Introduction

The product is an exposed bar valve shower complete with fixed and adjustable height shower heads.
The thermostatic valves provide close temperature stability and fail safe protection on appropriate high pressure
systems.

The product is suitable for use on high pressure, combination boiler and boosted gravity systems.

The product is supplied with a 5 year guarantee.

Safety information

This product must be installed by a competent person in accordance with all relevant current Water Supply
Regulations.

THE SHOWER MUST NOT BE USED WITH A HOT WATER SUPPLY TEMPERATURE OVER 65ºC.

The product is designed for domestic use only.

Product specification

These products are suitable for balanced high pressure, combination boiler systems and boosted gravity systems.
Pressure range 1.0* – 10 bar max (static).
* The combination boiler MUST have a minimum rating of 24kW (80,000 Btu) and be of the type fitted with a fully
modulating gas valve.

If in any doubt, please contact the appliance manufacturer before installation commences.

Connections

This product is designed for conventional supplies with HOT on the Left and COLD on the Right as viewed from the
front.

Supply lines must be flushed clear of any debris before installation of the unit. Any debris accumulation in the shower
valve and head may result in damage and poor performance.

Flushing

Some modern fluxes can be extremely corrosive and, if left in contact, will attack the working parts of this unit.
All soldering must be completed and the pipe work thoroughly flushed out in accordance with current Water Supply
Regulations prior to connection of the product.

Filters

To ensure optimum ongoing performance, products are protected by inlet filter assemblies in the internal waterways.
Debris accumulation may result in progressively reduced flow through the showerhead and noisy operation.

Isolating valves

Suitable full way isolation valves must be fitted to both supplies in accordance with current Water Supply Regulations
and our terms of warranty.
Due to their restrictive characteristics, stopcocks and ball type valves that reduce the pipe bore size must not be used
on gravity pumped installations.

Important information

AQ150:Midas  15/9/15  12:15  Page 2

Summary of Contents for AQ150

Page 1: ...AQ150 Thermostatic bar mixer valve with adjustable head Installation guide AQ150 Midas 15 9 15 12 15 Page 1...

Page 2: ...tallation commences Connections This product is designed for conventional supplies with HOT on the Left and COLD on the Right as viewed from the front Supply lines must be flushed clear of any debris...

Page 3: ...the nearest convenient draw off point Account must be taken of pressure drops that may occur when other draw off points are used while the shower is in use A typical layout is shown overleaf Boosted g...

Page 4: ...4 Typical system diagrams Typical pumped system installation Typical gravity system installation 0 5m 1m 1 5m 0 5m 1m 1 5m Water level Water level AQ150 Midas 15 9 15 12 15 Page 4...

Page 5: ...Typical system diagrams continued Typical combination boiler system installation Typical thermal storage unit system installation Typical UVHW system installation 5 AQ150 Midas 15 9 15 12 15 Page 5...

Page 6: ...6 Please note Literature not shown Components may vary Components AQ150 AQ150 Midas 15 9 15 12 15 Page 6...

Page 7: ...rk during the making good process Remove the caps prior to connecting the shower valve In addition to the guide below it is essential that the written instructions overleaf are read and understood and...

Page 8: ...thin bead of mastic if re quired 1 Ensuring the handset cradle is on the left hand side of the rail pass the rail through the handset holder whilst keeping the slider button depressed 2 Fit the forme...

Page 9: ...ct position to accept the fixed riser wall stay support 5 Screw the wall fixing bracket to the wall using the screws provided Place the cover plate over the wall fixing bracket 9 6 Insert the lever of...

Page 10: ...9 Ensuring the hose washers are in the correct position secure the handset to the hose and place into the handset holder The tension of the handset station to the handset holder is factory set Howeve...

Page 11: ...eeds 10 bar install a pressure reducing valve PRV in accordance with the installation guide Airlock in the hot water supply Water temperature swings regularly between hot and cold Flow rate is poor an...

Page 12: ...sa co uk Republic of Ireland Sales enquiries 01 864 3363 Service enquiries 01 844 3212 Please note that calls may be recorded for training and quality purposes The company reserves the right to alter...

Reviews: