Page 1: ...Dual exposed shower with fixed and adjustable shower heads installation instuctions page 1 Dual Exposed shower with fixed and adjustable shower heads ...

Page 2: ...Dual exposed shower with fixed and adjustable shower heads installation instuctions page 2 Shower systems Exposed shower with fixed and adjustable shower heads ...

Page 3: ...Dual exposed shower with fixed and adjustable shower heads installation instuctions page 3 Components ...

Page 4: ... unit Any debris accumulation in the shower valve and head may result in damage and poor performance Flushing Some modern fluxes can be extremely corrosive and if left in contact will attack the working parts of this unit All soldering must be completed and the pipe work thoroughly flushed out in accordance with current Water Supply Regulations prior to connection of the product Filters To ensure ...

Page 5: ... shower is in use Boosted gravity fed hot and cold supplies Services must be installed according to good plumbing practice having regard to pipe sizing long pipe runs and low head situations Pump installation PLEASE REFER TO THE MANUFACTURERS PUMP INSTALLATION GUIDE FOR PUMP INSTALLATION INFORMATION UNDER NO CIRCUMSTANCES MUST A PUMP BE FITTED DIRECTLY TO THE WATER MAIN A pump must only be used to...

Page 6: ...alve The exposed valve and fixing bracket assembly MUST NOT be used as a grab rail support method If required apply jointing tape to the threads and fit the eccentric elbow connectors sufficiently to achieve a water tight seal terminating at 150mm centres to suit the exposed valve inlets 2 Ensuring adequate provision to allow the water to discharge safely to waste turn on the supplies to flush the...

Page 7: ...the valve control knob levers and set aside 6 Secure the grub screws to the valve control knobs using the hexagonal key provided and fix the levers to the control knob assemblies 7 Ensuring the sealing washer is in position secure the top outlet valve connector to the valve and tighten using a suitable tool taking care not to overtighten 9 Ensuring the handset cradle is on the left hand side of th...

Page 8: ...he riser tube assembly to conceal the join between the straight and formed riser tubes 5 Ensuring the riser tube assembly has been correctly positioned and attached to the mixer valve mark the position of the fixing plate Remove the riser tube assembly from the valve and remove the bracket assembly from the riser rail 6 Remove the fixing plate from the wall bracket assembly using the hexagonal key...

Page 9: ...n Turn the shower on towards the wall to allow the water to discharge safely to waste and run the shower for a few seconds to clear any debris in the outlet assembly This process can also be repeated for the fixed head by adjusting the control knob away from the wall 14 Ensuring the flat washer is in place carefully screw the shower head to the formed arm taking care not to damage the plated surfa...

Page 10: ...e the handset to the hose Once tightened carefully pull the handset away from the hose to release the integral anti kink swivel connection Place the handset into the handset holder 16 The tension of the handset station to the handset holder is factory set However it may be necessary especially for showers fitted to high pressure systems to tighten the tension as required Tighten the screw inside t...

Page 11: ... ATTEMPT TO MAKE ANY ADJUSTMENT TO THE SHOWER HEAD BY PULLING ON THE SHOWER HOSE 1 To select the preferred height for the shower head press the handset holder button to enable the slider to be moved up or down the rail 2 Angular adjustment is made by carefully but firmly pulling forwards or pushing back the shower head against the knuckle in the handset holder 3 To select the desired spray pattern...

Page 12: ...M temperature setting We recommend the MAXIMUM outlet temperature is set to 46OC 8 Turn the valve off 9 Using a suitable tool remove the maximum temperature stop ring 10 Reposition the temperature stop ring ensuring the maximum temperature stop point aligns with the markings on the temperature spline 11 Refit the temperature control knob onto the valve with a temperature lever fixing point in the ...

Page 13: ...5 c hotter than the blend Check the flow rate recommendations with the heater manufacturer Adjust the flow control knob on the mixer valve to reduce flow until a comfortable showering temperature is achieved Flow rate is poor and water temperature is low Airlock in the water supply Check that the pipe work is laid in accordance with the correct practices paying particular attention to potential ai...

Page 14: ...of Ireland 01 844 3212 Brochure Hotline 0800 652 3669 Website www aqualisa co uk Email enquiries aqualisa co uk Please note that calls may be recorded for training and quality purposes The company reserves the right to alter change or modify the product specifications without prior warning Registered Trademark Aqualisa Products Limited Part No 649601 Issue 01 Nov 10 ...