5
Prepare Rhino Tank
Wrap your pipe nipples with NSF certified
plumber's tape. Connect the nipples to the
system's inlet and outlet.
UV System Preparation
This set up requires the installation of a UV system. Before continuing,
stop now and read the separate, included UV manual in its entirety.
NOTE: DO NOT use pipe solvent (dope),
as solvents in some types of pipe dope
may cause damage to plastic fittings. Do
not over-tighten to prevent damage to
filter head.
4
3
INSTALLATION STEPS
WARNING
Never look directly at a lighted UV lamp. Ultraviolet rays can be harmful to eyes.
Assembly is required before installation. Internal components are fragile.
When installing on metallic plumbing, ensure you take the following
precautions. Securely install two (2) grounding clamps and a #4 copper
wire (not included) across the location where the system will be installed.
Tightly clamp at both ends, as shown in the illustration.
Ground
Clamp
Ground
Clamp
Ground Wire
WARNING
ELECTRICAL SHOCK HAZARD
Prior to installation on metallic plumbing, securely install two grounding clamps and a #4 copper wire
per installation instructions. Failure to follow these instructions can result in death or electric shock.
5
COPPER PIPES ONLY (proceed to Step 6 for PVC Pipes)