Aqualisa OPTIC Q User Manual Download Page 23

Error/Message

Suggestions and Checks

“Could not connect to the 
shower”

If a serial number is displayed, tap on 

Try Again. If no serial 

number displayed tap on 

Cancel and then go through the 

process again, ensuring that the below suggestions are followed.

“Network unavailable”
            Or
Wifi drops when 
connecting to the QSVC

Note: The setup process requires good signal strength between 
your phone and the SmartValve™ (not the shower controller).
Close any running apps on the phone before commencing.
Turn off the mobile data connection in the phone’s settings.
Select "Keep WiFi Connection with No Internet" where and when 
prompted.
Ensure that your phone / smart device is connected to the home 
Wifi network (try running a program or app that requires Wifi 
connection).
Close and re-open the Aqualisa app.
In the app journey ensure that QSVC is being selected and that 
the password SmartShower is entered correctly- you do not 
have to wait for connection confirmation, once QSVC has been 
selected wait a few seconds and then return to the Aqualisa app.
Ensure that you are keying your SSID (home Wifi) and password 
correctly.

“The operation could not 
be completed” (when 
trying to start shower)

Ensure your Wifi is working.
Check that the shower operates using the main controller.
If the shower does not work via the main controller, check there 
is power to the Aqualisa SmartValve™ (possibly tripped fuse / 
circuit or accidentally switched off).
Turn power off to the SmartValve™ for a few minutes and then 
reinstate.
Close any other running apps.

The app is missing the 
profile feature (Touch and 
Optic models only)

Follow the below instructions:
Select HOME.
Select the SHOWERS tab, if it states “Reduced” follow the below 
instruction:
Swipe the shower model left or select the arrow and then tap on 
"Disconnect from shower".
Select Add new shower and follow the set up (Connecting 
shower) steps as per instructions.

Locating the shower serial 
number in the Aqualisa app

From the Home Tab, select the SHOWERS tab, then choose the 
shower to display the serial number.

App Troubleshooting

For further assistance utilise the Instabug reporting platform - see details on page 15.

23

Summary of Contents for OPTIC Q

Page 1: ...OPTIC USER GUIDE...

Page 2: ...ory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Chil...

Page 3: ...o date with latest features for the Aqualisa app and voice activation by visiting the Aqualisa website Download and open the free Aqualisa app Find instructions on page 15 Connecting to the App If you...

Page 4: ...Push and hold QTM lever for over 3 seconds then release when desired outlet icon appears Adjust during showering only Adjust before or during showering Divert models only You can prepare your temperat...

Page 5: ...rds the controller the display wakes up and is ready to go You can disable this feature in the Settings menu see page 12 Wake up The proximity sensor detects any object directly in front at approximat...

Page 6: ...the shower STARTING YOUR SHOWER To activate the controller use the proximity sensor or touch the power symbol until the screen wakes up then push and release the lever to start the shower The Get Rea...

Page 7: ...urn clockwise to increase the temperature While the temperature is adjusting the screen will flash and the display will show Warming When the desired temperature is reached the display will stop flash...

Page 8: ...w 39 FLOW FEEDBACK DISPLAY After adjusting the flow the display will return to the temperature Home screen after a few seconds From the Home screen you can adjust the flow during showering by moving t...

Page 9: ...ernate between outlets by pushing and holding the lever for over 3 seconds and releasing when the desired outlet icon appears This can be done upon starting the shower or during showering OUTLET ICONS...

Page 10: ...ly but firmly pulling forwards or pushing back the shower head against the ratchet in the holder Removing the shower head With the hose still attached disengage the pivot clip by pushing in the outer...

Page 11: ...erfilled this may not be sufficient to prevent the bath from overflowing depending on system conditions The angle of the fixed shower head can be adjusted The shower head is mounted on a multi directi...

Page 12: ...pear to confirm your choice Settings Optic Q features optional settings to enhance your shower To enter Settings from the Home Screen move the lever left or right until the Settings screen appears Pus...

Page 13: ...e shower functionality using your personal smart devices Wifi Auto Wake up AUTO WAKE UP This setting allows the Wake Up feature to be turned off This may be required if you have a small shower enclosu...

Page 14: ...installation When you have selected the icons your choice will be confirmed with OK This setting enables you to choose the icons that represent your outlets If you have multiple outlets you can also s...

Page 15: ...ort can be raised To trigger the Instabug service either shake your smartphone from side to side or tap on the message bubble then simply follow the instructions Home Wifi Network Before starting you...

Page 16: ...www aqualisa co uk smartapp Set up Shower Wifi The Aqualisa app will direct you to the Wifi settings menu on your mobile device From the list of available Networks select QSVC XXXX The password is Sm...

Page 17: ...that baths and showers in operation are not left unattended Auto Wake up The Proximity Sensor AUTO WAKE UP The controller has a proximity sensor so as you approach or move your hand towards the contr...

Page 18: ...rocedure should be completed regularly as often as once a week in some hard water areas as scale build up can affect the spray pattern and cause the shower to perform poorly Failure to descale the sho...

Page 19: ...e flow starts to splutter stop moving the temperature control until the flow again stabilises then continue to move the dial towards the hottest setting Restriction in the waterway Check for debris in...

Page 20: ...t the filters are clear check with the local water authority Separate stand alone pump not activating Standard Aqualisa SmartValveTM only Ensure sufficient flow to activate the flow switches of the pu...

Page 21: ...es not stabilise Hot water supply issue Check another hot water outlet to ensure that hot water is available Mixed water supplies Water supplies MUST be from the same source MUST NOT be gravity hot an...

Page 22: ...ring Diagram Section in the Smart Installation Guide Outlets not configured Turn off the power supply to the Aqualisa SmartValveTM leave isolated for at least 2 minutes Reinstate power supply and then...

Page 23: ...n selected wait a few seconds and then return to the Aqualisa app Ensure that you are keying your SSID home Wifi and password correctly The operation could not be completed when trying to start shower...

Page 24: ...a totally free of charge 1 year parts and labour guarantee You can easily increase your FREE guarantee to 5 years simply by registering your product Please keep your receipt to validate your guarante...

Page 25: ...ak to our Customer Service team on 01959 560010 Use Live Chat at aqualisa co uk Or email us at enquiries aqualisa co uk Instabug reporting platform for the Aqualisa app Accessed in the app by Shaking...

Page 26: ...Notes 26...

Page 27: ...Notes 27...

Page 28: ...right to alter change or modify the product specifications without prior warning Registered Trademark Aqualisa Products Limited Q5285 Part No 705145 Issue 03 Dec 20 THE FLYERS WAY WESTERHAM KENT TN16...

Reviews: