© 2002 New Aqua LLC dba Aqua Systems • 7785 East US Hwy 36 • Avon, IN 46123
12
Series SC
Installation, Operation,and
Maintenance Manual
Start Up
Put Unit into Service:
1. Add 6” of water to the brine tank (if tank has a salt shelf,
about 1” above shelf).
2. Plug the transformer into a 110 volt receptacle. The control
will place itself in the”Softening” mode and will flash 12:00
on the display.
3. Set the current time of day. (
see page 13 )
4. Push and hold the “REGEN” button for 3 seconds. The
system will advance to the “Backwash” position.
5. Slowly open the inlet to the bypass. (
see page 8, figure 3
)
6. Water will run to the drain. Let it run 5 minutes or until the
the water to drain is clear.
7. Push “ REGEN” button and release. The control will
advance to the “BRINE” position. Let cycle run for several
minutes to confirm the water is removed from the brine tank
to a level below the salt shelf.
8. Push “ REGEN” button and release. (see note at right) The
control will advance to the next cycle. Keep pushing
“REGEN” button until the control reaches the “FILL” position.
Let the control complete this cycle automatically to fill the
brine tank to the proper level. The control will then return to
the service (“SOFTENING”) position.
9. When the control has reached the service position, fill the
brine tank with salt. Open the outlet handle on bypass.
(
see page 8, figure 1
)
10. Proceed to the Programming instructions. After program
ming, the system should be disinfected.
To Disinfect the System:
1. Add 1.2 fluid ounce of 5.25% sodium hypochlorite solution
(household bleach; Clorox, Bo Peep, etc.) for each cubic
foot of resin to the brine well of the brine tank. ( the 4” tube
with a cap on it inside of the brine tank)
2. Press “REGEN” for 3 seconds to start a normal regenera-
tion. Allow the system to complete the regeneration.
Make sure that the electrical outlet used
is an uninterrupted outlet (such as outlet
that is operated by a switch).
All electrical connections must be connected
according to local codes.
Note:
When pushing the “REGEN” button to
advance cycles, let the control reach the
next cycle before pushing the “REGEN”
button again.
Note:
The materials of construction of the modern water
conditioner will not promote bacterial growth, nor
will these materials contaminate a water supply.
However, the normal conditions that exist during
shipment, storage and installation make it advis-
able to disinfect a conditioner after installation,
before the conditioner is used to treat potable
water. In addition, during normal use, a conditioner
may become fouled with organic matter, or in some
cases, with bacteria from the water supply. There-
fore every conditioner should be disinfected after
installation, some will require periodic disinfection
during their normal life.
Disinfection: