![Aqualisa Visage Digital Exposed Installation Instructions Manual Download Page 5](http://html1.mh-extra.com/html/aqualisa/visage-digital-exposed/visage-digital-exposed_installation-instructions-manual_2960145005.webp)
Visage Digital exposed
installation instuctions
page 5
Important information
Connections
This product incorporates ‘push fit’ type connections. Tube should be cut using a rotary type cutter and lubricated using a
silicone-based lubricant or petroleum jelly (Vaseline or similar) prior to insertion into the fitting.
If plastic pipe is used, the tube insert must not increase the tube diameter or extend the cut-off length by more than 2mm.
TO MAXIMISE FLOW RATES WE RECOMMEND USING COPPER PIPE WITH THE MINIMUM AMOUNT OF ELBOWS.
THESE FITTINGS ARE NOT SUITABLE FOR STAINLESS STEEL TUBE.
Pipe sizing
Long pipe runs, particularly on the outlet, will reduce the flow rate at the shower head. If long pipe runs are unavoidable, use
copper pipe rather than plastic. If plastic pipe is used, minimise the number of elbows as the pipe inserts are very restrictive.
Consideration should be given to using 22mm plastic or copper pipe on the outlet especially if a diverter is installed.
Flushing
Some modern fluxes can be extremely corrosive and, if left in contact, will attack the working parts of this unit. All soldering must
be completed and the pipe work thoroughly flushed out in accordance with current Water Supply Regulations prior to connection
of the product.
After installation
Familiarise the end user with the Visage Digital operation and hand them this guide. Complete and post the guarantee card
or register online at www.aqualisa.co.uk