AQUAPHOR RO-31 Owner'S Manual Download Page 8

8

•  Put the shutoff all the way 

into the neck of the bowl 

(e.g. bottle, fig. 12a), or a 

vessel  wall  (e.g.  pot,  fig. 

12b).

•  Make sure that the shutoff 

is  securely  latched  (fig. 

13a, 13b).

• 

Insert the tip into the hole 

of  the  shutoff  (fig.  14a).

•  Wait for the bowl to fill 

with clean water before 

the automatic shutting off 

of  the  water  supply  and 

disconnecting the tip.

•  Disconnect the shutoff from the bowl.
• 

If you want to stop filling the bowl ahead the schedule, click on the button at the end of the shutoff (fig. 14b).

8. SYSTEM MAINTENANCE

The  service  life  of  the  membrane  module  is  directly  dependent  on  the  performance  of  the  water 

treatment unit. Therefore, it is very important to replace the filter modules on time.

To replace the K5 plug-in module:

• 

Close the inlet tap and connect the nozzle to the storage tank to relieve the pressure.

• 

Pressing the lock button fully in this position, turn the used filter module clockwise and remove it.

• 

Remove the packaging film from the new module;

• 

Insert the new module into the collector block until it stops and, lightly pressing, turn the module clockwise 

until it clicks.

• 

Open the inlet tap and make sure the RO is tight.

• 

Insert the assembled module into the collector block until it stops and, while slightly pressing, turn the 

module clockwise until it clicks.

• 

Open the inlet tap and make sure the RO is tight.

To replace the K2 plug-in module:

• 

Close the inlet tap and connect the nozzle to the storage tank to relieve the pressure.

• 

Pressing the lock button fully in this position, turn the used filter module clockwise and remove it.

• 

Remove the packaging film from the new module.

• 

Insert the new module into the collector block until it stops and, while lightly pressing, turn the module 

clockwise until it clicks.

• 

Open the inlet tap and make sure the RO is tight.

• 

Insert the assembled module into the collector block until it stops and, while slightly pressing, turn the 

module clockwise until it clicks.

• 

Open the inlet tap and make sure the RO is tight.

To replace the K2 plug-in module:

• 

Close the inlet tap and connect the nozzle to the storage tank to relieve the pressure.

• 

Pressing the lock button fully in this position, turn the used filter module clockwise and remove it.

• 

Remove the packaging film from the new module.

• 

Place the modules in the “flush” position (see fig. 9 “The position of the modules in the RO”).

• 

Open the inlet tap.

 

Figure 11a  

Figure 11b

Summary of Contents for RO-31

Page 1: ...logies Unique ion fiber Effectively and irreversibly removes heavy metals Carbon block with QUALEN completely removes chlorine organic substances and carcinogens STC Safe To Consume Materials are cert...

Page 2: ...ers length height width Located under the sink 265 365 100 mm 10 4 14 4 39 4 inches Operational parameters of the storage tank length height width Located on the countertop 280 265 110 mm 11 0 10 4 4...

Page 3: ...ls pesticides chloroformandheavymetals Membrane cartridge 2 Here water divides into two streams purified water ready for further treatment and drain water which includes unwanted impurities Clean wate...

Page 4: ...pressure in the water supply Connect the connection node to the plumbing Connect the JG 1 4 tube To do this pull the locking clip off the plastic sleeve install the plastic tube previously wetted with...

Page 5: ...e end of the threaded tail 1 to the sleeve 6 should be approx 600 mm Collector block installation Fix the block to make the distance under the water purifier with no less than 50 mm of free place It i...

Page 6: ...hen pull the tube Step 2 Install the filter cartridges Remove thermostatic tape and transporting plugs from the cartridges Make sure that the inside surfaces of the subunit flange cartridges are clean...

Page 7: ...y disconnected If you want to stop the filling of water into the bowl ahead of schedule just press the button located on the top of the bowl cover Return the nose into the cradle not later than 1 hour...

Page 8: ...clicks Open the inlet tap and make sure the RO is tight Insert the assembled module into the collector block until it stops and while slightly pressing turn the module clockwise until it clicks Open...

Page 9: ...into the sink then drain the water from the water purifier for 1 hour Disconnect the tip from the shutoff by pressing the button located on the shutoff end fig 14b Make sure the RO is sealed Condition...

Page 10: ...nd workmanship under normal use and service Aquaphor RO 31 One Year Warranty Depending on the amount of impurities in the water the service life resource of the water treatment cartridges may vary may...

Page 11: ...AL DAMAGES OR EXPENSES INCURRED BY THE PURCHASER OR FOR LABOR OR OTHER COSTS DUE TO INSTALLATION OR REMOVAL OR COSTS OF REPAIRS BY OTHERS OR FOR ANY OTHER EXPENSE NOT SPECIFICALLY STATED ABOVE EXCEPT...

Page 12: ...e engineer Service engineer s signature Client s signature For installation operational and technical maintenance please contact Manufacturer EE Westaqua Invest O division of Aquaphor Corp L Tolstoi 2...