operation,  unplug  the  device  and  plug  in  again.  For  E002,  when  the  reason  causing  this  error 

relieved, the frequency inverter will resume operation automatically. 

Item 

Code 

Description 

Analysis 

E001 

Input voltage exceeds upper limit of operation range 

Not faulty 

E002 

Input voltage exceeds lower limit of operation range 

Not faulty 

E003 

Output over current   

Not faulty 

E004 

Overload or short circuit 

Not faulty 

 

E101 

Inverter module overheat   

Could be faulty 

E102 

Master board error   

Could be faulty 

AL01 

Auto speed reduction against over heat 

Could be faulty 

 

E201 

Circuit error   

Faulty 

E202 

Master board EEPROM reading failure   

Faulty 

10 

E203 

RTC time reading error   

Faulty 

11 

E204 

RTC backup battery low capacity error   

Faulty 

12 

E205 

EEPROM reading error   

Faulty 

13 

E206 

Communication data failure   

Faulty 

14 

E207 

Communication connection failure   

Faulty 

 

 

 

 

Manufacturer will be held no liability for any consequences resulting from inappropriate, incorrect 

installation, or mismatching of the product to pool pumps that does not compatible. 

 

Manufacturer reserves the right to change the specification of the product or its performance or 

the contents of the User Guide without notice in case of technical upgrade. 

 

11. WEEE LEGISLATION 

When disposing the product, please hand it over to a designated collection

 

point for the recycling 

of waste electrical and electronic equipment. 

 

 

The separate collection and recycling of waste equipment at the time of 

disposal  will  help  ensure  that  it  is  recycled  in  a  manner  that  protects 

human health and the environment.   

 

For more information about where you can drop off your waste for 

10. EXEMPTION   

Summary of Contents for iSAVER 1100

Page 1: ...FREQUENCY INVERTER INSTALLATION USER GUIDE Thank you for purchasing our frequency inverter Please read the manual carefully before installing or using it and keep it for future reference after installation ...

Page 2: ......

Page 3: ...echnical Data 3 6 Installing The Frequency Inverter 3 7 Connecting Frequency Inverter To Pool Pump 4 8 Setting And Operation Instruction 5 9 Protection Error Code 7 10 Exemption 8 11 WEEE Legislation 8 IMPORTANT Please read this manual carefully before installation and keep it for future reference after installation ...

Page 4: ...evice can ONLY be used with domestic single speed swimming pool pumps with permanent split capacitor motor See below please a typical single speed swimming pool pump motor Fig 1 2 4 It is NOT compatible with a Capacitor start asynchronous motors with centrifugal switch gear b Pool pump motors with start relays or switch c Series or DC motors d Pool pump motors with faults in their rotors or capaci...

Page 5: ...here air flow is limited as this may cause overheat or potentially cause damage 4 BEFORE INSTALLATION 4 1 Check for damage in transit upon receipt of the frequency inverter If it is found to be damaged Do NOT PROCEED with installation and contact your supplier 4 2 If the power cord is damaged DO NOT PROCEED with installation Contact your supplier for further instruction or replacement 4 3 Do not u...

Page 6: ... phase AC Input voltage 220 240V 220 240V Input Frequency 50Hz 50Hz Output power 1100 W 1 5 horsepower 2200 W 3 horsepower Pump type SINGLE SPEED 1 phase SINGLE SPEED 1 phase Max current 6A 12A Speed range 1200 2900 rpm 1200 2900 rpm Cooling By air By air Net Dimension L H W 155 195 130 mm 155 195 130 mm Gross Net Weight 3 6 3 1 Kg 3 6 3 1 Kg The manufacturer has the right to modify technical data...

Page 7: ...g for installation connect wires as shown in Fig 4 please Fig 4 This device weighs 3 6 kg it is very important that it is held securely to a firm flat surface such as a concrete wall 7 CONNECTING FREQUENCY INVERTER TO POOL PUMP Only 1 pump can be connected to the frequency inverter Please do not connect any other appliance to the output Failure to comply with this may result in damage to the devic...

Page 8: ...n just follow the operation guide Do not touch the heat sink while the frequency inverter is in operation or until at least 30 mins after it has been switched off Keep it out of reach 8 SETTING AND OPERATION INSTRUCTION 8 1 Control panel 8 2 Mode setting 8 2 1 The frequency inverter has 3 modes each with a speed range and its default speed as follows Mode Speed range Default speed Winter 1200 1650...

Page 9: ...3 Timer setting If you want your pump to run at different period of time or speed to take advantage of different electricity tariffs you can set up to 4 timers in 24hours Follow this sequence to complete timer setting by pressing Current time Timer ON Timer OFF Speed Press to return to last setting Step1 Press to enter timer setting interface Step2 Use or to set current time Timer ON Timer OFF Pre...

Page 10: ...of frequency inverter can be controlled from third party pool controls using potential free contacts See Fig 5 for connection Fig 5 Under OFF mode connect terminal 4 and 7 to enable external control disconnect these two to terminate external control Note Even if it s working via external control Press on the frequency inverter can stop the frequency inverter Do not apply voltage to these inputs 8 ...

Page 11: ...apacity error Faulty 12 E205 EEPROM reading error Faulty 13 E206 Communication data failure Faulty 14 E207 Communication connection failure Faulty Manufacturer will be held no liability for any consequences resulting from inappropriate incorrect installation or mismatching of the product to pool pumps that does not compatible Manufacturer reserves the right to change the specification of the produ...

Page 12: ...9 recycling please contact your local authority ...

Page 13: ...A003 ...

Reviews: