3) Install the heating element in a vertical direction, the heating rod must point vertically upwards. The heating element should be carefully
fastened to the radiator or T-piece using a wrench 27.
4) After installation, fill the radiator with heat transfer liquid while venting (in the central heating system) and check the leak tightness of the
connections.
5) Before connecting the heating element to the power supply for the first time, it is necessary to:
- check that there is no flammable material near by the element
- check that neither the radiator nor the heating element is damaged
- make sure that the radiator is filled with heat transfer liquid and the entire heating element rod is immersed in it
- check whether the socket for heating element connection to power corresponds to the plug (rod plug)
5.
THERMOSTAT CONTROL
To switch the heating element on turn the control wheel all the way to the right. When the heating element is switched on the signal diode located
on the thermostat body lights up. To switch the heating element off, turn the wheel to the "0" position.
Picture description:
0 - heating element is switched off
* - + 10 ° C, antifreeze mode
I II III - heating of the element in the range from 5 ° C to 77 ° C
6.
PRODUCT MAINTENANCE
Before cleaning, it is essential to switch the heating element off – pull the cabdle off power supply socket. You can wipe the device with a soft damp
cloth and wipe it dry. Do not use concentrates and abrasive cleaners, as well as disinfectants or organic solvents. You can only switch the heating
element on again after the product has dried completely.
7.
Conditions for claiming the guarantee
a.
The warranty applies exclusively to manufacturing defects.
b.
The warranty does not cover the following damages and defects:
-
Mechanical damage, surface damage caused by the use of chemicals
-
Defects and damage caused by incorrect installation
-
Caused by non-compliance with the instructions for use, transport, storage or maintenance of the heating element
-
Due to use contrary to the general principles of the use of radiators
-
Caused by limescale or improper descaling
-
Due to use on equipment other than that for which the heating element is intended
!!! It is forbidden to fasten the heating element by
turning the part with the thermostat !!!
!!! Improper installation of the heating element in the power supply can endanger life with electric shock!!!
!!! It is forbidden to switch on the heating element unless it is completely immersed in the heat transfer liquid!!!
!!! It is forbidden to soak the body of the heating element and the thermostat in water or use running water
for cleaning!!!