background image

AQUACAL

 

 

 

 

Polyphosphate salt feeder

 

 

ENGLISH

 

L0200080 

rev. 1.0  

 

23/10/2020 

 

 

 

2/10

 

 

 

 

Summary of Contents for AQUACAL 1/2

Page 1: ...L0200080 rev 1 0 23 10 2020 1 10 INSTALLATION USE AND INSTRUCTION MANUAL AQUACAL AQUACAL R ...

Page 2: ...AQUACAL Polyphosphate salt feeder ENGLISH L0200080 rev 1 0 23 10 2020 2 10 ...

Page 3: ...e salt feeder ENGLISH L0200080 rev 1 0 23 10 2020 3 10 INDEX 1 WARNINGS 4 2 USE 4 3 HYDRAULIC CONNECTION 5 4 MAINTENANCE 6 4 1 PREPARATION OF POLYPHOSPHATE Errore Il segnalibro non è definito 5 TECHNICAL CHARACTERISTICS 7 ...

Page 4: ...e heated favors a chemical reaction and the subsequent precipitation of magnesium and calcium carbonate as well as carbon dioxide Carbon dioxide favors the corrosion of pipes while calcium carbonate precipitates deposits of limestone Without actually removing the limestone through the use of the proportional dosers of AQUACAL polyphosphate salt an adequate anti scale and anti corrosion treatment o...

Page 5: ... the reintegration of polyphosphate salt can be carried out simply by positioning the black levers horizontally The same in fact have by pass functionality All models can be mounted both in systems with vertical and horizontal pipes changing the orientation of the connection nipple To change the orientation of the nipple follow the instructions below 1 Unscrew the connecting screws 2 Rotate the ni...

Page 6: ...the vessel using the vent screw 4 unscrew the jar FIG C 5 replenish the polyphosphate 6 contract the bellows 7 screw the jar paying attention to the correct O Ring positioning FIG E 8 tighten the vent screw FIG C 9 open the taps BC FIG A 10 close the tap A FIG A AQUACAL R 1 lift the levers FIG D 2 depressurize the vessel using the vent screw 3 unscrew the jar FIG C 4 replenish the polyphosphate 5 ...

Page 7: ...the cap If the casing is also removed the tablet will dissolve faster as the water touches a greater surface of salt 6 CAUTIONS IN THE USE OF SALT The polyphosphate salt does not eliminate limestone It acts by creating a film that protects the pipes the exchangers and the tanks from the gripping action of the limestone which therefore does not cling to the surfaces and flows with the water coming ...

Page 8: ...AQUACAL Polyphosphate salt feeder ENGLISH L0200080 rev 1 0 23 10 2020 8 10 7 DIMENSIONI DIMENSION AQUACAL AQUACAL R 1 2 AQUACAL 1 ...

Page 9: ...EATURES DATI TECNICI TECHNICAL DATA Testa Head PP Attacco Connection Ottone Brass Vaso Sump SAN Soffietto Bellow EPDM Oring Oring EPDM Pressione max esercizio Max working pressure 6 bar Pressione max scoppio Max burst pressure 25 bar Temp Acqua max consigliata Max operating temp Water 25 C Dosaggio Feeding 2 4 ppm ...

Page 10: ...AQUACAL Polyphosphate salt feeder ENGLISH L0200080 rev 1 0 23 10 2020 10 10 AQUACAL AQUACAL R ...