AQUAPHOR RO-202S Operation Manual Download Page 9

9

ATTENTION! If leaks are found, immediately  
turn the inlet cock of the connecting assembly 
to its closed position and check the connections. 
Turn the inlet cock of the connecting assembly to 
its open position again to continue the flushing 
procedure after the leak is repaired. 

•  After the flushing procedure is complete, your 

RO-202S beeps 5 times and switches into the 

operating mode automatically.

•  Turn the inlet cock of the connecting assembly 

to its closed position and wait when the 

cartridge life light and sound indication turns off.

Step 4. Flushing the reverse osmosis 

membrane unit

•  Remove the service plug from the slot of the 

reverse osmosis membrane unit and replace it 

with the membrane cartridge as shown in Fig. 1

•  Turn the inlet cock of the connecting assembly 

to its open position. The cartridge life indicator 

lights blink (the light signal is be followed by 

an audible one). 

•  Make sure the RO-202S connections are tight.

Attention! If leaks are found, immediately turn 
the inlet cock of the connecting assembly to its 
closed position and check the connections. Turn 
the inlet cock of the connecting assembly to its 
open position again to continue the flushing 
procedure after the leak is repaired.

•  Wait for the water to flow from the tap for treated 

water. 

•  Let the water through your RO-202S for 1 hour.* 

•  Close the treated water tap.

Step 5. Flushing the water  

conditioning unit

•  Fill the storage tank with water (the light and 

sound indication turns off), open the tap for 

treated water and wait when all the water has 

drained from the storage tank (a weak water 

flow from the tap).

•  Close the treated water tap.

•  Fill and empty the storage tank 2 more times.

•  Press and hold the PUSH button for at least 

7 seconds. The cartridge life light indication 

changes from the flashing mode to the constant 

one, and the audio signal stops.

•  Make sure the RO-202S connections are tight.

Fig. 13

Fig. 14

* The whole flushing procedure of the membrane cartridge takes no more than 24 hours and depends on its storage and transpor-

tation conditions.

•  Your RO-202S is ready for use once the tank 

is filled.

ATTENTION! The water is not intended for drink-
ing after flushing.

Periodically check your RO-202S for leaks during 

the first week of use.
Some noise may occur during the first week of 

operation of your RO-202S when switching the 

valve because of air released from the internal 

cavities of the system. This is not a malfunction.

Membrane 

Membrane 

cartridge

cartridge

Summary of Contents for RO-202S

Page 1: ...RO 202S REVERSE OSMOSIS SYSTEM Operation manual...

Page 2: ...easing water salinity so the higher the water salinity the greater water supply pressure is required to keep RO 202S operating RO 202S is made of safe non toxic materials ensuring that no substances h...

Page 3: ...s 6 3 1 1 4 JG tube d 6 35 mm L 1 3 m red 1 pc 3 2 1 4 JG tube d 6 35 mm L 1 2 m black 1 pc 3 3 1 4 JG tube d 6 35 mm L 1 0 m blue with an inserted metal bushing 1 pc 4 Connecting assembly 7 1 set 5 D...

Page 4: ...e filter cartridges are part of the water pre treatment unit 2 The water pre treatment unit is designed to remove impurities from the water such as iron hydroxide and active chlorine that can damage t...

Page 5: ...your RO 202S and the treated water tap Attention should paid to prevent the supply tubes from bending and twisting Fig 3 Your RO 202S must be installed far from or insu lated from heat sources stoves...

Page 6: ...et cock is in its closed position Retaining clip Connecting assembly Gasket Cold water supply The manufacturer reserves the right to use connecting assemblies and taps of a similar design If you have...

Page 7: ...he two parts of the clamp are parallel Put the plastic nut on the JG drain tube so that the tube extends from the other side of the nut by at least 20 mm Fig 7b Insert the tube into the drain clamp an...

Page 8: ...ert the plug of the power supply into the outlet and the plug from the power supply into the socket in your RO 202S unit Fig 12 Step 3 Flushing the pre treatment unit Open the treated water tap Turn t...

Page 9: ...s open position again to continue the flushing procedure after the leak is repaired Wait for the water to flow from the tap for treated water Let the water through your RO 202S for 1 hour Close the tr...

Page 10: ...necting assembly and open the treated water tap Wait when the cartridge life light and sound indication turns off Remove the overwrapping film from the new cartridges Rinse the O rings of the new cart...

Page 11: ...ng mode to the constant one and the audio signal stops ATTENTION Do not disconnect your RO 202S from the power supply when in the flushing mode Otherwise the flushing process must be repeated After re...

Page 12: ...o treat unknown water without additional disinfection Empty and refill the tank 3 times for flushing before use if you have not used your system for more than 2 weeks Treated water is not subject to l...

Page 13: ...s its products to be free from manufacturing defects under normal use and service This warranty is extended only to the ORIGINAL PURCHASER 2 Aquaphor obligations under this warranty are limited to rep...

Page 14: ...BM is clogged Replace the replaceable cartridge of the water conditioning unit K7BM The emergency mode is activated light indicator 5 flashes on the front panel see page 10 Contact your service provid...

Page 15: ......

Page 16: ...or Corp L Tolstoi 2A Sillam e Estonia 40231 www aquaphor com The manufacturer reserves the right to make improvements to the design of the RO 202S without being mentioned in this Manual The date of ma...

Reviews: