background image

 

 

05/02/2021 Rev.1

 

18

 

 

IT 

Codice 

Modello  Descrizione 

Q.tà 

ADSP9300030 

 

CASSA HC999 ARNITE NERA D31 

ADSP6000I12 

1A-2A 

CORPO POMPA 4-20/10-10 PP-GL-DT INCOMPLETO - HC999   

ADSP6000I17 

3A 

CORPO POMPA 20-05 PP-GL-VT INCOMPLETO - HC999 

ADSP6000096 

1A - 2A  MAGNETE COMPLETO D90 VERS.1 230V - SILENZIOSO 

ADSP6000166 

3A 

MAGNETE COMPLETO D90 VERS.2-3 230V - SILENZIOSO 

ADSP9300040 

 

SKD HC999 PI-MA-CL (EL202+EL202A) 90-260V    

ADSP9300031 

 

GUARNIZIONE HC999 IN GOMMA NBR SP.1,5MM 

ADSP9300023 

 

COPERCHIO HC 999 ARNITE NERA 

ADSP9300027 

 

ETICHETTA POLICARBONATO HC999 NEUTRA 

ADSP9300026 

 

COPERCHIO FRONTALE TRASPARENTE HC999  

ADSP9200001 

1A - 2A  DIAFRAMMA PTFE DYNEON 1614 1-14L HC897 M12X1 

ADSP6000891 

3A 

DIAFRAMMA - MEMBRANA IN PTFE D.60X19 - PER 20L-5BAR HC999 

10  ADSP6000767 

 

VITE M 3,5 X 19 UNI 6954 (AF-TCTC) INOX A2 

11  ADSP6000701 

 

RONDELLA PIANA D. 5 - UNI 6592 INOX A2 

12  ADSP9000016 

 

VITE M 5 X 30 UNI 5931 (TCEI) INOX A2 

13  ADSP9300041 

 

COVER IN PP-NERO PER CORPO POMPA HC999 

14  ADSP9000003 

 

TARGHETTA NERA CON LOGO AQUA PER CORPO POMPA 1-14LT HC897 

15  ADSP5007072 

 

OR "R1" NBR - 2.60X1.90 

16  ADSP6000708 

 

VITE M 4 X 8 UNI 7688 (AF-TSTC) INOX A2 

17  ADSP9000035 

 

GUARNIZIONE COPERCHIETTO ALIMENTAZIONE HC999 GOMMA NBR 

18  ADSP6000503 

 

INTERRUTTORE BIPOLARE 250V A BILICO SIMBOLO 1/0 CON PROTEZIONE  
IN GOMMA 

19  ADSP9300025 

 

COPERCHIO CONNETTORI HC999 ARNITE NERA 

20  ADSP6000887 

 

VITE M 3,5 X 22 UNI 6954 (AF-TCTC) INOX A2 

21  ADSP6000424 

 

PRESSACAVO PASSO PG7 - 1900.07 - NERO 

22  ADSP6000581 

 

PRES DADO PG9 NERO (vn) 

23  ADSP6000836 

 

CONNETTORE MASCHIO 4 VIE G4A5M CABLATO LIVELLO PANDUIT 2 VIE 

24  ADSP6000749 

 

VITE M 2,9 X 9,5 UNI 6954 (AF-TCTC) INOX A2 

25  ADBAS100 

 

BASE SOSTEGNO POMPA HC100 NERA 

26 

ADSP9000014 

1A - 2A  ATTACCO TUBO 4X6 GHIERA 1/2" PP 

ADSP6000134P 

3A 

ATTACCO TUBO 6X9 RACCORDO 3/8" PVDF 

27 

ADSP9000013 

1A - 2A  ADATTATORE TUBO 4X6 GHIERA 1/2" PP 

ADSP6001001 

3A 

ADATTATORE TUBO 6X8 GHIERA 1/2" PVC 

28  ADSP9000012 

 

GHIERA 1/2" PP PER VALVOLA A SFERA NERA 

29  ADSP9000019 

 

RONDELLA D16X0.5 PE NAT 

30  ADSP6300910 

3A 

FLANGIA PISTONE PORTATE MEDIE D.43 - SIL. 

31 

ADSP5007200 

1A - 2A  OR - RIF.  3143 - VITON NERO 

ADSP5007214 

3A 

OR - RIF.  3212 - VITON NERO 

32 

ADSP5007133 

1A - 2A  OR - RIF. ORM0380-20 - VITON NERO 

ADSP5007119 

3A 

OR - RIF.  2212 - VITON NERO 

 

 

SERIE HC 899-999  

Summary of Contents for HC899 Series

Page 1: ...05 02 2021 Rev 1 1 OPERATING AND MAINTENANCE INSTRUCTIONS HC899 HC 899 ...

Page 2: ...05 02 2021 Rev 1 2 ...

