All debris will now be flushed through the filter cleaning the coil and draining off via
the drain valve.
When all the debris is removed then reverse the cleaning procedure, ensuring that
the dump valve is closed and the magnet reinserted into its position.
Ensure that all dirty water dumped in the procedure is replaced with clean.
ASSEMBLY
Using the female swivel fittings, screw the two lengths of hose provided to the “flow”
and “return” 3/4” mi threads as clearly indicated in the centre at the base of the
protection plate, fitted to the rear of the SUPAFLUSH pump.
Supply three own hoses, and with the protection plate facing towards you connect as
follows:-
1. Clean cold water supply to the water inlet tap situated on the tank top, as indicated
on the bottom left of the protection plate.
2. Connect to 3/4” mi joint valve dump outlet situated on the top of the protection
plate, and route direct to drain.
3. Connect to the flushing tank overflow situated on the L/H side of the tank as
indicated on the protection plate and route directly to the drain.
ALL FITMENT POSITIONS ARE CLEARLY INDICATED ON THE PROTECTION PLATE
The pump is supplied with various adaptors to facilitate system connection at the
point most suitable for each individual system ie radiators or boiler.
water inlet tap
overflow