16
Contact Your Sales Representative for Further Assistance.
6. Fog Slowly Decreases
If fog output gradually decreases over time, sediment is slowly clogging the flowmeter's
needle valve. Try operating at a higher output or cleaning the inline strainer (Part #71). If the
problem persists, a smaller size flowmeter may be required. Flowmeters perform best when
set half way up the scale or higher.
7. Fan Motor Becomes Excessively Hot
The main fan motor normally becomes very hot to the touch. However, if it gets so hot that it
begins to smell or smoke or the power cord becomes hot, discontinue operation and consult
an electrician to properly evaluate the problem.
8. Electrical Breaker Tripping
If the electrical breaker trips off, there is an overload in the system and there may be a
serious motor problem. Turn off all other devices connected to the same circuit. If the
breaker continues to trip, the motor is probably in need of repair. Consult an electrician
for evaluation.
9. Fan and/or Motor Vibration
A.)
If the fan unit begins vibrating severely, first be sure the blade assembly is fully engaged
and securely tightened on the motor shaft. Next, inspect the blade assembly, particularly
the ends of the blades. Look for wear or cracks - replace as necessary. Look for deposits
of calcium or minerals - clean and remove mineral deposits and/or calcium.
B.)
If the vibration seems to be coming from the motor, first check that the motor mounting
hardware is securely tightened. If hardware is secure, remove the blade assembly and
operate the motor without the blade. If vibration continues, the motor has a serious
mechanical problem and probably needs to be replaced.
10. Liquid Spilling From Fan Housing
If liquid builds up inside the housing, the drain tube is clogged. Clean debris from around
the drain inside the housing and flush drain tube.
11. Plumbing Leaks
Un-thread fittings and clean both the male and female threads. Apply new thread tape
(approximately 2-3 wraps) and reconnect. If a tube fitting is leaking, tighten the cap - no
more than 1 turn past finger tightened. If the leak persists, replace the tube fitting insert.
T
ROUBLESHOOTING
(
CONT
.)
BEFORE INSPECTION AND /OR SERVICE
DISCONNECT AND LOCK OUT POWER SOURCE.
WARNING