background image

1

PREFACE

Details of this Manual

This manual contains the installation and operation instructions for the Aquarii Zino (pronounced: Zee-No) to be performed by a 
qualified and trained installer. The Mounting Option detailed in this manual is:

• Slope Recessed Mount

Be sure to read this entire manual before beginning the installation procedures. DO NOT DISCARD THIS MANUAL.

Questions about this Manual?

The present material is subject to change without notice. If you have any questions or concerns regarding your Aquarii Product 
you can contact us at:

Aquarii Inc
17 Genesee Street
Camillus, NY, 13031
315-672-8807
[email protected]
aquariitech.com

CLEANING AND MAINTENANCE

All Cleaning and Maintenance procedures must be performed by a qualified individual (Electrician/Technician) or Aquarii 
Personnel. The following precautions and actions must be taken to ensure personal and product safety during all Cleaning and 
Maintenance Procedures:

• The sites power supply is disconnected/shut-off
• Wear the required Protective Eye Wear
• DO NOT TOUCH the LED Array or Optical Lenses
• The fixture is not altered or does not receive any non-authorized services. Doing so will void the Aquarii Warranty.

Fixture Safety Warnings

The following MUST BE read and adhered to before beginning any installation or mounting procedures.

• Do not connect the fixture to an electrical system that does not provide grounding equipment.
• Do not connect the fixture to a power source with a Voltage/AC level outside the fixture parameters.
• The fixture cannot be hung with supply wires or wire connectors.
• Wiring MUST NOT come into contact with any surfaces that have sharp edges to ensure personal/product safety.
• The fixture power supply MUST BE disconnected from the sites power input until instructed otherwise.
• All installation procedures must be performed by a properly trained/certified electrician.

AQUARII WARRANTY

This limited warranty is provided by Aquarii, Inc. indicated as Seller on the invoice provided to the original purchaser of the LED 
lighting Product. Seller warrants that the Product will be free of defects in material and workmanship which cause the Product 
to fail to operate in accordance with the performance specifications set forth in the documentation published for or provided 
with the Product (the “Specifications”). The determination of whether the Product is defective shall be made by Seller in its sole 
discretion with consideration given to the overall performance of the Product. 

A Product shall not be considered defective 

NOTE

The information in this manual may not be copied or distributed without the 
written consent of Aquarii, Inc. The goal of this manual is to provide basic 
information regarding the material herein. Any other use is prohibited.

Summary of Contents for RHEOS

Page 1: ...P N 30 00302 ZINO Slope Recessed Installation Manual DO NOT DISCARD THIS MANUAL ...

Page 2: ...gs 1 Aquarii Warranty 1 Schedule A 3 Aquarii Product Return Policy 3 Mounting Option 4 Slope Recessed 4 Wiring Connections 5 Secure Power Connections 5 Communication Connections 6 Secure DMX RDM Connection 6 DMX Addressing Information 7 DMX over CAT5e 6 7 Secure 0 10V Connection 8 0 10V Information 9 Troubleshooting Corrective Actions 9 ...

Page 3: ...y installation or mounting procedures Do not connect the fixture to an electrical system that does not provide grounding equipment Do not connect the fixture to a power source with a Voltage AC level outside the fixture parameters The fixture cannot be hung with supply wires or wire connectors Wiring MUST NOT come into contact with any surfaces that have sharp edges to ensure personal product safe...

Page 4: ...ive of Seller improper or unauthorized use installation handling storage alteration maintenance or service including failure to abide by any product classifications or certifications or failure to comply with any applicable standards codes recommendations product specification sheets or instructions of Seller use of the Product with products processes or materials supplied by any end user or third...

Page 5: ...e to receive a RMA Number for your return Product s returned without a RMA will delay or may void any return credit 2 Clearly note the RMA Number on the shipping container and packing slip 3 Please return all product s as freight prepaid unless instructed otherwise by customer service 4 Include all paperwork provided by Aquarii such as the Warranty Claim 5 Ship all returns to the following address...

Page 6: ...eters based on the present building material 3 Loosen the Adjustment Nuts to adjust the orientation of the fixture inside the Box Assembly then tighten the Adjustment Nuts to secure the fixture in the desired orientation 4 If a Trim Ring is required proceed to Step 5 if not then Proceed to the Wiring Connections section of this manual 5 Obtain the Trim Ring Springs from the separate packaging acco...

Page 7: ...ds of the Power Cable in the Wagos connected to the Ground Strap and Power Supply Wire Connections Site Ground Wire Ground Strap in Junction Box Site Neutral Wire Blue Lead of Power Supply Wire Connection Site Line Voltage Wire Brown Lead of Power Supply Wire Connection 3 Reinstall the Junction Box Cover 4 If additional Communication Wiring is required proceed to the corresponding section starting...

Page 8: ...0005 RJ 45 P N 17 00004 Insulation Displacement Connector IDC P N 17 00003 Screw Terminal P N 17 00002 2 Ensure the DMX Wire Harness connection from the Controller to Communication Board has not been disrupted 3 Set the fixtures DMX Address as needed NOTE All DMX Wiring should be compatible with Telecommunications Industry Association TIA EIA 485 RS 485 See the table on Page 7 of this manual for t...

Page 9: ...ay use these wires for this purpose Because of these various uses mis plugging unlike systems could cause serious damage DMX Addressing Information The Zino LED Fixture requires one DMX Channel in a universe See the example below for how to address the fixture Channel 1 Intensity 0 255 An intensity value of 0 will cause the fixture to not illuminate while a value of 255 is the highest intensity Se...

Page 10: ... 0 10V Communication Wiring to the fixture 1 Ensure the local sites power supply is shut off for personal safety 2 Determine the type of circuit present at the local site 3 Secure the Screw Terminal Plug in Connection from the local site to the 0 10V Communication Board 4 Confirm the Polarity for 0 10V Communication Wiring 5 Test the fixture to ensure proper function 108 3 30 6 7 8 5 3 6 5 0 09 6 ...

Page 11: ...ctors There must be a minimum of 0 25 in between line voltage and bus terminals for Class 2 installations TROUBLESHOOTING CORRECTIVE ACTIONS Troubleshooting Corrective Action Assessments can only be performed by qualified trained personnel Failure to do so will void any Aquarii Product Warranties If the Zino is still not functioning as required after the Troubleshooting Corrective Actions have bee...

Reviews: