INSTALLING YOUR AQUAGUARD

®

 BLAZE

Make sure that your Aquaguard

®

 Blaze is installed by a trained Eureka 

Forbes Service Technician only.

1.  Input water must be tested for Total Dissolved Solids (TDS).
2.  Install your Aquaguard

®

 Blaze in a dry ventilated place. Keep it away  

     from direct sunlight, heating devices or areas below freezing tempera- 
     ture. Ensure that the height of unit installed on wall is not too high, to  
     avoid splash of hot water.
3.  Ensure that the input water temperature is in the range of 10˚C-40˚C.  
     Avoid connection to a hot water tap as it can damage the filters.
4.  Make sure that the tap water pressure is not exceeding 3.0 kg/cm

2

.

     If the input water pressure is more than 3.0kg/cm

2

, installation of a  

     PRV** (Pressure Reducing Valve) is mandatory.
5.  Flush filter and membrane thoroughly and independently for 3-5 min. to  
     remove fine particles present in the filter.
6.  Make sure that the reject water pipe (Blue colour pipe) is placed lower  
     than the purifier, to avoid stagnation of high TDS reject water in the pipe.
7.  TDS regulator should be adjusted by a trained Eureka Forbes Services  
     technician only to provide healthy water always, as per customer         
     requirement. (For RO+UV+MTDS)

Input Water Quality Usage Limitations:

1.  If the input water iron content is more than 0.3 mg/litre; use of an iron  
     remover** is recommended as a pre-treatment.
2.  If the input water turbidity is more than 5 NTU or comprises colloidal  
     particles, use of a special filter** is required as a pre-filter.
3.  If the input water TDS is more than 1,000 ppm (mg/L) or input water   
     hardness is more than 300 ppm (mg/L), use of a Membrane life  

 

     enhancer** is recommended.
4.  Do not install the water purifier if the TDS is more than that prescribed  
     in the technical specifications.
**Available at an extra cost.

PURIFICATION PROCESS OF AQUAGUARD

®

BLAZE RO+UV+MTDS 

TECHNICAL SPECIFICATIONS* 

BLAZE RO+UV+MTDS 

Copper has antimicrobial, antioxidant, and 

anti-inflammatory properties that help to support 

healthy metabolism. It also helps to provide the 

body with energy and is much needed for growth 

and development. The activated carbon removes 

organic components and polishes the water, 

giving it a sparkling look, making it pure and 

great to taste.

The Multi-Stage Purification Process of Aquaguard

®

 Blaze Hot & Ambient.

i-Filter™

Multi-layered Polypropylene 

Roving Wound Cartridge

Removes fine suspended particles such as dust, 

dirt mud and sand from water.

Chemi-Block 

(with built-in 

Particle Trap Filter™)

Dust-free Bacteriostatic 

Activated Carbon Block

Reduces excess chlorine and organic impurities. 

Also adsorbs bad taste and odour from the water.

Mineral 

Guard™

*+

Micro Controller-based 

Electronic Impulse 

Producer

Prevents the deposition of dissolved minerals like 

Ca and Mg on the Quartz Tube of UV chamber, 

thus, enhancing the availability of minerals in water.

Membrane Life 

Enhancer***

Special Anti-scalant 

Media

Prevents scaling of dissolved salts on the surface

of the membrane, thereby, enhancing the

membrane life and performance.

Reverse 

Osmosis 

Membrane

Thin Film Composite 

(TFC) Reverse Osmosis

 Membrane

Reduces TDS, hardness, pesticides and heavy 

metals like arsenic, lead and mercury. Eliminates 

micro-organisms like bacteria, viruses, protozoa 

and cysts.

UV e-boiling

Germicidal UV Lamp

Active 

Copper™ 

Cartridge

+

^^

Bacteriostatic Taste 

Enhancer with Active

Copper™ Technology

UV disinfects the water by eliminating waterborne 

disease-causing bacteria, viruses and protozoa, 

thereby, making it safe to drink.

MTDS 

Regulator

Mechanical System

Adjusts the TDS of purified water to provide 

healthy water always.

Aquaguard

®

 blaze Hot & Ambient

Model

2

Dimension (W X D X H)  

330 mm X 440 mm X 490 mm

Net Weight

13 KG (Approx.)

3

Purification Technology

RO+UV+MTDS Regulator
3.9 litres (Ambient water tank - 3.1 litres & Hot 

water tank - 0.8 litre)

4

Tank Capacity 

i-Filter™, Chemi-Block, Mineral Guard™, 

Reverse Osmosis Cartridge, UV e-boiling, 

Active Copper™ Cartridge, MTDS Regulator

5

6

Standard Filtration 

supplied   

1

1

Power Rating

595 Watts (Heater - 550 Watts)

RO Membrane Rating

75 GDP

1

Iron Content (Max.)                           

0.3 mg/L

2

Total Dissolved Solids 

(TDS) (max.) 

