AQUAPHOR RO-202S Operation Manual Download Page 12

12

Protect your RO-202S from shocks and falls, as 

well as do not let water freeze when transporting, 

storing and using.
Do not expose the membrane cartridge to high 

or low temperatures and direct sunlight.  

ATTENTION! Membrane cartridges come in 
sealed packaging. It is allowed to store mem-
brane cartridges for no more than 3 days after 
they are unpacked.

10. Safety

RO-202S is designed to post-treat and soften 

water from municipal water supply systems that 

meet sanitary standards.
It is recommended to analyse the source water for 

compliance with national standards for drinking 

water when installing RO-202S outside municipal 

water supply systems.

•  The service life of the pre-treatment unit 

and the reverse osmosis membrane may be 

reduced if the source water does not meet 

the requirements of national standards for 

drinking water.

•  It is recommended to install additional water 

treatment systems (iron removers, softeners, 

disinfectants, mechanical filters, etc.) if the 

source water significantly differs from the 

requirements of national standards for  

drinking water.

•  It is recommended to analyse the treated water 

for compliance with national standards for 

drinking water after your RO-202S is installed.

•  Further, the treated water should be tested 

regularly (once a year) to make sure your  

RO-202S functions properly.

•  An additional test is recommended if the taste 

or smell of the water changes.

•  If the test results are unsatisfactory, it is not 

allowed to drink the water, and you should 

contact your service provider.

•  It is recommended to use RO-202S as a post-

treatment unit for microbiologically safe water, 

although this reverse osmosis system can trap 

out bacteria and viruses from the source water.

•  Do not use the system to treat unknown water 

without additional disinfection.

Empty and refill the tank 3 times for flushing 

before use if you have not used your system for 

more than 2 weeks.
Treated water is not subject to long-term storage. 

It is recommended to use fresh filtered water. It 

is disposed of in accordance with environmental, 

sanitary and other requirements set forth in 

national standards for environmental protection 

and ensuring the sanitary and epidemiological 

welfare of the population. 

Precautions when connecting your RO-202S to the mains

Check that the main voltage matches the parameters specified in this Manual before connecting 

your RO-202S to the mains. Only use a power supply unit with output characteristics specified 

in this Manual (24 V ± 5%, at least 1.5 A DC).
Make sure that your RO-202S is protected from freezing, water, direct sunlight, contact with 

hot objects, including hot water, heating pipes and heating devices before installing. Keep your 

RO-202S from hitting and falling.
The power cord must not be tensioned when your RO-202S is connected. Make sure that the 

power cord does not touch surfaces that could damage it.
Do not immerse your RO-202S, as well as the power supply unit, the power cord and the plug 

of the power cord in water or other liquid, or wash them with running water or in a dishwasher.

To avoid electric shock, do not touch your RO-202S connected to power with wet hands, as 
well as the power supply unit, the power cord and the plug.

Keep your RO-202S housing clean. Disconnect your RO-202S from the power supply and wipe, 

if necessary, with a dry cloth.

Do not disassemble your RO-202S nor open its housing!

Do not use the RO-202S and the power supply in case of malfunction or damage to the cord. Do 

not repair the device yourself. First disconnect the power supply from the mains, then disconnect it 

from the RO-202S if any malfunction is detected. It is recommended to contact your service provider.

Summary of Contents for RO-202S

Page 1: ...RO 202S REVERSE OSMOSIS SYSTEM Operation manual...

Page 2: ...easing water salinity so the higher the water salinity the greater water supply pressure is required to keep RO 202S operating RO 202S is made of safe non toxic materials ensuring that no substances h...

Page 3: ...s 6 3 1 1 4 JG tube d 6 35 mm L 1 3 m red 1 pc 3 2 1 4 JG tube d 6 35 mm L 1 2 m black 1 pc 3 3 1 4 JG tube d 6 35 mm L 1 0 m blue with an inserted metal bushing 1 pc 4 Connecting assembly 7 1 set 5 D...

Page 4: ...e filter cartridges are part of the water pre treatment unit 2 The water pre treatment unit is designed to remove impurities from the water such as iron hydroxide and active chlorine that can damage t...

Page 5: ...your RO 202S and the treated water tap Attention should paid to prevent the supply tubes from bending and twisting Fig 3 Your RO 202S must be installed far from or insu lated from heat sources stoves...

Page 6: ...et cock is in its closed position Retaining clip Connecting assembly Gasket Cold water supply The manufacturer reserves the right to use connecting assemblies and taps of a similar design If you have...

Page 7: ...he two parts of the clamp are parallel Put the plastic nut on the JG drain tube so that the tube extends from the other side of the nut by at least 20 mm Fig 7b Insert the tube into the drain clamp an...

Page 8: ...ert the plug of the power supply into the outlet and the plug from the power supply into the socket in your RO 202S unit Fig 12 Step 3 Flushing the pre treatment unit Open the treated water tap Turn t...

Page 9: ...s open position again to continue the flushing procedure after the leak is repaired Wait for the water to flow from the tap for treated water Let the water through your RO 202S for 1 hour Close the tr...

Page 10: ...necting assembly and open the treated water tap Wait when the cartridge life light and sound indication turns off Remove the overwrapping film from the new cartridges Rinse the O rings of the new cart...

Page 11: ...ng mode to the constant one and the audio signal stops ATTENTION Do not disconnect your RO 202S from the power supply when in the flushing mode Otherwise the flushing process must be repeated After re...

Page 12: ...o treat unknown water without additional disinfection Empty and refill the tank 3 times for flushing before use if you have not used your system for more than 2 weeks Treated water is not subject to l...

Page 13: ...s its products to be free from manufacturing defects under normal use and service This warranty is extended only to the ORIGINAL PURCHASER 2 Aquaphor obligations under this warranty are limited to rep...

Page 14: ...BM is clogged Replace the replaceable cartridge of the water conditioning unit K7BM The emergency mode is activated light indicator 5 flashes on the front panel see page 10 Contact your service provid...

Page 15: ......

Page 16: ...or Corp L Tolstoi 2A Sillam e Estonia 40231 www aquaphor com The manufacturer reserves the right to make improvements to the design of the RO 202S without being mentioned in this Manual The date of ma...