2737 24th Street North • St. Petersburg, FL 33713 • 727.823.5642 • 800.786.7751 • fax 727.821.7471
#
4
0
5
4
A
T
1
5
5
0
8
0
5
V
1
aquacal.com
BTUs
Compressor
Efficiency
Coefficient of Performance
Kilowatt Input
E
l
ec
t
ric
al
V
olta
g
e
/Hz/
P
h
a
s
e
M
inimum Circuit
A
mpacit
y
R
ecommen
d
e
d/M
a
x
imum
F
u
s
e
S
i
z
e
W
at
er
F
l
o
w
M
inimum
/M
a
x
imum
Ph
ysic
al
Sh
ippin
g
W
ei
gh
t
(
l
b
s
)
S
i
z
e
(
len
g
t
hx
wi
d
t
hxh
ei
gh
t
)
127,000
S
croll
6.3
5.9
208v-230v
/
60
hz/
1
p
h
37
40
/
70
20-70
g
pm
430
36”
x
32”
x
43”
Contact AquaCal for your free
heat cost and sizing analysis.
HIGH TEST POINT TEMPERATURE
LOW TEST POINT TEMPERATURE
Rated and certified in accordance with ASHREA standard 146-1998 and PHPMA Addendum test procedure.
All other ratings are outside of the scope of the PHPMA Heat Pump pool heater certification program.
90˚ 80˚ 70˚ 60˚ 50˚ 40˚
BTUs
A
T
155
H
E
A
T
ING
BTU
RA
T
ING
P
E
R HO
U
R
65,000
75,000
85,000
95,000
110,000
120,000
130,000
70,000
80,000
90,000
100,000
115,000
125,000
63% RELATIVE HUMIDITY / 80˚ WATER TEMPERATURE
80% RELATIVE HUMIDITY / 80˚ WATER TEMPERATURE
A
T
155
A
E
RO
TE
MP
155
W
HISP
E
R Q
U
I
ET
F
AN
•
ma
x
imum air flow
C
L
E
AR
LO
C
KING
C
OV
E
R
•
tamper proof
s
ettin
gs
C
ORROSION
PROO
F
C
A
B
IN
ET
•
ru
s
t proof
•
fa
d
e proof
•
crac
k-
re
s
i
s
tant
O
FF
-S
ET
PL
U
M
B
ING
•
ea
sy
in
s
tallation
E
ASY
A
CCE
SS
PAN
E
L
•
ea
sy
in
s
tallation
•
ea
sy
to
s
er
v
ice
AQ
U
A
T
OP
•
protect
s
component
s
from lea
v
e
s
an
d d
e
b
ri
s
C
OMPR
E
SSOR
•
s
tate of t
h
e art tec
h
nolo
gy
•
h
i
gh
e
s
t efficienc
y
• q
uiete
s
t operation
•
un
s
urpa
ss
e
d
relia
b
ilit
y
•
s
uperior
d
ura
b
ilit
y
D
U
AL
RO
W
C
OA
TE
D
E
VAPORA
T
OR
C
OIL
•
more
h
eatin
g
power
•
a
dd
e
d
protection
from t
h
e element
s
T
I
T
ANI
U
M
H
E
A
T E
X
C
HANG
E
R
•
patente
d
counter
-
flow
water mana
g
ement
sys
tem
•
h
eat
s
water fa
s
ter an
d
more efficientl
y
•
imper
v
iou
s
to c
h
emical
corro
s
ion
•
d
ura
b
ilit
y
wit
h
out
s
acrificin
g
performance
•
limite
d
lifetime warrant
y
AQ
U
A
C
AL'S
T
O
T
AL
Q
U
ALI
T
Y
C
OMMI
T
M
E
N
T
S
ince
1981,
A
q
uaCal
h
a
s
b
een
s
ettin
g
t
h
e
s
tan
d
ar
d
for e
x
cellence
,
d
eli
v
erin
g
t
h
e
b
e
s
t
s
wimmin
g
pool
/s
pa
h
eat pump
s
in t
h
e in
d
u
s
tr
y
.
CE
R
T
I
F
I
E
D AQ
U
A
C
AL
S
E
RVI
CE
•
factor
y
traine
d
•
HVA
C licen
s
e
d
•
CP
O
certifie
d
•
protect
s y
our in
v
e
s
tment
•
s
ati
s
faction
g
uarantee
d
MI
C
ROPRO
CE
SSOR
C
ON
T
ROLL
E
D
W
I
T
H DIGI
T
AL
DISPLAY
•
accurate an
d
ea
sy
to rea
d
•
time an
d
temperature
s
ettin
gs
•
on
-b
oar
d s
elf
d
ia
g
no
s
tic
s
AVAILA
B
L
E
IN
2
C
OLORS
• b
lac
k
•
creme