INSTRUCTIONS
SET UP
1. Remove chiller and accessories from box. Examine for damages.
2. Place chiller on a stable, flat, even surface in an area that will receive good ventilation and
allow for air flow. Allow at least 2’ around front, back and side of chiller for proper
ventilation.
3. Do not store chiller in a closed location that does not receive air flow such as a closet or
cabinet. Chiller must receive air flow. (A fan may be required to draw warm air away from
chiller). Keep away from heat sources to maintain optimal temperature. Maximum operating
temperature for this chiller is 95
˚ Fahrenheit.
4. Assemble inlet and outlet plumbing fittings and connect to the chiller. Chiller is labeled near
fittings with IN and OUT for proper installation. Make sure seal rings are properly positioned.
5. Connect external flexible hoses to the inlet and outlet, tighten the metal screw clamps so
that hoses do not disconnect while chiller is in use.
6. Only use a pump that provides between 420 to 720 gallons per hour.
Before turning chiller on:
7. Once all connections are made, circulate water through chiller for 30 minutes before turning
the unit on. Check all connections for water leakage and/or obstruction. Check pump is
operational and unblocked.
2.)
3.)
4.)
5.)