Remove the gripper ring assembly from the
rear of the back plate and ensuring correct
alignment of the gripper rings, slide over the
projecting pipes flush to the wall face.
Cut the supply pipes to their finished length
(18mm – 21mm) and the 22m outlet pipe
(17mm - 28mm) using a rotary type cutter.
5
Briefly run the hot and cold supplies to flush out any debris that may be
present in the system.
6
Remove the four cartridge fixing screws and
carefully detach the cartridge assembly from
the back plate.
7
If the valve is being installed for use with a gas
fired instantaneous (multipoint) water heater
or a combination boiler, the cold water flow
regulator must be fitted at this stage by
insertion into the cold water port.
(The flow regulator is supplied in its own pack).
Fit the flow regulator into the cold port fully
home, with the central O’ ring facing the incoming flow. A small length of
15mm pipe may used to facilitate the installation of this regulator.
9
Remove the outlet elbow from the back plate and replace with the 22mm
outlet connector.
8