(1) Ultra
TM
Water Pump
2.
(1) ½” Valve
3.
(1) ¾”, 1”, 1¼” Multi-Hose
Adapter
4.
(1) FPT 90
0
Elbow ½”
5.
(1) MPT Coupling ½”
Contents 400/550/800
No.
Description
1.
(1) Ultra
TM
Water Pump
2.
¾” 3-Way Valve
3.
(1) 1”, 1¼”, 1½” Multi-Hose
Adapter
4.
(1) ¾”, 1”, 1¼” Multi-Hose
Adapter
5.
(1) FPT 90
0
Elbow ¾”
6.
(1) MPT Coupling ¾”
Contents 1100/1500/2000
1
2
3
4 5
1
2
3 4
5
6
WARNING
Symbol - Will alert you to the
possibility of damage or injury if you do not
comply with the warnings that accompany them.
The hazard may come from something
mechanical or from electrical shock.
Helpful Symbols
TIP
symbol - Helpful information provided by a
professional pond installer.
3
aquascapeinc.com |
☎
CAN 1-866-766-3426 |
☎
US 1-866-877-6637
Contents
Optional Accessories
Ultra
™
Pump Fountain Head Kits
Incorporate a fountain into your pond by adding an Ultra
TM
Pump Fountain Head Kit to your
Ultra
TM
Water Pump. Each kit comes complete with three fountain head options: Waterbell,
Foaming Jet and Daisy. Each kit also includes four 3.5" extensions for customizable fountain
height and an integrated diverter valve that allows you to easily divert water to an external
fi lter, ornamental spitter or waterfall.
Item #91045 is compatible with 400/550/800 Water Pumps.
Item # 91046 is compatible with 1100/1500/2000 Water Pumps.
Ultra
™
400/550/800
Ultra
™
1100/1500/2000
Safety Information
WARNING:
Risk of electric shock – This pump
has not been approved for use in swimming
pool or marine areas.
WARNING:
To provide continued protection
against risk of electric shock, connect to
properly grounded, ground fault circuit
interrupter (GFCI) outlets only, using the
following guidelines:
(A) Have a qualifi ed electrician install a properly
grounded receptacle outlet, acceptable for outdoor
use and protected from snow and rain.
(B) Inspect cord before using.
(C) Do not use extension cords.
(D) Any wiring of pumps should be performed by a
qualifi ed electrician to ensure code compliance
and user safety.
(E) Unplug pump at receptacle outlet when not
in use or before removal from pond.
(F) To reduce risk of electrical shock, all wiring
and junction connections should be made per local
codes. Requirements may vary depending on usage
and location.
(G) The power cable should be protected at all times to
avoid punctures, cuts, bruises and abrasions.
(H) Never handle power cords with wet hands.
(I) Do not remove cord and strain relief. Do not
connect conduit to pump.
(J) Do not use power cable to lift pump.
Item #91045
Item #91046