Page 3: ... supplied 7 3 3 Electrical characteristics 7 3 4 Electrical connections 7 3 5 Hydraulic connections 8 3 6 Operations 9 4 0 MAINTENANCE 9 4 1 General maintenance comments 9 4 2 Periodic maintenance 10 4 3 Basic maintenance procedures 10 4 4 Replacing worn parts 10 4 5 Commonly reported problems 11 Chemical Compatibility Table 12 WARRANTY CERTIFICATE 13 Dimensions 14 Connection and exploded views 15...

Page 4: ...rical plant has to be in conformity with the rules of the country where it is realised The room temperature of utilisation can t over take 45 C 1 2 Shipping and transporting the pump The equipment must be transported in its original packaging organized and built in such a way as to minimize shocks and to protect the protruding parts that can be damaged If there is a need for transport after the eq...

Page 5: ...ves endowed with CE mark in conformity with the following European directives n 2014 30 CE Electromagnetic compatibility ECM n 2014 35 CE DBT Low Voltage Directive e s m i n 2011 65 UE 2012 19 UE direttive RoHs e WEEE e s m i Granted this we think that in order to obtain an high trustworthiness and a lasting functioning of the pump it is necessary to follow with attention our manual particularly i...

Page 6: ... programming is based on setting of number of pulses per minutes The number of pulses per minutes will change the flow rate of the pump It is possibile to modify the number of pulses per minutes using 2 range Complete 0 100 Reduced 0 20 To change the range of trimmer proceed as follow Put the trimmer at minimum 0 Flashing frequency indicates the actual dosing range fast flashing 0 100 slow flashin...

Page 7: ...th the applicable regulations Ensure the unit is connected to a circuit protected by a highly sensitive 0 03A RCCB circuit breaker If unsure please consult a competent electrician Verify that the rated values of the pump are compatible with those of the mains Never install the pump directly in parallel with inductive loads e g motors solenoid valves if necessary use an isolating relay There are 2 ...

Page 8: ...lyetilene on the hose clamp of the nipple s valve lock everything by closing the nut well Connect the other extremity to the delivery of the pump upper part of the pump head by repeating the instructions above See fig 9 Purge connect another tube s extremity for the manual purge 2 mt PVC crystal in the hose clamp situated on the pump head lower to the right while the other extremity is to be put i...

Page 9: ...e compatibility tables or our technical department Dimensions Series HC899 pump wall mounting Fig 1 Series HC899 pump base mounting Fig 2 Connection and exploded views Tubing connections on pump head Fig 9 Manual purge Fig 10 Low level switch connection HC899 Fig 11 HC899 series exploded view Fig 16 HC899 Pump head ball Fig 17 Fig 19 4 0 MAINTENANCE 4 1 General maintenance comments Regular mainten...

Page 10: ...tion the technical and safety characteristic of the dosing chemicals and follow the next procedures 1 Turn off the pump and immerse the foot filter and the injection tube in clean water Turn on the pump to let the water go through the pump head If there are some crystals to be cleaned follow the next procedures 2 Immerse the foot filter and the injection tube into an adequate solution to remove th...

Page 11: ... Caution do not over tighten We also recommend adding a few drops of Loctite 222 on to the thread of the screws that hold the head 4 5 Commonly reported problems THE PUMP DOES NOT FUNCTION AND THE GREEN LED IS NOT LIT Solutions 1 Check that the electrical connection is correctly made 2 Check that the fuse has not blown 3 Replace the electronic circuit with a new one THE PUMP FUNCTION CORRECTLY BUT...

Page 12: ... 1 Sulphuric acid 98 5 H2SO4 1 1 3 3 1 1 1 3 3 3 Amines R NH2 1 2 1 3 1 1 3 2 3 1 Sodium bisulphite NaHSO3 1 1 1 1 1 1 1 1 1 1 Sodium carbonate Soda Na2CO3 2 1 1 1 1 1 2 1 1 1 Iron chloride FeCl3 1 1 1 1 1 1 1 1 1 1 Calcium hydroxide Ca OH 2 1 1 1 1 1 1 1 1 1 1 Sodium hydroxide Caustic soda NaOH 2 1 1 1 1 1 2 1 2 1 Calcium hypochlorite Ca OH 2 1 1 1 1 1 1 1 1 3 1 Sodium hypochlorite 12 5 NaOCl NaC...

Page 13: ...r the parts directly or through authorised workshops It remains anyway excluded from whatever responsibility and obligation for others costs damages and direct or indirect losses that come from the use or the not use availability either total or partial The reparation or the supply in substitution will neither extend nor renew the period of guarantee They remain anyway at charge of the purchaser t...

Page 14: ...ANDMONTAGE НАСТЕННЫЙ Fig 2 SERIE HC899 CON BASE BASE MOUNTING VERSION AVEC BASE VERSION CON SOPORTE PARA MONTAJE ORIZONTAL MIT BASIS С ПОДСТАВКОЙ DIMENSIONI DIMENSIONS DIMENSIONS DIMENSIONES ABME DIMENSIONI DIMENSIONS DIMENSIONS DIMENSIONES РАЗМЕРЫ DIMENSIONI DIMENSIONS DIMENSIONS DIMENSIONES ...