Up to 2,000 mg/L

++

5

Total Hardness (max.) 

600 mg/L

6

Chlorine Content 

(Max.)                           

0.2 mg/L

3

Input Water Turbidity 

(Max.)

5 NTU

4

Input Water Pressure 

Range**

Up to 3.0 kg/cm²

1

UV Lamp

11 Watts

3

UV Lamp Life

8,000 burning hours (as per UV lamp manufacturer spec.)

4

Operating Voltage Range

150 VAC to 280 VAC, 50 Hz

5

Power Supply

Internal AC/DC Adaptor 24V DC / 2.5 A, Heater Input - 

230V AC, 50 Hz.

2

ELECTRICAL SPECIFICATIONS

RECOMMENDED INPUT WATER PARAMETERS

PRODUCT SPECIFICATION

*Technical Specifications are subject to change without prior notice. 

Note: The performance data presented in the table is applicable under standard laboratory conditions

#

. Actual performance may vary 

depending on the input water quality, water pressure and condition of filters. If the pressure is higher than the maximum specified, use of a 
pressure reducing valve is mandatory. The above accessories are available with our company at an additional cost. 

++

If the input water  TDS is more than 1,000 ppm (mg/L) or input water hardness is more than 300 ppm (mg/L), use of a Membrane life enhancer 

Performance data sheets are available with Eureka Forbes Technical Documentation Centre.

Warranty void if the product is not installed as per recommendations.

#

Standard Test Conditions:

Feed Water Quality: TDS Max: 1,000 mg/litres with NaCl Pressure: 1.0kg/cm

2

, Turbidity: Max.1 NTU, Temperature: 25°C, Chlorine: below 

0.2 mg/litres, Iron: below 0.3 mg/litres  Life: 6,000

#

 Litres. Pressure on membrane: 75psi. Product Recovery @ 25%.

#

Actual performance may vary based on the input water conditions - TDS, Hardness, Pressure, Temperature & pH. Standard test Condition 

are valid for online water supply installation. In suction mode, the product performance may be lower than the claims.

LED INDICATION CHART FOR 

AQUAGUARD

®

 BLAZE RO+UV+MTDS 

Aquaguard

®

 BLAZE Hot & Ambient

NOTE: THIS IS A SCHEMATIC ILLUSTRATION OF THE PRODUCT TO GIVE A VISUAL SCHEME OF WORKING OF PRODUCT.
THIS IS NOT AN ACTUAL ENGINEERING DRAWING OF THE PRODUCT.

e-boiling

HERE'S HOW YOUR AQUAGUARD

®

BLAZE RO+UV+MTDS WORKS

MEMBRANE LIFE ENHANCER

***Not a part of the product, Membrane life enhancer is recommended if the input water TDS is more than 

1,000 ppm (mg/L) or input water hardness is more than 300 ppm (mg/L). Available at extra cost.

Membrane life enhancer is 

recommended to be installed 

if the TDS  is above 1000 ppm or 

hardness above 300 ppm

is recommended. 

,

Summary of Contents for ACTIVE COPPER MINERAL GUARD BLAZE HOT+SS

Page 1: ...at s more you can trust your Aquaguard Blaze to also remove harmful lead pesticides and chemicals from your water All to ensure that your family stays safe and healthy BLAZE Hot Ambient An aesthetic design and metallic cabinet finish ensures that Aquaguard Blaze Hot Ambient complements every environment be it the office or home Active Copper Cartridge Copper has antimicrobial antioxidant and anti ...

Page 2: ...ike arsenic lead and mercury Eliminates micro organisms like bacteria viruses protozoa and cysts UV e boiling Germicidal UV Lamp Active Copper Cartridge Bacteriostatic Taste Enhancer with Active Copper Technology UV disinfects the water by eliminating waterborne disease causing bacteria viruses and protozoa thereby making it safe to drink MTDS Regulator Mechanical System Adjusts the TDS of purifie...

Page 3: ...n the table is applicable under standard laboratory conditions Actual performance may vary depending on the input water quality water pressure and condition of filters Input water quality pressure TDS are important determinants of recovery rate and rejection Warranty void if product not installed as per recommendations If the input water TDS is more than 1 000 ppm mg L or input water hardness is m...

Page 4: ...y them for which the Customer will deposit the goods at its own expense if so required by the Company with the Company s Office Service Centre along with the original invoice in the city where they are sold 3 The Inspection and Test Report of the company s office service centre will be final and binding under the warranty for determining defects repairs alterations required or carried out or certi...

Page 5: ...nt and under no circumstances exceed the price paid by the customer to the company for the goods stated in the invoice General For the purpose of this warranty the following expressions shall have the following meanings respectively 1 The Goods shall mean the goods described in the Order Form 2 The Customer shall mean the original purchaser of goods from the company 3 The Company shall mean EUREKA...

Reviews: