Organic chemicals included by surrogate testing
VOCs
(by surrogate testing using
chloroform)
Drinking water
regulatory level
(MCL/MAC) mg/L
Influent/
Unfiltered
Effluent/
Filtered
Percent
Reduction
alachlor
0.002
0.050
0.001
>98%
atrazine
0.003
0.100
0.003
>97%
benzene
0.005
0.081
0.001
>99%
carbofuran
0.04
0.190
0.001
>99%
carbon tetrachloride
0.005
0.078
0.0018
98%
chlorobenzene
0.1
0.077
0.001
>99%
chloropicrin
—
0.015
0.0002
99%
2,4-D
0.07
0.110
0.0017
98%
dibromochloropropane
(DBCP)
0.0002
0.052
0.00002
>99%
o-dichlorobenzene
0.6
0.080
0.001
>99%
p-dichlorobenzene
0.075
0.040
0.001
>98%
1,2-dichloroethane
0.005
0.088
0.0048
95%
1,1-dichloroethylene
0.007
0.083
0.001
>99%
cis-1,2-dichloroethylene
0.07
0.170
0.0005
>99%
trans-1,2-dichloroethylene
0.1
0.086
0.001
>99%
1,2-dichloropropane
0.005
0.080
0.001
>99%
cis-1,3-dichloropropylene
—
0.079
0.001
>99%
dinoseb
0.007
0.170
0.0002
99%
endrin
0.002
0.053
0.00059
99%
ethylbenzene
0.7
0.088
0.001
>99%
ethylene dibromide (EDB)
0.00005
0.044
0.00002
>99%
haloacetonitriles (HAN)
Bromochloroacetontrile
—
0.022
0.0005
98%
Dibromoacetontrile
—
0.024
0.0006
98%
Dichloroacetontrile
—
0.0096
0.0002
98%
Trichloroacetontrile
—
0.015
0.0003
98%
haloketones (HK)
1,1-dichloro-2-propanone
—
0.0072
0.0001
99%
1,1,1-trichloro-2-propanone
—
0.0082
0.0003
96%
heptachlor (H-34, Heptox)
0.0004
0.025
0.00001
>99%
heptachlor epoxide
0.0002
0.0107
0.0002
98%
hexachlorobutadiene
—
0.044
0.001
>98%
hexachlorocyclopentadiene 0.05
0.060
0.000002 >99%
lindane
0.0002
0.055
0.00001
>99%
methoxychlor
0.04
0.050
0.0001
>99%
pentachlorophenol
0.001
0.096
0.001
>99%
simazine
0.004
0.120
0.004
>97%
styrene
0.1
0.150
0.0005
>99%
1,1,2,2-tetrachloroethane
—
0.081
0.001
>99%
tetrachloroethylene
0.005
0.081
0.001
>99%
toluene
1
0.078
0.001
>99%
2,4,5-TP (silvex)
0.05
0.270
0.0016
99%
tribromoacetic acid
—
0.042
0.001
>98%
1,2,4-trichlorobenzene
0.07
0.160
0.0005
>99%
1,1,1-trichloroethane
0.2
0.084
0.0046
95%
1,1,2-trichloroethane
0.005
0.150
0.0005
>99%
trichloroethylene
0.005
0.180
0.0010
>99%
Trihalomethanes (THMs)
Influent/
Unfiltered
Effluent/
Filtered
Percent
Reduction
Bromodichloromethane
(THM)
0.080
0.300
0.015
95%
Bromoform (THM)
Chloroform (THM)
Chlorodibromomethane
(THM)
Xylenes (total)
10
0.070
0.001
>99%
Testing Performed under NSF/ANSI Standards 42 and 53 and in accordance with the California Department of Health Services Drinking Water Treatment Device Program.
This system has been tested according to NSF/ANSI 42, 53, 58, 401 & P473 for reduction of the substances listed below. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53, 58, 401 & P473.
Do not use with water that is microbiologically
unsafe or of unknown water quality without adequate
disinfection before or after the system.