Page 15: ...DE MONTAJE CONNEXIONESTERNAS SCHLAUCHANSCHLÜSSE AM PUMPENKÖRPER СОЕДИНЕНИЯ ШЛАНГОВ НА ГОЛОВКЕ НАСОСА Fig 2 SPURGO MANUALE MANUAL PURGE EPURGE MANUELLE ESPURGO MANUAL MANUELLE SPÜLUNG РУЧНОЙ СЛИВ COLLEGAMENTI ED ESPLOSI CONNECTION AND EXPLODED VIEWS CONNECTIONS ET EXPLOSE DIBUJOS ANSCHLÜSSE UND EXPLOSIONSZEICHNUNGEN СОЕДИНЕНИЯ И ЧЕРТЕЖИ ...

Page 16: ...DE MONTAJE SONDA DE NIVEL OPTIONAL ANSCHLUSS DER NIVEAUSONDE ПОДСОЕДИНЕНИЕ ДАТЧИКА УРОВНЯ ДОПОЛНИТЕЛЬНАЯ ОПЦИЯ Fig 4 HC997 999 COLLEGAMENTO SONDA DI LIVELLO LOW LEVEL PROBE CONNECTION SCHÉMA DE MONTAGE SONDE DE NIVEAU ESQUEMA DE MONTAJE SONDA DE NIVEL OPTIONAL ANSCHLUSS DER NIVEAUSONDE ПОДСОЕДИНЕНИЕ ДАТЧИКА УРОВНЯ ДОПОЛНИТЕЛЬНАЯ ОПЦИЯ ...

Page 17: ...05 02 2021 Rev 1 17 Fig 5 SERIE HC 899 Esploso Description Explose Dibujo Explosionszeichnung ртеж ...

Page 18: ...PO POMPA 1 14LT HC897 1 15 ADSP5007072 OR R1 NBR 2 60X1 90 2 16 ADSP6000708 VITE M 4 X 8 UNI 7688 AF TSTC INOX A2 2 17 ADSP9000035 GUARNIZIONE COPERCHIETTO ALIMENTAZIONE HC999 GOMMA NBR 1 18 ADSP6000503 INTERRUTTORE BIPOLARE 250V A BILICO SIMBOLO 1 0 CON PROTEZIONE IN GOMMA 1 19 ADSP9300025 COPERCHIO CONNETTORI HC999 ARNITE NERA 1 20 ADSP6000887 VITE M 3 5 X 22 UNI 6954 AF TCTC INOX A2 4 21 ADSP60...

Page 19: ...Corpo pompa valvole a labbro e sfera Pump head lip and ball valves Corps pompe et clapets à lèvres et bille Cuerpo de la bomba valvulas a labio y a esfera Pumpenkörper Lippen und Kugelventile Головка насоса губчатый и шариковый клапан ...

Page 20: ...ERO 1 8 ADSP6000785 PORTAGOMMA SPURGO CORPO POMPA PP 1 9 ADSP5007072 OR R1 2 60X1 90 NBR 1 10 ADSP6200006 OR RIF 2018 VITON NERO 1 11 ADSP9000004 STELO OTTURATORE PER SPURGO CORPO POMPA HC897 PP 1 12 ADSP9000005 GHIERA 1 4 PER SPURGO CORPO POMPA HC897 PP 1 13 ADSP6000701 RONDELLA PIANA D 5 UNI 6592 INOX A2 6 14 MB010700 TCEI UNI5931 VITE M 5 X 40 UNI 5931 TCEI INOX A2 00 00 00 0000 6 15 ADSP930004...

Page 21: ... RACCORDO TUBO 10X14 G3 4 PVC PER VALVOLA SFERA 2 4 ADSP5004002 GHIERA FISSATUBO PP NERA 1 2 10X14 2 5 ADSP6000805 RONDELLA D 4 4 3 x 10 4 x 1 INOX A2 6 6 ADSP6000723 VITE M 4 X 35 UNI 5931 TCEI INOX A2 6 7 ADSP5007044 OR RIF 3287 VITON NERO 1 Fig 9 Corpo pompa alte portate High flowrate Pump head Corps pompe à débit élevé Cuerpo de la bomba de alto caudal Pumpenkopf mit hoher Durchflussrate Напор...

Page 22: ... del 25 07 2005 Col riciclo e re utilizzo del materiale e altre forme di utilizzo di dispositivi obsoleti si può rendere un importante contributo alla protezione dell ambiente Note on environmental protection After the implementation of the European Directive 2002 96 EU in the national legal system the following applies Electrical and electronic devices may not be disposed of with domestic waste C...

Page 23: ...05 02 2021 Rev 1 23 HC 899 ...