Safety
10 EN
06|2019
Seized pump
If a pump seizes, and is switched on several times repeatedly, the
motor can be damaged. Observe the following points:
Do not switch the pump/unit on repeatedly.
Turn the motor shaft by hand. See point 5.1 on page 21.
Clean
pump.
2.9 Preventing
material
damage
2.9.1 Dry
running
If run dry, mechanical seals and synthetic parts can be destroyed
within only a few seconds.
Do not allow the pump to run dry. This also applies to
checking the rotation direction.
Purge air from pump and suction line prior to start-up.
2.9.2 Cavitation
Pipes which are too long increase resistance. This results in risk
of cavitation.
Observe the maximum pipe length.
2.9.3 Overheating
The following factors can result in the pump overheating:
• Ambient
temperature
which is too high
Do not exceed the permitted ambient temperature of 40 °C.
2.9.4 Blockages
in
the
pump
Pieces of dirt in the suction line can clog and block the pump.
Do not operate the pump without a strainer basket or a
strainer basket handle.
Check how easily the pump rotates before starting it up and
after longer idle or storage periods.
2.9.5 Risk
of
frost
Drain the pump/unit and pipes at risk of freezing in plenty of
time.
Remove the pump/unit during periods of frost and store it in a
dry room.
Summary of Contents for AQUA Master Series
Page 15: ...Beschreibung 06 2019 DE 13 WG26 30 009 P Abb 2...
Page 38: ......
Page 51: ...Description 06 2019 EN 13 WG26 30 009 P Fig 2...
Page 74: ......
Page 88: ...Description 14 FR 06 2019 WG26 30 009 P Fig 2...
Page 124: ...Beschrijving 14 NL 06 2019 WG26 30 009 P Afb 2...
Page 159: ...Popis 06 2019 CS 13 WG26 30 009 P Obr 2...
Page 182: ...36 06 2019...