UltraSieve Installation instructions

 

 

 

Please read these instructions before you start installing.  

 

If you have some questions after reading this manual, please contact your UltraSieve dealer before you start installing to 
prevent mistakes. 
 
The UltraSieve can be installed in 2 ways:  
 
1.  Gravity (pond fed), equal to the water level in a direct connection with the bottom drain (and/or skimmer)  
2.  Pump fed, above the ground with a free flow back to the pond.  
 
Below you see a schematic drawing of a possible gravity installation  

Slide valve between pond and UltraSieve 

Pond Water Level 

Bottom drain 
 

NOTE

: Make sure the edge of the UltraSieve is 1 cm higher 

than the maximum water level 

 

Make sure the UltraSieve is on an equal, level, underground. 

The upper edge of the UltraSieve must be 1 cm above the 

maximum water level

. Between the bottom drain and the UltraSieve we strongly advise you to use a slide valve to separate 

the UltraSieve from the pond when necessary. The inlet of the UltraSieve is made of 110mm Polypropylene pipe so you can 
use a PVC push fit fitting. Since the UltraSieve is made of Polypropylene you cannot make glue connections. The UltraSieve 
has 2 inlets of 110 mm of which one is closed. If you want to use both inlets you have to cut off the end of the closed one.  

Note: Do not install the UltraSieve directly in the soil! Make sure there is always enough room around the unit. When 
there is pressure on the unit it will not work properly.

 

110mm inlets 
(use push fit fittings) 

 

Outlet: PP 2” male 

threaded - 

PVC fitting 2” fem. 

threaded/63mm 

solvent

Pump connection 

 

The pump outlet is made of a 2” PP male threaded connection. The UltraSieve is 
supplied with a PVC fitting 2” fem. thread x 63mm solvent. Please use Teflon tape or 
Loctite 5331 for the threaded connection. The maximum flow of the UltraSieve is about 

30

m³ per hour. 

 

Pond 

pump 
 

Filter 

Slide valve to flush the bottom drain direct to 
waste without going to the filter. 

 

In case the pump sucks in 
air, because of the falling 
water near the pump exit, 
you can put the supplied 
piece (±45 cm) of pipe 
Ø50mm in the pump exit with 
some Teflon tape. Then, the 
pump will no longer take in 
the water from the “turbulent" 
part (A), but from the very 
“quiet” part underneath the 
float system (B).  

 
 