NSF/ANSI 42
Minimum
reduction
Overall %
reduction
Results
Chlorine Reduction, Free Available
<0.5 mg/l
97.66%
Pass
Chloramine Reduction, Free Available
<0.5 mg/l
97.66%
Pass
Particulate Reduction
85%
99.9%
Pass
NSF/ANSI 53
Required
reduction
Overall %
reduction
Results
Cyst Live Cryptosporidium & Giardia
99.95%
>99.99%
Pass
Mercury Reduction pH 8.5
<2 ug/L
>95.8%
Pass
Mercury Reduction pH 6.5
<2 ug/L
>96.5%
Pass
Lead Reduction pH 6.5
<10 ug/L
>99.4%
Pass
Lead Reduction pH 8.5
<10 ug/L
>99.3%
Pass
MTBE Reduction
<5 ug/L
86.6%
Pass
Turbidity
<0.5 NTU
99.1%
Pass
VOC Surrogate Test
95%
99.4%
Pass
Asbestos Reduction
99%
>99%
Pass
NSF/ANSI 58
Maximum
Concentration
Minimum
Reduction
Overall %
Reduction
Results
Arsenic Pentavalent
0.30
mg
/
L
±10%
80.0%
97.6%
Pass
Barium
10.0
mg
/
L
±10%
80.0%
95.2%
Pass
Cadmium
0.30
mg
/
L
±10%
83.3%
95.3%
Pass
Chromium Hexavalent
0.30
mg
/
L
±10%
66.7%
97.0%
Pass
Chromium Trivalent
0.30
mg
/
L
±10%
66.7%
96.6%
Pass
Copper
0.30
mg
/
L
±10%
56.7%
96.6%
Pass
Fluoride
8.0
mg
/
L
±10%
81.2%
95.7%
Pass
Lead
0.15
mg
/
L
±10%
93.3%
96.6%
Pass
Nitrate/Nitrite
30.0
mg
/
L
±10%
66.70%
82.40%
Pass
Radium 226/228
25
pCi
/
L
±10%
80.0%
80.0%
Pass
Selenium
0.10
mg
/
L
±10%
50.0%
97.9%
Pass
TDS
750
mg
/
L
±10%
75.0%
95.0%
Pass
Turbidity
11 ± NTU
95.4%
99.1%
Pass
NSF/ANSI 401
Maximum
Concentration
Minimum
Reduction
Overall %
Reduction
Results
Atenolol
30 ng/L
94.2%
94.2%
Pass
Bisphenol A
300 ng/L
98.80%
98.9%
Pass
Carbamazepine
200 ng/L
98.6%
98.6%
Pass
DEET
200 ng/L
98.7%
98.7%
Pass
Estrone
20 ng/L
96.30%
96.5%
Pass
Ibuprofen
60 ng/L
95.3%
95.4%
Pass
Linuron
20 ng/L
96.6%
96.6%
Pass
Meprobamate
60 ng/L
94.7%
94.7%
Pass
Metolachlor
200 ng/L
98.6%
98.6%
Pass
Naproxen
20 ng/L
96.3%
96.4%
Pass
Nonyl phenol
200 ng/L
97.50%
97.5%
Pass
Phenytoin
30 ng/L
95.50%
95.6%
Pass
TCEP
700 ng/L
98%
98%
Pass
TCPP
700 ng/L
97.8%
97.8%
Pass
Trimethoprim
20 ng/L
96.7%
96.7%
Pass
NSF P473
Influent
challenge
concentration
Maximum
permissible
product water
concentration
Overall %
reduction
Results
Perfluorooctanoic acid (PFOA) &
Perfluorooctane sulfonate (PFOS)
1.5 ±10% ug/L 0.07 ug/L
96%
Pass
The AQ-RO3 has been tested and certified by NSF
International against NSF/ANSI Standards 42, 53
and 401 in model AQ-RO-3 for the reduction claims
specified on the Performance Data Sheet as verified
and substantiated by test data and at nsf.org.
The AQ-RO-3 has been tested and certified by
NSF International against NSF/ANSI Standard
58 for the reduction claims specified on the
Performance Data Sheet as verified and
substantiated by test data and at nsf.org.
AQ-RO-3_PDS_20171106
Performance Data for the OptimH2O™ Drinking Water System: Model AQ-RO-3
Replacement
Operating
pressure range
Operating
temp range
Recovery
Rating
Efficiency
Rating
Daily Produc-
tion (DPR)
AQ-RO3-RO, AQ-RO3-Carbon,
AQ-RO3-Claryum
40-100 psi
275-689 kPa
40-90° F
4.44-32.2° C
29.43%
17.91%
13.32 gallons
50.4 liters
Manufactured by: Aquasana, Inc.
6310 Midway Road · Haltom City, Texas 76117 · 866.662.6885