CONNECTIONS – PLUMBING 

 
All plumbing work must be carried out by a qualified person and in accordance 
with the Standard AS/NZS 3500.4 and  all local codes  and regulatory authority 
requirements. 
 

CONNECTION SIZES 

 

Hot water connection:   

Rp 3/4 

 

Cold water connection:  

Rp 3/4 

 

Relief valve connection: 

Rp 1/2 

 

WATER INLET AND OUTLET 

Each model water heater has dual handed cold and hot water connections. The 
water connections can be made to either side. 
 
All pipe work must be cleared of foreign matter before connection and purged 
before attempting to operate the water heater. All olive compression fittings must 
use brass or copper olives. Use an approved thread sealant such as Teflon tape 
on all sealing threads. 
 
An  isolation  valve  and  non-return 
valve  must  be  installed  on  the  cold 
water  line  to  the  water  heater.  An 
acceptable arrangement is shown in 
the  diagram.  Refer  also  to 

“Hot 

Water  Delivery”

  on  page 29  and  to 

“Mains Water Supply”

 on page 28. 

 
A  disconnection  union  must  always 
be  provided  at  the  cold  water  inlet 
and  hot  water  outlet  on  the  water 
heater  to  allow  for  disconnection  of 
the water heater. 
 
This water heater has either a plastic dip tube or fitting 
liner in the inlet and outlet fittings (see diagram). These 
must  be  in  place  for  the  water  heater  to  function 
properly.  Do  not  remove  or  damage  them  by  using 
heat  nearby.  They  will  be  pushed  into  the  correct 
position as the fitting is screwed in. 
 
This water heater is intended to be permanently connected to the water mains 
and  not  connected  by  a  hose-set.  A  braided  flexible  hose  or  semi-flexible 
connector may be used for connection to the water heater, where permitted by 
AS/NZS 3500.4. 

 

 

 

 

 

Summary of Contents for 971 Series

Page 1: ...This water heater must be installed and serviced by a qualified person Please leave this guide with the householder Owner s Guide and Installation Instructions Electric Domestic Water Heater...

Page 2: ...Ltd TRADEMARKS Registered trademark of Aquamax Australia Pty Limited or Rheem Australia Pty Ltd TM Trademark of Aquamax Australia Pty Limited or Rheem Australia Pty Ltd Note Every care has been taken...

Page 3: ...the terms of the Aquamax warranty on pages 4 to 7 The other pages are intended for the installer but may be of interest Warranty 4 Safety Warnings Installation Notes 8 About Your Water Heater 12 Maint...

Page 4: ...heaters manufactured from 1st December 2018 1 5 If a subsequent version of this warranty is published the terms of that warranty and what is covered by it will apply to water heaters manufactured aft...

Page 5: ...This warranty only applies to the original and genuine Aquamax water heater in its original installed location and any genuine Aquamax replacement parts 2 8 The Aquamax warranty does not cover faults...

Page 6: ...ply the hot water demand in accordance with the guidelines in the Aquamax water heater literature any resultant fault will not be covered by the Aquamax warranty 3 WHAT IS COVERED BY THE AQUAMAX WARRA...

Page 7: ...contact number and date of installation of the water heater or if that s unavailable the date of manufacture and serial number from the rating label on the water heater b Aquamax will arrange for the...

Page 8: ...ices must not be tampered with or removed The water heater must not be operated unless each of these devices is fitted and is in working order The Aquamax warranty may not cover faults if relief valve...

Page 9: ...Western Australia and scaling water areas it is mandatory an expansion control valve is fitted to the cold water line to the water heater The expansion control valve will discharge the quantity of wa...

Page 10: ...erature pressure relief valve should be replaced at intervals not exceeding five 5 years and the expansion control valve should be checked for performance or replaced at intervals not exceeding five 5...

Page 11: ...l worker are contained on pages 26 to 42 Mains pressure water supply The water heater is designed to operate at mains pressure by connecting directly to the mains water supply The water heater is supp...

Page 12: ...ted to the water heater to provide safe and efficient operation The water heaters have connections on either side of the tank Plugs block off the alternative connection points A 160 model has caps cov...

Page 13: ...o the kitchen and laundry THERMOSTAT The thermostat automatically controls the electricity supply to the heating unit so a constant temperature is maintained The thermostat and its protective over tem...

Page 14: ...th its own thermostat One heating unit is at the base of the water heater and the other near the top Bottom heating unit During normal operation this heating unit supplies all the hot water Top heatin...

Page 15: ...upply system TO TURN OFF THE WATER HEATER If you plan to be away from home for only a few nights we suggest you leave the water heater switched on If it is necessary to turn off the water heater Switc...

Page 16: ...THE WATER HEATER The water heater is suitable for most public water supplies however some water chemistries may have detrimental effects on the water heater its components and fittings Refer to Water...

Page 17: ...lief valve Inspect and flush the expansion control valve if fitted If required replace the valve Inspect and if required replace the anode If the anode is not replaced it should be replaced within fiv...

