Aquagarden Energy Saver Pond Pumps
are centrifugal pumps with a magnetic impeller
movement driven by a watertight digitally controlled motor. They only require periodic cleaning of the
pre-filter cage, impeller and impeller chamber.
Opening the cage/impeller maintenance
To remove the cage:
PUMP MAINTENANCE
8
To access the impeller:
With the cage open, unscrew the four bolts (ringed on the left diagram), and remove the impeller cover.
With the cover removed, locate the small open area ringed in the right hand diagram, insert a wide
flathead screw driver and gently prise the impeller up until it is loose. Once it is loose remove by hand.
Wash the cage, impeller and impeller chamber with plenty of fresh water and reassemble.
Winter Storage:
These pumps can be run in the pond during the winter, but care should be taken to ensure they are fully
immersed and cannot freeze solid. If the pump is not used during the winter, remove from the pond and
allow it to drain, then store in a frost free location (shed or garage) until the spring.
Insert tool, e.g. a flat bladed
screwdriver, and lever the clasp to
release. Once open, lift the front
section of the cage away from the
pump. From here, the motor can be
slid out from the rear section of the
cage.
When putting the pump back
together, the motor will only fit in one
direction, this can be checked by
lining up the outlet nozzle and the
cable exit on the rear cage section
(ringed in the diagram to the left)
Warning -
ensure the pump is turned off at the mains power supply before any
maintenance is undertaken
EN