Do not use with water that is microbiologically unsafe or of unknown water quality without 

adequate disinfection before or after the system. Systems certified for cyst reduction may be 

used on disinfected waters that may contain filterable cysts.

Care and Maintenance

To clean your filter unit, wipe down the exterior with a damp cloth. 

For the AQ-5200 and AQ-5300 only: 

Once filters are at 95% capacity (about every 6 months), the battery alarm will sound and flash red 
when water is flowing and will continue for 15 seconds once water is turned off. Change the battery 
every time you replace your filters. The battery is included with the filter replacement cartridges.

Pure Satisfaction

All Aquasana products offer a 90-day 100% satisfaction guarantee. (A 1-year 
warranty is included, which covers defects in materials and workmanship.) If for 
any reason you are not satisfied with your purchase, simply call us or the dealer you 
purchased from. A Return Authorization Code and a full refund will be promptly 
issued upon return. Thank you for choosing Aquasana!

This filter system is designed and tested for use with genuine Aquasana parts, including 
replacement filters, faucet and all hardware. Use of parts from other manufacturers may result in 
loss of contaminant reduction performance, system damage or failure. Use of parts from other 
manufacturers will also void your warranty. Please visit www.aquasana.com for all replacement 
parts.

For conditions of use, health claims certified by the California Department of Public Health, and 
replacement parts see product data sheet. 

California Department of Public Health Certification Number 13-2173.

Precautions:

•   Filter is only to be used with cold water.

•   If you experience a leak at the hose connection, disconnect and re-seat the hose.

•  Installation must comply with local laws.

•   Aquasana is not liable for consequential or incidental damages due to  improper installation. 

AQ-5100

Replacement cartridge: 
AQ-5100R

Rated service flow: 
0.5 gpm

Max capacity: 
200 gal

Min working pressure: 
20 psi  (1.40 kg/cm

2

)

Max working pressure: 
80 psi (5.62 kg/cm

2

)

Min operating temperature: 
40° F (4.44° C)

Max operating temperature: 
90° F (32.22° C)

AQ-5200

Replacement cartridge: 
AQ-5200R

Rated service flow: 
0.5 gpm

Max capacity: 
500 gal

Min working pressure: 
20 psi  (1.40 kg/cm

2

)

Max working pressure: 
80 psi (5.62 kg/cm

2

)

Min operating temperature: 
40° F (4.44° C)

Max operating temperature: 
90° F (32.22° C)

AQ-5300

Replacement cartridge: 
AQ-5300R

Rated service flow: 
0.5 gpm

Max capacity: 
600 gal

Min working pressure: 
20 psi  (1.40 kg/cm

2

)

Max working pressure: 
80 psi (5.62 kg/cm

2

)

Min operating temperature: 
40° F (4.44° C)

Max operating temperature: 
90° F (32.22° C)

WARNING

Do not use tools to remove 
or tighten sumps. Over 
tightening can cause 
damage and result in 
leaking. Hand tighten only.

Remove each 

sump from  

the manifold  

by hand.

Place  

wrench  

over sump  

top and slide down.

Continue turning 

counterclockwise.

Remove top  

and filter.

Summary of Contents for AQ-5100

Page 1: ...CounterWaterFilter Single Stage 5100 Two Stage 5200 and Three Stage 5300 systems Welcome to the Aquasana experience You are about to enjoy clean healthy water and the peace of mind that comes from knowing award winning filter technology is working for you ...

Page 2: ...aucet Washer 1 H Faucet Nut 1 I 3 x1 4 Poly tubing 1 J Chrome nut 1 K Plastic collar 2 L Plastic tube insert 1 M 3 x1 4 Poly tubing 1 N Brass nut 1 O Brass tube insert 1 P 1 4 Brass Tee 1 A AQ 5100 filter unit B Faucet 1 C Filter Cartridge 1 D Screws with anchors 2 E Faucet Rubber Washer 1 F Faucet Spacer 1 G Faucet Washer 1 H Faucet Nut 1 I 3 x1 4 Poly tubing 1 J Chrome nut 1 K Plastic collar 2 L...

Page 3: ... compress the plastic sleeve and create a seal NOTE Use a wrench to ensure complete seal Avoid over tightening 9 Connect supply lines insert tubing from the tee fitting into the inlet side and insert tubing from the faucet into the outlet side Use diagram on the right to mark tubing depth to ensure they get inserted completely It is VERY IMPORTANT to insert tubing completely so leaking does not oc...

Page 4: ...void your warranty Please visit www aquasana com for all replacement parts For conditions of use health claims certified by the California Department of Public Health and replacement parts see product data sheet California Department of Public Health Certification Number 13 2173 Precautions Filter is only to be used with cold water If you experience a leak at the hose connection disconnect and re ...

Page 5: ...6 6 96 6 Pass Meprobamate 60 ng L 94 7 94 7 Pass Metolachlor 200 ng L 98 6 98 6 Pass Naproxen 20 ng L 96 3 96 4 Pass Nonyl phenol 200 ng L 97 50 97 5 Pass Phenytoin 30 ng L 95 50 95 6 Pass TCEP 700 ng L 98 98 Pass TCPP 700 ng L 97 8 97 8 Pass Trimethoprim 20 ng L 96 7 96 7 Pass NSF P473 Influent challenge concentration Maximum permissible product water concentration Overall reduction Results Perfl...

Page 6: ...0 0 000002 99 lindane 0 0002 0 055 0 00001 99 methoxychlor 0 04 0 050 0 0001 99 pentachlorophenol 0 001 0 096 0 001 99 simazine 0 004 0 120 0 004 97 styrene 0 1 0 150 0 0005 99 1 1 2 2 tetrachloroethane 0 081 0 001 99 tetrachloroethylene 0 005 0 081 0 001 99 toluene 1 0 078 0 001 99 2 4 5 TP silvex 0 05 0 270 0 0016 99 tribromoacetic acid 0 042 0 001 98 1 2 4 trichlorobenzene 0 07 0 160 0 0005 99 ...

Page 7: ...aquasana com For exclusive deals facebook com aquasana twitter com aquasana System tested and certified by NSF International against NSF ANSI Standard 42 53 401 and conforms to NSF protocol P473 for reduction of claims specified on the Performance Data Sheet and at nsf org aq5x00_install_20171106 ...

Reviews: