Safety
06|2019
EN
9
2.7.3 Electrical
energy
There is an increased risk of electric shock when working on the
electrical system due to the humid environment.
Electrical protective earth conductors which were not installed
correctly can also result in electric shocks, for example due to
oxidation or cable breakage.
Observe VDE and utility company regulations.
Build swimming pools and their protection according to
DIN VDE 0100-702.
Before working on the electrical system, take the following
measures:
– Disconnect
system
from the power supply.
– Attach
a
warning
sign: “Do not switch on! The system is
being worked on.”
– Ensure
that
the
system is free of voltage.
Check the electrical system regularly to ensure it is in proper
working condition.
2.7.4 Hot
surfaces
The electric motor can reach temperatures of up to 70 °C. There
is a risk of being burned.
Do not touch the motor during operation.
Allow the pump/unit to cool down before servicing it.
2.7.5 Suction
danger
Due to a small suction surface, there is a danger of people, long
hair or other objects being sucked in.
Fit the suction area according to DIN EN 13451 and the data
sheet 60.03 “Safeguarding of discharge lines against
pressing forces” published by the German Society for the
Bathing Industry (Deutschen Gesellschaft für das
Badewesen).
2.8 Faults
In case of a fault, immediately switch the pump off and
remove it from operation.
Have all faults repaired immediately.
Summary of Contents for AQUA Master Series
Page 15: ...Beschreibung 06 2019 DE 13 WG26 30 009 P Abb 2...
Page 38: ......
Page 51: ...Description 06 2019 EN 13 WG26 30 009 P Fig 2...
Page 74: ......
Page 88: ...Description 14 FR 06 2019 WG26 30 009 P Fig 2...
Page 124: ...Beschrijving 14 NL 06 2019 WG26 30 009 P Afb 2...
Page 159: ...Popis 06 2019 CS 13 WG26 30 009 P Obr 2...
Page 182: ...36 06 2019...