aquabrass.com
last revision: 11/14/2019
5
Xround X75N83
floormount lavatory faucet
robinet de lavabo au sol
Fig.5
2
4
3
1
4
Fig.4
1
2
3
Fig.6
1
Cartridge replacement
Remplacement de
la cartouche
To clean the aerator, remove the aera-
tor (1) from the spout. Then soak it in a
vinegar and water solution to remove
lime build-up. Once parts have been
cleaned, reinsert the aerator.
Start by shutting off water supply lines
and then turn the faucet on to drain it.
To replace the cartridge (4), remove
the set screws (1), take out the handle
(2) and unscrew the dome cap (3).
Replace the cartridge (4) with the
new one and reassemble by reversing
steps.
Fixing to the floor
Fixation au sol
Before install the faucet, remove the
plastic plugs (3).
Insert the hot and cold hoses on
rough, fix the faucet on floor with three
screw (2) (not supplied) and place the
decorative flange (1)
Enlever les bouchons en plastique (3),
insérer les tuyaux d’eau chaude et
froide à la valve. Fixer le robinet sur
le plancher avec les trois vis (2) (pas
fournies) et placer la bride décorative.
Pour nettoyer l’aérateur, dévisser
l’aérateur (1). Ensuite, tremper
l’aérateur dans un mélange de vinaigre
et d’eau, pour retirer le calcaire qui
pourrait s’y être accumulé. Une fois les
pièces nettoyées, replacer l’aérateur.
Couper l’alimentation d’eau et ouvrir le
robinet pour vider l’eau résiduelle.
Pour remplacer la cartouche (4),
enlever la vis de réglage (1), retirer la
poignée (2) et dévisser le capuchon
en dôme (3). Remplacer la cartouche
(4) avec la nouvelle et remonter en
inversant les étapes.
Aerator Cleaning
Nettoyage de l’aérateur
Summary of Contents for Xround ABFBX75N83110