AquaScape Ultra 1100 Instructions & Maintenance Download Page 11

11

aquascapeinc.com | 

☎ 

CAN 1-866-766-3426 | 

☎ 

US 1-866-877-6637

No.

Description

1.

(1) Ultra

TM

 Water Pump

2.

(1) MPT Coupling ½”

3.

(1) FPT 90

0

 Elbow ½”

4.

(1) ½” x ½” Barb Valve

5.

(1)  ½” Multi-Hose Adapter 

x ¾”, 1”, 1¼”

Contents 400/550/800

No.

Description

1.

(1) Ultra

TM

 pompe à eau

2.

(1)  ¾” Adaptateur multi-tuyau 

x ¾”, 1”, 1¼” 

3.

(1)  ¾” Adaptateur multi-tuyau 

1”, 1¼”, 1½”

4.

(1) FPT 90

0

 Coude ½”

5.

(1) MPT Couplage ½”

6.

¾” Vanne 3 voies 

Contents 1100/1500/2000

Symbole AVERTISSEMENT

 -  Vous alertera sur 

la possibilité de dommages corporels ou matériels si 

vous ne vous conformez pas aux avertissements qui 

les accompagnent. Le danger peut avoir une origine 

mécanique ou être dû à une électrocution.

Symboles utiles

Symbole CONSEIL

 -  Informations utiles fournies 

par un installateur professionnel de bassins.

Contents

Accessoires en option

Jeux de têtes de fontaine pour pompe UltraMC

Intégrez une fontaine à votre bassin en ajoutant à votre pompe UltraMC un jeu de têtes de fontaine 

pour pompe UltraMC. Chaque jeu est complet et offre trois options de tête de fontaine : Cloche 

d'eau, Jet moussant et Marguerite. Chaque jeu contient également quatre rallonges de 3,5 po pour 

une hauteur de fontaine sur mesure et une vanne de répartition qui vous permet de détourner l'eau 

vers un fi ltre externe, une gargouille décorative ou une chute d'eau.
Article # 91045 est compatible avec les pompes à eau 400/550/800. 

Article # 91046 est compatible avec les pompes à eau 1100/1500/2000.

Informations sur la sécurité

MISE EN GARDE :

 risque de choc électrique – 

Cette pompe n’a pas été approuvée pour une 
utilisation en piscine ou en zones marines.

MISE EN GARDE :

 Afi n d’assurer une protection 

continue contre le risque de décharge 
électrique, ne branchez le cordon qu’à une 
prise d’alimentation avec mise à la terre, en 
observant les directives suivantes :

(A)   Faites installer une prise de courant correctement 

mise à la terre convenant à une utilisation extérieure 

et protégée de la neige et de la pluie

(B)  Inspectez le cordon d’alimentation avant l’utilisation
(C)   N’utilisez pas de rallonge électrique 
(D)    Tout câblage relié à la pompe devrait être exécuté 

par un électricien qualifi é pour être en conformité 

avec les normes et s’assurer de la sécurité de 

l’utilisateur 

(E)   Débranchez la pompe de la prise de courant lorsque 

vous ne vous en servez pas ou avant de la sortir du 

plan d’eau

(F)   Pour réduire le risque de décharge électrique, 

tout le câblage et les raccordements de jonction 

devraient être exécutés selon les normes locales. Les 

exigences peuvent varier en fonction de l’utilisation et 

de l’emplacement 

(G)   Le câble électrique devrait être protégé en tout 

temps pour éviter les perforations, les coupures, les 

ecchymoses et les abrasions 

(H)    Ne manipulez jamais les cordons d’alimentation avec 

les mains humides 

(I)   N’enlevez pas le cordon et le dispositif de réduction 

de la tension. Ne joignez pas le conduit à la pompe 

(J)    Ne soulevez pas la pompe par le cordon 

d’alimentation.

1

2

3

4 5

1

2

3 4

5

6

Ultra

 400/550/800

Ultra

 1100/1500/2000

Article

 #91045

Article

 #91046

Summary of Contents for Ultra 1100

Page 1: ...tem 91009 2000 Item 91010 Available in flow rates from 400 to 2000 GPH I N S T R U C T I O N S M A I N T E N A N C E Ultra 400 550 800 1100 Ultra 1500 2000 3 Y EAR WARRA N T Y G A R ANTIE DE 3 A N S AN AN A 3 3 3 1500 2000 3 3 Y E Y E Y A AR R WA WA W RR R R RA A A A N N T T N T N Y T Y T G G G A G N S S A 3 3 3 3 3 Ultra 1500 2000 AR W WA A WA W WA W RR RA A ...

Page 2: ... and water features These all in one kits include a single or three way flow control valve multi hose adapter s and a threaded 900 elbow connection making it adaptable to almost any hose or application Ultra Water Pumps are ideal for supplying water to run fountains water features external filters and spitting ornaments The combination of energy efficient mag drive performance flow and ease of mai...

Page 3: ...namental spitter or waterfall Item 91045 is compatible with 400 550 800 Water Pumps Item 91046 is compatible with 1100 1500 2000 Water Pumps Ultra 400 550 800 Ultra 1100 1500 2000 Safety Information WARNING Risk of electric shock This pump has not been approved for use in swimming pool or marine areas WARNING To provide continued protection against risk of electric shock connect to properly ground...