Page 18: ...ised and lowered gently Refer to Relief Valves on page 9 Warning Water discharged from the temperature pressure relief valve drain line will be hot Exercise care to avoid any splashing of water by sta...

Page 19: ...lour coded anode is used If an incorrect colour coded anode is used in the water heater any resultant faults will not be covered by the Aquamax warranty In addition the use of an incorrect colour code...

Page 20: ...eater than 600 mg L and the anode has not been changed to a blue anode there is the possibility the anode may become overactive and hydrogen gas could accumulate in the top of the water heater during...

Page 21: ...apply to the temperature pressure relief valve and water heater cylinder Where the saturation index exceeds 0 80 the Aquamax warranty does not apply to a standard watts density heating unit A low wat...

Page 22: ...in these guidelines for the Aquamax warranty to apply SUMMARY OF WATER CHEMISTRY ADVICE AFFECTING WARRANTY The water heater and its components are not suitable for certain water chemistries Those chem...

Page 23: ...t water heaters A twin element non simultaneous model must have power available to the top heating unit circuit at all times for the water heater to operate as designed Are you using more hot water th...

Page 24: ...t has a lower pressure rating A benefit is that energy is conserved as the discharged water is cooler This valve is installed in the cold water line to the water heater refer to the cold water connect...

Page 25: ...plumber rectify any leaking pipe work Has there been an increase in hot water usage An increase in hot water usage will result in an increase in water heater operation Has your water heating tariff ra...

Page 26: ...aterials must be removed from the water heater prior to its installation This includes the removal of the cardboard base of the carton from the underside of the water heater WATER HEATER APPLICATION T...

Page 27: ...base as acceptable to local authorities The base of the water heater is made of corrosion resistant material and it may be placed directly in contact with the supporting surface It is not necessary t...

Page 28: ...a full flow gate valve or ball valve ANODE The vitreous enamel lined cylinder of the water heater is only covered by the Aquamax warranty when the total dissolved solids TDS content in the water is le...

Page 29: ...or personal hygiene such as in a bathroom ensuite public amenities or other ablution areas to reduce the risk of scalding Where a temperature limiting device is installed adjacent to the water heater...

Page 30: ...return pipe If circulated tempered water were to be returned back to the water heater depending on the location of the return line connection on the water supply line to the water heater then either w...

Page 31: ...ater The flow and return lines connect to the secondary water heater not the Off Peak electric water heater The secondary water heater makes up for the pipe heat loss in the flow and return system and...

Page 32: ...E WORK To prevent damage to the cylinder when attaching pipe clips or saddles to the water heater jacket we recommend the use of self drilling screws with a maximum length of 13 mm Should pre drilling...

Page 33: ...INSTALLATION 33 TYPICAL INSTALLATION OUTDOOR LOCATION TYPICAL INSTALLATION INDOOR LOCATION...

Page 34: ...0 680 680 730 D mm 1332 642 1112 1317 1479 E mm 104 113 73 113 121 F mm 66 103 103 103 105 G mm 988 1228 1323 H deg 23 32 32 32 30 J deg 58 88 88 88 83 M deg 58 92 92 92 97 TPR Valve Setting kPa 1400...

Page 35: ...lve and non return valve must be installed on the cold water line to the water heater An acceptable arrangement is shown in the diagram Refer also to Hot Water Delivery on page 29 and to Mains Water S...

Page 36: ...Tighten the plugs using a 3 8 square driver Fit a plastic cap where supplied with its insulation rubber disc over each plug PIPE SIZES To achieve true mains pressure operation the cold water line to...

Page 37: ...ing Do not use a pipe wrench or poor fitting tool on the valve body nor over tighten the valve as this could damage the valve and prevent safe operation Operate the easing lever on the valve to check...

Page 38: ...as short as possible have a continuous fall all the way from the water heater to the discharge outlet and have no tap valves or other restrictions in the pipe work A drain line from a relief valve mu...

Page 39: ...as for a drain line from a relief valve Warning As the function of the temperature pressure relief valve on this water heater is to discharge high temperature water under certain conditions it is stro...

Page 40: ...ff Peak overnight and day or continuous electricity supply depending upon the size of the water heater Check with the local electricity supply authority as to their requirements An Off Peak overnight...

Page 41: ...ts with the householder WIRING DIAGRAM TWIN ELEMENT ELECTRIC WATER HEATERS NON SIMULTANEOUS OPERATION OFF PEAK CONNECTION Top thermostat fixed setting 60 C Bottom thermostat tradesperson adjustable mi...

Page 42: ...the easing lever on the temperature pressure relief valve to check the smooth operation of the valve plunger and that water discharges freely from the drain line It is very important the lever is rais...

Page 43: ...t the lever snap back or you will damage the valve seat It is very important the lever is raised and lowered gently Operating the lever will release the pressure in the water heater Undo the union at...

Page 44: ...upon completion of the installation This information should be provided to assist the customer in an event that a claim is to be made under the Aquamax warranty Plumber Name Company Plumber s Licence...

Reviews: