DESCRIPTION

OVERHEAD - SMART 200 - NO AIR CHROME

OVERHEAD X JET 200 CHROME

2.5mm SEALING WASHER FOR SHOWER HOSE - PACK 5

TOP CONNECTER FOR SHOWER ARM

NON ROTATION SHOWER ARM AND HEATER CONNECTOR FOR AQ5517 / AQ5611

NON ROTATION SHOWER ARM AND HEATER CONNECTOR FOR AQ5518 / AQ5612

FREE FIX WALL BRACKET SET CW FIXINGS

WALL BRACKET PACK FOR SLIDE BAR X 2 ( FREE FIX ) CHROME

SHOWER TUBE 600 X 25MM WITH END CAPS CHROME

FRONT LOADING SLIDER MECHANISM CHROME

SMOOTH 1.5M PVC  SHINY HOSE WITH ABS CONICAL  NUTS CHROME

HAND SHOWER BELLA 3F - NO AIR CHROME

HAND SHOWER X JET 1F CHROME

HEATER COVER COMPLETE 1 HANDLE WHITE

HEATER COVER COMPLETE 1 HANDLE GLOSS BLACK

HEATER COVER COMPLETE 1 HANDLE FULL CHROME

HEATER COVER COMPLETE 1 HANDLE WHITE

HEATER COVER COMPLETE 1 HANDLE GLOSS BLACK

HEATER COVER COMPLETE 1 HANDLE FULL CHROME

SCREW FIXATION PACK FOR HEATER

THERMAL CUT OFF DEVICE

DIVERTOR VALVE ASSEMBLY FOR AQ5517 AND AQ5518

ELECTRICAL TERMINAL BLOCK

POWER SWITCH ASSEMBLY

GRILLON HEATER TANK ASSEMBLY

VOLUME CONTROL VALVE ASSEMBLY COMPLETE

PRESSURE RELIEF VALVE TUBE

FILTER

SPARE PART DETAILS FOR AQUAMAX WATER HEATERS

Summary of Contents for AQUAS AQUAMAX FULL PRO FLEX SMART 9.5KW

Page 1: ...re taken during the installation will provide a long trouble free life from your shower INSTRUCTION GUIDE AND USER MANUAL INSTANTANEOUS ELECTRIC WATER HEATER MANUAL AQUAMAX FULL PRO FLEX X JET 9 5KW AQUAMAX TOP SMART 9 5 KW AQUAMAX FULL PRO FLEX SMART 9 5KW AQUAMAX PRO X JET 9 5 KW By AQUABELLA SHOWER CO LTD ...

Page 2: ...PLEASE READ THIS IMPORTANT SAFETY INFORMATION ...

Page 3: ...IMPORTANT GENERAL ADVICE TO SHOWER UNIT USERS ...

Page 4: ...BATHROOM FLOOR CEILING JOISTS SPILL OVER LEVEL HOSE RETAINING RING DOUBLE POLE SWITCH CEILING MOUNTED GENERAL LAYOUT OF A SHOWER INSTALLATION ...

Page 5: ...AQUAMAX FULL PRO FLEX 9 5 KW RECOMMENDED INSTALLATION DIMENSIONS FOR ALL MODELS AQUAMAX FULL PRO FLEX AQUAMAX TOP AND AQUAMAX PRO ...

Page 6: ...FREE FIX WALL BRACKET SET CW FIXINGS WALL BRACKET PACK FOR SLIDE BAR X 2 FREE FIX CHROME SHOWER TUBE 600 X 25MM WITH END CAPS CHROME FRONT LOADING SLIDER MECHANISM CHROME SMOOTH 1 5M PVC SHINY HOSE WITH ABS CONICAL NUTS CHROME HAND SHOWER BELLA 3F NO AIR CHROME HAND SHOWER X JET 1F CHROME HEATER COVER COMPLETE 1 HANDLE WHITE HEATER COVER COMPLETE 1 HANDLE GLOSS BLACK HEATER COVER COMPLETE 1 HANDLE...

Page 7: ...AQUAMAX FULL PRO FLEX 9 5 KW MANUAL WATER HEATERS 1B 3B 2 3A 11 1A 4 4 2 9A 11 12 11 16 18 17 10 10 14 13 15 5 5 5 11 4 4 4 4 2 2 8 6 6 6 7 5 5 5 5 5 2 3 9B ...

Page 8: ...AQUAMAX TOP 9 5 KW MANUAL WATER HEATERS 10 10 11 1A 4 4 3A 2 11 12 11 16 18 17 14 15 11 4 4 4 4 2 2 3 1B 3B 2 ...

Page 9: ...11 9A 11 12 11 16 18 17 10 10 14 13 15 5 5 5 11 2 2 8 6 6 6 7 5 5 5 5 5 AQUAMAX PRO 9 5 KW MANUAL WATER HEATERS 9B ...

Page 10: ...AQUAMAX FULL PRO FLEX AND AQUAMAX TOP ASSEMBLY OF UPPER SHOWERING COMPONENTS 4 4 4 3A 2 2 3 4 ...

Page 11: ...AQUAMAX FULL PRO FLEX AND AQUAMAX PRO 9A 5 5 5 2 8 6 6 6 7 5 5 5 5 5 ASSEMBLY OF UPPER SHOWERING COMPONENTS 1A 2 ...

Page 12: ...Top fixing position 130 mm 400 mm arrow depict water and electrical entry points PLUMBLING CONNECTIONS ...

Page 13: ...PLUMBLING CONNECTIONS ...

Page 14: ...ELECTRICAL CONNECTIONS ...

Page 15: ...ELECTRICAL WIRING ...

Page 16: ...ivertor handle are in the 12 O clock position before fitting the cover Turn the stabilizer valve spindle and volume handle fully clockwise until resistance is felt Fit cover into position and re fit cover fixation screws Stabilizer valve Divertor spindle When fitting the cover it is important to align the divertor spindle and volume control spindle inside the heater ...

Page 17: ...n on the water and electricity before fitting the front cover Push the on off button to check water flow and if there is any leakage inside the heater or at any shower connection 1 Before installation rotate the volume control handle clockwise until resistance is felt Connect the water and electricity supply IMPORTANT NOTE FOR THE INSTALLER WARNING failure to remove that part after commissioning w...

Page 18: ...ount of hot water In the summer months the ECO button can be activated which will reduce the KW output down to 5 0 KW 6 To turn off the shower unit press the ON OFF button IMPORTANT NOTES The Higher the flow the temperature will decrease The Lower the flow the temperature will increase It is recommended that you start the shower with the volume handle in the fully anti clockwise cold position as t...

Page 19: ...ANING THE FILTER STEP 1 Remove front cover assembly loosen these two screws the decor cover can be removed STEP 2 STEP 3 Use flat head screw driver to remove filter clean it and refit Clean the filter and refit FILTER ...

Page 20: ...nded heaters are supplied by Aquabella Shower Co Ltd in Thailand For information or service assistance please contact the installer or the local UK distributor from where the heater was purchased Ai0051 1 To break away scale deposite on a daily basis simply rub your thumb over the surface whilst the shower is running SHOWERHEAD CLEANING INSTRUCTIONS ...

Reviews: