NOTE
Fan speed settings
Air dehumidifIers
11
Timer ON setting
After enter the timer setting status,
the value is flashing, press and
to set timer ON/OFF, value range
1~24.
Set the value, and wait for 15
seconds, setting is saved.
The timer setting will be eliminated
after disconnected from electricity
or power failure, in this case, timer
should be reset after the recovery
of electricity.
Turn off the dehumidifier
Press to turn off the dehumidifier,
LCD displayed as below figure:
Key composite function
Press the "
△"
key and "
▽"
key
for 3 seconds to turn on / off
keyboard lock.
Starting the unit, press to
change the fan speed.
b. Timer ON must be set under
standby status. Press to enter
timer ON setting status, LCD
shows as below:
Parameter query and set
1
2
3
4
5
6
7
C1
C2
C3
C4
C5
C6
C7
Heating function
Condensation (coil)
temperature
Humidity sensor detects
deviation
Press after opening delay
detection time
Enter the defrost point
temperature
Exit defrost point temperature
Maximum defrost time
Parameter
Description
Default
values
Code Meaning
Para-
meter
No.
0~1
1
-20~99
℃
—
5
%~
5
%
0
%
20
~
90min
40
-
10
~
10
℃
-
1
0
℃~
15
℃
8
2
~
12min
8
Press the
3
seconds to enter the parameter query set menu
parameters as follows:
Press the , the parameter values in to display C1 and C3
when flashing
▲
and
▼
keys to set parameter values. Press key to
exit the settings.
Fault protection code
1
2
3
4
5
6
7
Room temperature sensor failure
Coil temperature sensor failure
Humidity sensor failure
High-pressure protection
Flow switch failure
Phase sequence failure
Screen display
Protection / failure
No.
E1
E2
E3
E4
E5
E6
E8
Press the
3
seconds to enter the parameter query set menu
parameters as follows:
Low-pressure protection
8
Communication failure
EE