13
f. Running status checking
1) Press”
” for 5 seconds, a sound of “di” can be heard and it will enter into running status checking”
2) at this time, the display alternately shows status point
“C0” and its corresponding value.
3) Change status pointer through”
” and “
”, the corresponding value also changes with it.
4) Press “
” can quit “running status checking” mode
5) Running status checking table
Symbol
Content
Unit
C0
Inlet water temp
℃
C1
Outlet water temp
℃
C2
Ambient temp
℃
C3
Exhaust temp
℃
C4
Outer coil pipe temp
℃
C5
Gas return temp
℃
C6
Inner coil pipe tem
℃
C9
Radiator temp
℃
C10
Electronic expansion valve opening
P
g. WIFI (Optional)
First, download the InverGo app from the Android Playstore or Apple Appstore. Then create an account
using email address identification.
When the screen is on, press“
”for 3 seconds, after “
” flashing, enter WIFI connection.
Connect Wifi on mobile phone and input password, then control equipment by Wifi, When APP connects
WIFI successfully
,
“
” lights on.
Clear Wifi setting history: When screen is on, press"
" for 10 seconds, after "
" flashing for 10
seconds,
lights off.
h. Smartphone application
The InverGo app allows you to control the temperature of your remote pool. You can also check error
codes and schedule different operating hours.
After the swimming pool heater start up, please kindly checking for any abnormal noise from the
machine.
Summary of Contents for BLACK SILENCE
Page 1: ...BLACK SILENCE INVERTER POOL HEAT PUMP EN FR EN USER S MANUAL ...
Page 20: ...18 I Appendix ...
Page 21: ...19 ...
Page 22: ...20 ...
Page 25: ...23 ...
Page 26: ...24 ...
Page 28: ......
Page 29: ...BLACK SILENCE Pompe à chaleur Inverter pour piscine EN FR EN Le manuel de fonctionnement ...
Page 53: ...23 2 Appuyez sur ajouter appareil et suivez ensuite les instructions d appairage ...
Page 54: ...24 ...
Page 56: ...AQ06MC R32 02 ...