Page 4: ...hazardous materials or liquids other than water such as oil or organic solvents Do not block or restrict discharge Products returned must be cleaned sanitized or decontaminated as necessary prior to shipment to ensure that employees will not be exposed to health hazards in handling said material All applicable laws and regulations shall apply IMPORTANT Aquascape Inc is not responsible for losses i...

Page 5: ...o the pump The collared connections allow the pump to be quickly and easily disconnected from the tubing for pump removal or maintenance Attach the tubing to the selected fitting s using a twisting motion If the tubing fits loosely a hose clamp not included can be used to secure the attachment In some instances the tubing may be difficult to attach to the selected fitting If this is the case we re...

Page 6: ...entering bushings that center the ceramic impeller shaft on both ends Connect the pump to an outlet that is protected by a ground fault circuit interrupter GFCI Once the pump is running and water is circulating check for leaks where the external connections are made Operation and Maintenance Filter Screens The outer screen is designed to pop off when it is gently pulled from either side Do not rem...

Page 7: ... required on both ends of the impeller shaft one bushing is located inside the pump and an outer bushing sits in the water chamber cover 3 Slide the first interior bearing washer onto the ceramic shaft 4 Place the ceramic impeller shaft into the pump checking to be sure the centering bushing seats inside the pump 5 Carefully slide the impeller back onto the shaft Use caution the impeller assembly ...

Page 8: ...r GFCI may have tripped The pump is not receiving the correct voltage VIDEO ON ULTRATM WATER PUMP MAINTENANCE TROUBLESHOOTING TIPS Pump Model Filter Sponge Impeller Kit Front Cover Kit Discharge Fittings Kit 400 91033 4 pkg 91039 91050 91055 550 91034 4 pkg 91040 91051 91055 800 91035 4 pkg 91041 91051 91055 1100 91036 2 pkg 91042 91052 91057 1500 91037 2 pkg 91043 91053 91057 2000 91038 2 pkg 910...

Page 9: ... N N T T N T N Y T Y T G G G A G N S S A 3 3 3 3 3 Ultra 1500 2000 AR W WA A WA W WA W RR RA A Pompe submersible pour fontaine cascades et filtre Pour les modèles suivants 400 article no 91005 550 article no 91006 800 article no 91007 1100 article no 91008 1500 article no 91009 2000 article no 91010 Disponible en débits de 1514 à 7570 L h I N S T R U C T I O N S E T E N T R E T I E N ...

Page 10: ...ne vanne directionnelle à trois voies et un raccord de tuyau à tailles multiples le rendant adaptable à presque n importe quel tuyau ou taille de tube Les pompes Ultra sont idéales pour fournir de l eau aux fontaines aux aménagements aquatiques aux filtres externes et aux ornements cracheurs d eau La combinaison d un excellent rendement en efficacité énergétique du maintien de niveau d eau élevé e...

Page 11: ... 2000 Informations sur la sécurité MISE EN GARDE risque de choc électrique Cette pompe n a pas été approuvée pour une utilisation en piscine ou en zones marines MISE EN GARDE Afin d assurer une protection continue contre le risque de décharge électrique ne branchez le cordon qu à une prise d alimentation avec mise à la terre en observant les directives suivantes A Faites installer une prise de cou...

Page 12: ...sées pour relever la pompe et éviter de la faire reposer sur le fond de la pièce d eau Montré avec Pond Filter Urn 77006 or 77011 ump w AquaBasin Application 12 US 1 866 877 6637 CAN 1 866 766 3426 aquascapeinc com Mode d emploi La pompe doit toujours être submergée lors de son utilisation sinon elle pourrait surchauffer entraînant ainsi sa défaillance et annulant de ce fait la garantie NE FAITES ...

Page 13: ...e permettent de débrancher rapidement et facilement la tuyauterie de la pompe pour la retirer ou l entretenir Branchez le tuyau sur le ou les raccords choisis en le tordant Si le tuyau n est pas bien serré vous pouvez utiliser un collier de serrage non inclus pour que le tuyau soit solidement attaché Dans certains cas le tuyau peut être difficile à attacher au raccord choisi Si c est le cas nous r...

Page 14: ...t protégée par un disjoncteur différentiel de fuite à la terre Une fois que la pompe tourne et que l eau circule à travers le s filtre s ou les chutes d eau inspectez tous les raccords et toutes les chutes d eau pour vérifier qu il n y a aucune fuite au niveau des branchements externes Operation and Maintenance Cage de pompe N enlevez ni la cage supérieure ni la cage inférieure ni l éponge de la p...

Page 15: ...l intérieur de la pompe et une bague externe reposant dans le couvercle de la chambre d équilibre 3 Faites glisser la rondelle de la bague intérieure sur l arbre en céramique 4 Placez l arbre en céramique du rotor dans la pompe en veillant à ce que la bague de centrage repose bien à l intérieur de la pompe 3 2 5 7 8 4 6 8 Replacez l éponge du préfiltre et la crépine sur le corps de pompe par simpl...

Page 16: ...la pompe Assurez vous que rien ne bloque ou n est enveloppé autour de la turbine Assurez vous que la pompe reçoit la bonne tension Pompe en panne L interrupteur du disjoncteur de fuite à la terre GFCI peut avoir été déclenché La pompe ne reçoit pas la bonne tension 4 Ultra 400 550 800 Ultra 1100 1500 2000 Pump Model Front Cover Kit Filter Sponge Impeller Kit Discharge Fittings Kit 400 91050 91033 ...

Reviews: